Which cable type suffers from electromagnetic interference (EMI)?
unshielded twisted pair (UTP)
2
New cards
Which first-generation network topology provided fault tolerance?
star
3
New cards
Which type of cable is described as a central conductor wire that is surrounded by insulating materials and placed inside a braided metal shield?
coaxial
4
New cards
What type of fiber-optic cable uses lasers to send signals?
single-mode fiber (SMF)
5
New cards
What is the meaning of the term "capacitance"?
how long it takes a wire to get a full charge
6
New cards
A manufacturer selling boxed reels of unshielded twisted pair (UTP) cabling will clearly mark the cable's category rating on the connectors at the end of the cable. (T/F)
False
7
New cards
Which term describes a practical application of a topology and other critical technologies that provides a method to get data from one computer to another on a network?
network technology
8
New cards
The most common type of cabling used in networks today consists of fiber-optic cables. (T/F)
False
9
New cards
Fiber-optic cable is attractive for use in high electromagnetic interference (EMI) areas. (T/F)
True
10
New cards
Multimode fiber cables transmit __________ wavelengths.
850-nm
11
New cards
The two types of meshed topologies are partially meshed and wholly meshed. (T/F)
False
12
New cards
Because most networks can run at speeds of up to 1000 Mbps, most new cabling installations use which category of cabling?
Cat 6
13
New cards
Which connector is currently used in wired networks?
8P8C (8 position 8 contact)
14
New cards
UTP category ratings are based on what criteria?
the highest frequency the cable can handle
15
New cards
Which term refers to a relative measure of the resistance (or more precisely, characteristic impedance) on a cable?
Ohm rating
16
New cards
Plenum cable provides less protection than riser-rated cable. (T/F)
False
17
New cards
Which category rating uses a bandwidth of 250 MHz to accommodate 10000 Mbps?
Cat 6
18
New cards
What distance can a signal travel on a fiber-optic cable?
tens of kilometers
19
New cards
Almost all network technologies that use fiber-optic cable require pairs of fibers. (T/F)
True
20
New cards
Which IEEE subcommittee sets the standards for Wireless LAN networks?
802\.11
21
New cards
What statement describes the advantage of fault tolerance?
If one cable breaks, all of the other computers can still communicate.
22
New cards
Which cable creates much less smoke and fumes when burned, but costs about three to five times as much as PVC-rated cable?
plenum-rated
23
New cards
What is the space between the acoustical tile ceiling in an office building and the actual concrete ceiling above called?
plenum
24
New cards
What is the primary use of coaxial cable in networking today?
connecting a cable modem to an Internet service provider (ISP)
25
New cards
In response to the demand for two-pair cabling, manufacturers often connect two fibers together to create __________ fiber-optic cabling.
duplex
26
New cards
What is the minimum category rating of UTP cabling you would need for a network that runs at 1000 Mbps?
Cat 5e
27
New cards
In a partially meshed topology network, at least two machines have redundant connections. (T/F)
True
28
New cards
Which fire cable rating has no significant fire protection?
cable with a polyvinyl chloride (PVC) rating
29
New cards
Which type of cable is uses a two-number designator consisting of core and cladding measurements?
fiber-optic
30
New cards
Most new cabling installations use Category 3 (Cat 3) unshielded twisted pair (UTP) cables. (T/F)
False
31
New cards
Which IEEE committee defines frames, speeds, distances, and types of cabling to use in a network environment?
IEEE 802
32
New cards
A type of fire rating known as __________ designates the proper cabling to use for vertical runs between floors of a building.
riser
33
New cards
Unshielded twisted pair (UTP) category (Cat) ratings are officially rated in megahertz (MHz), indicating the highest frequency the cable can handle. (T/F)
True
34
New cards
What is the only important measure of coax cabling?
Ohm rating
35
New cards
A __________ cable that uses LEDs is known as multimode fiber (MMF).
fiber-optic