The architect registered and licensed under R.A. No. 9266, who is directly and professionally responsible for the total design of the project for the client and who shall assume the civil liability for the plans, specifications and contract documents he/she has signed and sealed.
Architect-of-Record
The architect registered and licensed or permitted to practice under R.A. No. 9266, who is professionally and academically qualified and with exceptional or recognized expertise or specialization in any branch of architecture.
Consulting Architect
Existing Organization in the Philippines
Integrated and Accredited Professional Organization
It refers to the intellectual proprietary rights retained by an Architect over any architectural documents/ work that he/she prepares unless there is a written stipulation to the contrary.
Copyright
Involves the detailed planning and design of the indoor/enclosed areas of any proposed building/structure, including retrofit, renovation, rehabilitation or expansion work which shall cover all architectural and utility aspects, including the architectural lay-outing of all building engineering systems found.
Architectural Interiors
Which is the scope of the SPP 204-A?
Evaluation of Construction Work
Which is the scope of the SPP 204-B?
Cost and Time Control
Professional that will sign the Certificate of Completion of a project
Architect in charge of construction
Described as a medium density * usually 3-5 floors, multiple family dwelling
Max R-2
ISA + USA
TOSL
PSO + TOSL
TLA
PSO + ISA
MACA
AMBF / TLA
PSO
It is allowed to have abutment on one (1) side of R-1 lots
TRUE
A certificate bearing a registration number, issued to an individual, by the Professional Regulation Commission through the Board of Architecture, signifying that the individual has successfully passed the Licensure Examination and is registered to practice his/her profession as Architect;
COR
Handrails for PWD
900mm and 700mm
Workstations designed for accessibility shall ensure each
900mm
Years of Civil Liability of Architects
15
Door opening min. width means of egress
710mm
Architect shall respect and help conserve the systems of values and the natural, historic, and cultural heritage of the community in which he/she creates architecture.
Responsibility to the People
Architects’ responsibility without undue delay and reasonable time limit.
Responsibility to the Client
Architects’ responsibility for Basic Minimum Fee in the SPP documents. (double check question)
Responsibility to his Colleagues
Architects’ responsibility shall not render professional services without a professional service agreement.
Responsibility to his Colleagues
Turnabout spaces in dead end corridors for accessibility.
3500mm
Means an architectural drawings, specifications, and other outputs of an Architect that only an Architect can sign and seal consisting, among others, of vicinity maps, site development plans, architectural program, perspective drawings, architectural floor plans, elevations, sections, ceiling plans, schedules, detailed drawings, technical specifications and cost estimates, and other instruments of service in any form;
Architectural Documents
Responsbilities of the PRBOA
Supervise the registration, licensure and practice of architects;
Which is correct?
Both are correct
Which cannot be constructed on public sidewalk?
Both A and B
Student from Switzerland came home to Philippines but calls himself Architect on social media even though he is yet to take the board exam.
Section 25
Signing of architectural drawings by another person.
Section 32
Did Mr. ABC pass or fail the ALE. He scored 49% in one subject and the rest are above 50% with almost line of 9s. (non-verbatim)
Mr. ABC failed (49%)
Ms. DFE convicted of political crime while waiting for the oathtaking.
Refusal of COR and PIC
Maximum slope of ramp if riser is 650mm.
1:15
Maximum slope of ramp if riser is 750mm.
1:20
Compensation of the architect if the project is 15,500,000?
1,550,000
Minimum Temporary Sidewalk Width
1200mm
Maximum distance of entrance to accessible elevator
30m
Scope of the Practice of Architecture
Both A and B
Means a document embodied in the Architects National Code, which defines all aspects of professional service, prescribes minimum basic fees and establishes the rights and obligations of both the Architect and the client;
SPP
Means a document which forms part of the Architects’ National Code which contains the norms and principles governing the practice of the profession of architecture in the highest standards of ethical conduct;
Code of Conduct
A continuous and unobstructed route of exit from one point in a building, structure or facility access and exit discharge.
Means of Egress
(solving)
Inside Lot 336 sqm R-2 12m RROW
What is the AMBF after setbacks?
230
(solving)
Inside Lot 336 sqm R-2 12m RROW
If the PSO of R-2 is 60, what is the TOSL?
134.4
(solving)
Inside Lot 336 sqm R-2 12m RROW
What is the MACA?
302.4
(solving)
Inside Lot 336 sqm R-2 12m RROW
What is the minimum USA
33.6
(solving)
Inside Lot 336 sqm R-2 12m RROW
Firewall?
22.4
The RPF % of an architect in the total PCC rendering Design-Build Services in section 207 of SPP?
7%