ALE- PHILIPPINE GREEN BUILDING CODE

0.0(0)
studied byStudied by 0 people
0.0(0)
full-widthCall with Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/99

encourage image

There's no tags or description

Looks like no tags are added yet.

Study Analytics
Name
Mastery
Learn
Test
Matching
Spaced
Call with Kai

No study sessions yet.

100 Terms

1
New cards

The GB Code shall be subject to the following performance standards:

Energy Efficiency

Water Efficiency

Material Sustainability

Solid Waste Management

Site Sustainability

Indoor Environmental Quality

2
New cards

WWR

Window to Wall Ratio

3
New cards

Solar Heat Gain Coefficient (SHGC)

used to determine the amount of solar heat admitted through the glass divided by the total solar radiation incident on the glass.

4
New cards

Operable windows or balcony door shall be provided in regularly occupied spaces. The size of the opening shall be equal to at least _________?

(10%) of the floor area of regularly occupied spaces.

5
New cards

Solar Reflectance Index (SRI)

Light-colored building envelope, especially the roof areas which are the most vulnerable, can reduce heat transfer from the outside to the inside of the building by having surfaces with high ____________________________?

6
New cards

Reflective white

86 to 92 SRI

7
New cards

Basic white

80 to 88 SRI

8
New cards

Beige / Tan

74 to 80 SRI

9
New cards

Dark brown

0 to 33 SRI

10
New cards

Light to medium brown

45 to 56 SRI

11
New cards

Light to medium grey

39 to 63 SRI

12
New cards

Dark grey

0 to 41 SRI

13
New cards

Blue

23 to 30 SRI

14
New cards

Light to medium blue

35 to 38 SRI

15
New cards

Red

28 to 36 SRI

16
New cards

Terracotta red

38 to 40 SRI

17
New cards

Green

25 to 32 SRI

18
New cards

Light to medium green

30 to 48 SRI

19
New cards

Buildings shall be provided with roof insulation so that the average thermal resistance value (R-Value) of the roof is at least ______?

R-8

20
New cards

Polyisocyanurate

R- 5.6 to 8.0

<p>R- 5.6 to 8.0</p>
21
New cards

Polyisocyanurate

best insulator

<p>best insulator</p>
22
New cards

Polyurethane insulation

R-5.6 to 6.5

23
New cards

Closed cell spray foam

R-5.5 to 6.0

<p>R-5.5 to 6.0</p>
24
New cards

Vermiculite / Perlite

The most common spray-applied fire-resistive materials (SFRMs) are mineral fiber or expanded aggregate coatings such as _____. Degree of protectiveness depends on material and thickness.

<p>The most common spray-applied fire-resistive materials (SFRMs) are mineral fiber or expanded aggregate coatings such as _____. Degree of protectiveness depends on material and thickness.</p>
25
New cards

Vermiculite / Perlite

R-2.4

26
New cards

Reflective bubble foil

R-1 to 1.1

27
New cards

Transformers that are part of the building electrical system shall have efficiencies not lower than ________ as prescribed in the DOE Guidelines on Energy Conserving Design of Buildings.

98%

28
New cards

Recycled water from Sewage Treatment Plants (STP) shall be reused for ________________________

non-potable purposes.

29
New cards

Non-Toxic building materials

refer to building materials without hazardous or toxic chemicals that could cause Sick Building Syndrome (SBS) and eventually lead to Building Related Illness (BRI).

30
New cards

Volatile Organic Compounds (VOC)

Chemical-emitting gases or solids from interior products and materials that can cause short-term or long-term adverse health effects.

31
New cards

Solid waste containers shall be provided for at least four (4) types of wastes:

- compostable (biodegradable)

- non-recyclable (to be disposed off in the landfill)

- recyclable (paper, cardboard, plastic, metal, wood, etc.)

- special waste

32
New cards

Material Recovery Facility (MRF)

a plant where collected recyclables are sorted and prepared for reprocessing

33
New cards

RA 9211, the Tobacco Regulations Act,

Environmental Tobacco Smoke (ETS) is one of the leading causes of respiratory illnesses in building occupants. _____________________________ restricts tobacco smoking in public spaces and the prescription of designated smoking areas inside buildings.

