Looks like no one added any tags here yet for you.
Important note
No spraying chemicals inside the pec
Required cleaning supplies
sterile tb1, swfi, sterile 70% isopropyl alcohol wipe or bottle, sterile gamma absorbent wipe, protective eyewear, cleaning tool(mop)
Where should open bottles remain until empty?
They must remain in the buffer room
Before cleaning what should you do?
You should remove any visible particles, debris, or residue with an appropriate solution with a gamma wipe
Before using the cleaning tool in the pec what should occur?
It must be cleaned with sterile 70% ipa wipes
what should be cleaned first
the protective grill over the hepa filter should be cleaned first, from side to side and back to front
what is cleaned after the protective grill?
the rest of the pec is cleaned, in the following order: back wall, side walls, lift and wipe bar, brackets and hook, interior glass, top of the work surface and front and back air intake grate
what cleaning products is used first?
tb-1
how long does tb-1 need to remain wet?
1 minute
what is the optional step?
rinsing the tb-1 off with sterile water
what cleaning product do you use on the second clean?
sterile 70% ipa wipes or bottle
what wet time does sterile 70% ipa require?
1 minute
how long does the pec need to run before using?
3 minutes
what else in the buffer room needs to be cleaned?
high-touch surfaces
what should happen after cleaning?
gloves should be removed and antiseptic hand cleansing should occur before gloving