New cards

where are construction specifications and drawings submitted to in order to get a permit

the engineering division of the NC department of insurance

2
New cards

if you’re in a section 403 high rise when do building plans need to be approved

all building drawings must be approved

3
New cards

if you’re building a covered mall building when do building plans need to be approved

all building drawings must be approved

4
New cards

in a city/county owned building when do building plans need to be approved

when the building is 20,000 sq/ft or more

5
New cards

In a group A (assembly) building when do building plans need to be approved

when occupant load is over 1,000

6
New cards

in a group E (education) building when do plans need to be approved

when its over 2 stories or over 20,000 sq/ft per story

7
New cards

in a group H (hazard) building when do plans need to be approved

when occupant load is over 100

8
New cards

in a group I (institutional) building when do plans need to be approved

in buildings over 3 stories or over 10,000 sq/ft per story

9
New cards

in a group r (residential) building when do plans need to be approved

if there’s over 4 stories or more than 100 units per building

10
New cards

how are approvals issued from the state

issued in writing or by stamp

11
New cards

what inspections are required in NC

footing, under slab (if applicable), foundation, rough-in, building framing, insulation, fire protection, final inspection

12
New cards

rough in inspection

shall be made when all building framing and parts of the electrical, plumbing, fire protection or heating ventilation or cooling system that will be hidden from view have been placed

13
New cards

building framing inspection

made after the roof, wall ceiling and floor framing is complete w/ appropriate blocking, bracing and firestopping in place

14
New cards

insulation inspection

done after permanent roof is attached

15
New cards

how should work be performed with inspections

the next phase of work cannot happen until the inspection is passed unless you obtained approval of the code enforcement official first

16
New cards

whose job is it to request/schedule inspections

the permit holder

17
New cards

appeals to code must be made ____ days from the date of decision of the State Enforcement agency

30

18
New cards

a notice of appeal must be made to the building code council _____ days prior to the Hearing Committee meeting

15

19
New cards

who can stop a work order

county code officials; they can do so under GS 153A-361

20
New cards

a permit expires after ____ after the date of issue if no work has started on it

6 months

21
New cards

If work is discontinued for ____________ the permit immediately expires

12 months

22
New cards

building occupancy loads must be

posted by the owner of the building in each assembly room

23
New cards

any violation of code is a

class 3 misdemeanor