34
New cards

PSVARE

Philippine Society of Ventilating, Air-Conditioning and Refrigerating Engineers

35
New cards

Air Conditioning

the process of treating air so as to control simultaneously its temperature, humidity, cleanliness, and distribution to meet the requirements of conditioned space

36
New cards

British thermal unit (Btu)

- amount of heat energy needed to raise the temperature of one pound of water by one degree Fahrenheit

37
New cards

Building Related Illness (BRI)

diagnosable illness whose cause and symptoms can be directly attributed to a specific pollutant source within a building

38
New cards

Energy Efficiency Ratio

energy efficiency rating for room air conditioners that lists how many Btu per hour are used for each watt of power it draws

39
New cards

Heating, Ventilating and Air Conditioning (HVAC)

- system that helps maintain good indoor air quality through adequate ventilation with filtration and provide thermal comfort

40
New cards

Light Shelf

a horizontal surface that reflects daylight deep into a building, placed above eye-level with high-reflectance upper surfaces, which reflect daylight onto the ceiling and deeper into the space

<p>a horizontal surface that reflects daylight deep into a building, placed above eye-level with high-reflectance upper surfaces, which reflect daylight onto the ceiling and deeper into the space</p>
41
New cards

R-Value

resistance value or the capacity to resist heat loss or its thermal resistance

42
New cards

Seasonal Energy Efficiency Ratio (SEER)

energy efficiency rating for central air conditioners

43
New cards

Sick Building Syndrome (SBS)

Building whose occupants experience acute health and/or comfort effects that appear to be linked to time spent therein, but where no specific illness or cause can be identified

44
New cards

Solar Reflectance Index (SRI)

a measure of a material's ability to reflect heat with white or light colors having high reflectance and dark or black surfaces with low or little reflectance thereby having higher temperatures

45
New cards

U-Value

describes how well a building element conducts heat, measuring the rate of heat transfer through a building element over a given area, under standardized conditions

46
New cards

Volatile Organic Compound (VOC)

organic chemicals with have a high vapor pressure at ordinary room temperature that are dangerous to human health or cause harm to the environment

47
New cards

Weather-Stripping

narrow piece of material, such as plastic, rubber, felt, or metal, installed around doors and windows to protect an interior from external extremes in temperature.

48
New cards

FIBERBOARD - 1/2 inch [12.5mm]

R-1.32

49
New cards

i. Window

ii. Light shelf

iii. Clerestory

iv. Skylight

v. Light monitor / light scoop

vi. Other devices that can allow daylight inside

All regularly occupied spaces inside the building shall have a view of any combination of the following features that can allow daylight into the room space:

50
New cards

LPD Lighting Power Density

Installed lighting power per unit area

51
New cards

Building Related Illness

What does BRI stands for?

52
New cards

Sick Building Syndrome(SBS)

What does SBS stand for?

53
New cards

50%

Air conditioning typically accounts for more than ____ % of total electricity costs in a centrally air conditioned building.

54
New cards

Polyisocyanurate

Insulation material with the highest R-value.

55
New cards

Reflective bubble foil

Insulation material with the lowest R-value.

56
New cards

Dark brown

Metal Surface color with the lowest SRI

57
New cards

Reflective white

Metal Surface color with the highest SRI

58
New cards

Variable Speed Drive

An electrical device for controlling the speed of a DC motor, or a mechanical device used to control the speed of a piece of equipment driven by a constant speed motor.

59
New cards

5 kW

All motors for mechanical equipment over _____ kW shall be provided with variable speed drive and high efficiency motors.

60
New cards

Kitchen Ventilation Fans

These are exempt from Variable Speed Drives and High Efficiency Motors.

61
New cards

60%, 90%

All buildings with centralized air supply system shall use enthalpy recovery wheels with efficiency of at least ____ % of ____ % exhaust air.

62
New cards

Enthalpy recovery wheels

All buildings with centralized air supply system shall use ___________ with efficiency of at least sixty percent (60%) of ninety percent (90%) exhaust air.

63
New cards

1/2

The photoelectric sensor shall be located approximately at _____ the depth of daylight zone

64
New cards

10.8

Building Average Lighting Power Density (LPD) for Residential Dwelling: Condominium. (W/m2)

65
New cards

10.8

Building Average Lighting Power Density (LPD) for Hotel/ Resort (W/m2)

66
New cards

12.9

Building Average Lighting Power Density (LPD) for Educational: School (W/m2)

67
New cards

12.9

Building Average Lighting Power Density (LPD) for Institutional: Hospital (W/m2)

68
New cards

10.8

Building Average Lighting Power Density (LPD) for Business: Office (W/m2)

69
New cards

16.1

Building Average Lighting Power Density (LPD) for Mercantile: Mall (W/m2)

70
New cards

60%

For covered car parks: minimum of ___ % of the lighting must be controlled by the occupancy sensors.

