xray circuit

0.0(0)
studied byStudied by 0 people
0.0(0)
full-widthCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/45

encourage image

There's no tags or description

Looks like no tags are added yet.

Study Analytics
Name
Mastery
Learn
Test
Matching
Spaced

No study sessions yet.

46 Terms

1
New cards

primary, secondary, filament

3 primary sections of the xray circuit

2
New cards

primary circuit

consists of the main power switch (connected to
the incoming power supply), circuit breakers, the autotransformer, the timer circuit, and the primary side of the step-up transformer

3
New cards

secondary circuit

consists of the secondary side of the step-up
transformer, the mA meter, a rectifier bank, and the x-ray tube (except
for the filaments).

4
New cards

filament circuit

a rheostat, a step-down transformer, and the filaments

5
New cards

main power switch

simply an on-off switch for the unit and is connected to the power supply of the facility

6
New cards

line compensator

wired autotransformer that automatically adjusts the power supply to keep it at 220 volts

7
New cards

circuit breaker

protects against short circuits and electric shock

8
New cards

autotranformer

adjustable transformer controlled by the kVp selector on the operation console

9
New cards

step-up transformer

used to increase the voltage from the autotransformer to the kilovoltage necessary for xray production 

10
New cards

step-up transformer

this is the divivding line between the primary and secondary circuit

11
New cards

timer circuit

exposure timer that makes it easier to control a low voltage than and very on

12
New cards

secondary circuit

consists of the secondary side of the step-up transformer, the mA meter, a rectifier bank, and the x-ray tube (except for the filaments)

13
New cards

filament circuit

consists of a rheostat, a step-down transformer, and the filaments.

14
New cards

mA meter

a device placed in the secondary circuit that monitors x-ray tube current

15
New cards

rectifiers

converts ac to dc in the secondary unit

16
New cards

anode to cathode

in the xray tube current must flow from….

17
New cards

solid state rectifier

rectifier commonly used in todays xray circuit that is made of 2 semi conducting crystals (p-type and n-type)

18
New cards

rheostat

begins the filament circuit and is controlled by the mA selector

19
New cards

mA

“tube current” that reflects the rate of flow of electrons passing through the xray tube during an exposure

20
New cards

exposure timer

works in concert with the rheostat

21
New cards

rheostat

controls filament temperate and the rate at which electrons are boiled off of the filament

22
New cards

exposure timer

determines the duration of the rheostat

23
New cards

together these two determine the quantity of electrons boiled off of the filament 

24
New cards

step-down transformer

used in the filament circuit to increase the current by reducing the voltage that is applied to the filament

25
New cards

filaments

the final piece of the filament circuit

26
New cards

small focal spot

there are 2 filaments one signifying a large focal spot and a

27
New cards

boil off electrons

the goal of the filament circuit is to ….. out of the filament wire

28
New cards

5-7

a large filament current of …. amps is required to produce a tube current in the range of milliampres

29
New cards

thermionically emitted electrons

…. are needed for xray production and represent one more step in our manipulation of electricity 

30
New cards

filament circuit

in this circuit we are boiling off electrons off a very small wire and must precisely control the current that is applied

31
New cards

damaged

if the current is too high on the small wire of the filament circuit, the tiny wire will be

32
New cards

kVp

this adjusts the autotransformer and determines the number of turns on the secondary side necessary to produce a voltage throught self induction

33
New cards

step up….mutual induction

the …. transformer increases this voltage by a fixed amount and
through ….. produces the kilovoltage selected on the
operating console

34
New cards

solid state rectifiers

used to route electricity through the xray tube correctly

35
New cards

technique

the process begins when the radiographer selects a

36
New cards

anode, cathode

After passing through the rectifiers, the electricity creates a large
positive charge on the ….. of the x-ray tube and a large negative
charge on the ….. focusing cup

37
New cards

filament circuit, rheostat

the ……. draws electricity from the autotransformer, which then travels to the …..

38
New cards

step down transformer

from the rheostat, electricity then travels to the

39
New cards

filament

the adjusted current from the step down transformer then travels directly to the …. 

40
New cards

focusing cup

the filament is located with in the

41
New cards

boiled off

the filament heats up to the point where the electrons are boiled off

42
New cards

cloud of electrons

the filament circuit creates a

43
New cards

anode, cathode

the kilovoltage applied to the xray tube created a large positive charge on the …. and a large negative charge on the ….

44
New cards

kinetic energy

the large positive change attracts the electrons boiled off, giving them

45
New cards

crowded together

the large negative charge on the cathode serves to keep the electrons…

46
New cards

timer circuit

The electrons travel across to the anode and interact there to produce x-rays until the …. terminates the process