what is the mode 1-4 SIT tech specs
2300-4400 PPM
1750-1950 cubic feet
600-625 PSIG n2
MOVs open and deenergized
how many hours to recover SIT boron? what about the other inop reasons
72 hours to restore from boron, 24 hours for everything else
what is required if the SITs cant be restored
mode 3 in 6 hours and less than 1837 psia in 12 hours
whats assumed with the SITs regarding a LBLOCA
3 sits assumed to inject, one is lost to the break
what are the SIT requirements when shutdown (mode 3-4)
MOV open greater than 430 psia
power removed greater than 1500 PSIA
2300-4400 PPM
260-625 PSIG N2 pressure
1361-2000 cubic feet (if 3 operable)
908-2000 cubic feet (if 4 operable)
what is required if 2 or more SITs inoperable
enter LCO 3.0.3 immediately
when is boron required to be checked when draining a sit to maintain level?
boron required to be checked within 6 hours due to potential of RCS in leakage
when are two ECCS trains required to be operable
modes 1-3 PZR greater than 1837 PSIA or Tc greater than 485 F
during shutdown how many trains of HPSI are required and how long do we have to restore
1 train of HPSI required and needs to be restored in 1 hour or be in mode 5 in 24 hrs
what are the tech spec requirements for the RWT?
60-120F
4000-4400 ppm
81.2-84.3% level based on Tave
what is the design flow of a HPSI?
75% of minimum design flow of one HPSI pump is capable of meeting or exceeding the decay heat boil off rate
what is the purpose of the minimum level requirements in the RWT
ensures we have NPSH for the SI pumps
ensures SDM maintained during a LOCA
Less volume is required at lower RCS temps due to less RCS contraction from a cooldown
what is the design basis of the max boron PPM concentration
limits boron precipitation in the core following a LCOA
how much TSP is required while operating modes 1-3? how long do we have to restore?
524 cubic feet
restore within 72 hours
what is the purpose of TSP?
raises recirc water PH to 7 and maintains Iodine in solution