71
New cards

1 1/12

Escalators / Moving Ramps / Walkways shall be fitted with automated controls to reduce to a slower speed when no activity has been detected for a maximum period of ________ minutes and duration may be adjusted depending on the demand.

72
New cards

5 minutes

The escalator / moving ramp / walkway shall automatically be put on a standby mode when no activity has been detected for a maximum period of ______ minutes and duration may be adjusted depending on the demand.

73
New cards

55

Use of energy efficient lighting and display lighting in the elevator car shall have an average lamp efficacy, across all fittings in the car, of more than _____ lumens / watt

74
New cards

98%

Transformers that are part of the building electrical system shall have efficiencies not lower than _____% as prescribed in the DOE Guidelines on Energy Conserving Design of Buildings.

75
New cards

20%

To reduce dependence on motorized systems to supply and distribute potable or non-potable water within the building, thus help reduce energy consumption, overhead or elevated water storage systems are used, provided there's a _____ % fire reserve over and above the average daily demand supply.

76
New cards

10

Buildings below ____ storeys high are exempt from Overhead or Elevated Water Storage provision to reduce dependence on motorized systems.

77
New cards

6 liters/ flushing cycle

Maximum Flow Rate of Dual Flush Water Closet

78
New cards

4.9 liters/ flushing cycle

Maximum Flow Rate of Single Flush Water Closet

79
New cards

9 liters/ min. at 551.6 kPa

Maximum Flow Rate of Shower

80
New cards

1 liter/ flushing cycle

Maximum Flow Rate of Urinals

81
New cards

4.8 liters/ min. at 417.7 kPa

Maximum Flow Rate of Lavatory taps

82
New cards

4.8 liters/ min. at 417.7 kPa

Maximum Flow Rate of Kitchen faucets

83
New cards

4.8 liters/ min. at 417.7 kPa

Maximum Flow Rate of Handheld bidet sprays

84
New cards

60 psi

Psi for Maximum Flow Rate of Lavatory taps, Kitchen faucets and Handheld bidet sprays.

85
New cards

80 psi

Psi for Maximum Flow Rate of Shower

86
New cards

Rainwater

It is one of the purest sources of water available

87
New cards

75

Minimum storage tanks size (in cu.m) shall be calculated by dividing the building footprint area by ______.

88
New cards

non-potable

Collected rainwater shall be used for _______ purposes such as toilet flushing, irrigation and cooling towers.

89
New cards

Voltaile organic compounds

Paints, coatings, adhesives and sealants used indoors or nonventilated areas shall not contain _______.

90
New cards

urea formaldehyde

Composite wood shall not have _______ content.

91
New cards

1.0 sqm waste storage space per 2,500 sqm TGFA + 50% circulation space

MRF Minimum Daily Storage Space Requirements for Residential Dwelling: Condominium

92
New cards

1.0 sqm waste storage space per 2,500 sqm TGFA + 50% circulation space

MRF Minimum Daily Storage Space Requirements for Hotel / Resort

93
New cards

1.0 sqm waste storage space per 300 sqm TGFA + 50% circulation space

MRF Minimum Daily Storage Space Requirements for Educational: School

94
New cards

1.0 sqm waste storage space per 1,250 sqm TGFA + 50% circulation space

MRF Minimum Daily Storage Space Requirements for Institutional: Hospital

95
New cards

1.0 sqm waste storage space per 1,400 sqm TGFA + 50% circulation space

MRF Minimum Daily Storage Space Requirements for Business: Office

96
New cards

1.0 sqm waste storage space per 400 sqm TGFA + 50% circulation space

MRF Minimum Daily Storage Space Requirements for Mercantile: Mall

97
New cards

Environmental Tobacco Smoke

It is one of the leading causes of respiratory illnesses in building occupants.

98
New cards

RA 9514

If smoking is banned within the building and property premises, "NO SMOKING" signs in compliance with the ________.

99
New cards

10 meters

If smoking is only allowed outdoors, designated smoking areas shall be naturally ventilated, outside of the building shell and away from building entrances, windows and outside supply air (OSA) intakes by at least ______ meters.

100
New cards

15, 3

This GB Code shall take effect _____ days after its publication once a week for _____ consecutive weeks in a newspaper of general circulation.