Republic Act no 9514
an Act establishing a comprehensive Fire Code of the Philippines, repealing Presidential Decree no. 1185, and for other purposes.
2
New cards
Anesthetics Gas
A medical gas used as anesthetic agents for surgical procedures
that could either be flammable or non-flammable.
3
New cards
cyclopropane and ethylene
Examples of flammable anesthetics
4
New cards
nitrous oxides and
halothane
Examples of nonflammable anesthetic gases
5
New cards
Arena stage
A stage or platform that opens on at least three (3) sides to audience seating. It may be with or without overhead scene handling
facilities.
6
New cards
Automatic Fire Suppression System
An integrated system of underground or overhead piping or both connected to a source of extinguishing agent or medium and
designed in accordance with fire protection engineering standards
which, when actuated by its automatic detecting device, sup-
presses fires within the area protected.
7
New cards
Baffle
A non liquid-tight transverse partition in a cargo tank.
8
New cards
Bale
A large bundle or package of hay or a raw material such as
cotton, tightly bound with string or wire to keep it in shape during
transportation or storage.
9
New cards
2.00 m
Minimum height of doors
10
New cards
710 mm (minimum)
1220 mm (maximum)
Minimum and maximum width of doors
11
New cards
2.30 m

(however, follow the min. 2.40 m of NBCP)
Minimum height for habitable rooms
12
New cards
Min. of 100-180mm
Dimensions of stair risers
13
New cards
Min. of 280mm
Dimensions of stair run/tread
14
New cards
760-865mm from nosing
Handrail Height
15
New cards
1.12 m
Dimension of landings in the direction of travel
16
New cards
1:12
Maximum slope of ramps
17
New cards
1:48
Maximum cross slope of ramps
18
New cards
1.12 m
Minimum width of ramps
19
New cards
760 mm vertical distance
Distance between landings
20
New cards
at LEAST 2 exits
Number of exits for occupant load 0-500
21
New cards
at LEAST 3 exits
Number of exits for occupant load 501-900
22
New cards
at LEAST 4 exits
Number of exits for occupant load 1000 above
23
New cards
Max. of 46 m
Distance to exits w/o sprinkler system
24
New cards
Max. of 61 m
Distance to exits w/ sprinkler system
25
New cards
Cryogenic Fluids
Fluids produced or stored at very low temperatures and that have
normal boiling point below negative fifty five degrees Celsius (-
55°C).
26
New cards
Class I-A Liquids
include those flammable liquids having flash points below twenty
two and eight tenths degrees Celsius (22.8°C), and having a
boiling point below thirty seven and eight tenths degrees Celsius
(37.8°C).
27
New cards
Class I-B Liquids
include those flammable liquids having flash points below twenty
two and eight tenths degrees Celsius (22.8°C), and having a
boiling point at or above thirty seven and eight tenths degrees
Celsius (37.8°C).
28
New cards
Class I-C Liquids
include those liquids having flash points at or above twenty two
and eight tenths degrees Celsius (22.8°C), and below thirty seven
and eight tenths degrees Celsius (37.8°C).
29
New cards
Fumigants
Any substance which, by itself or in combination with any other
substance, emits or liberates a gas, fume or vapor used for the
destruction or control of insects, fungi, vermin, germs, rats, or
other pests, and shall be distinguished from insecticides and
disinfectants which are essentially effective in the solid or liquid
phases.
30
New cards
Refrigerating System
An assembly of four (4) major components, namely the compres-
sor, condenser, expansion valve, the evaporator, through which
a very low boiling point substance (refrigerant) flow in cycle, and
absorbs heat from the immediate surroundings, thereby produc-
ing the cooling effect (also known as the refrigerating effect).
31
New cards
Means of Egress
A continuous and unobstructed route of exit from any point in a
building to a public way.
32
New cards
Class A
Class of fire involving ordinary combustible materials, such as
wood, papers, cloth,
rubber, and plastics.
33
New cards
Class D
Class of fire involving combustible metals, such as magnesium,
sodium, potassium, and
other similar materials.
34
New cards
14
Maximum number of seats in a row in between aisles.
35
New cards
0.83 mtr.
Minimum spacing of rows of seats from back to back for a public
assembly building.
36
New cards
0.915 m
Minimum width of means of egress
37
New cards
Floor Area Assigned / Occupant Load Factor
Formula for occupant load computation
38
New cards
1 hour fire resistance rating
Protective enclosure of exits shall have at least \______ fire resistance rating when connected to 3 storeys or less.
39
New cards
2 hour fire resistance rating
Protective enclosure of exits shall have at least \______ fire resistance rating when connected to 4 storeys or more.
40
New cards
Assembly
Under what classification of occupancy does MUSEUMS fall?
41
New cards
Business
Under what classification of occupancy does town HALLS fall?
42
New cards
Fire Brigade
A collective term that is used to refer to a group of firefighters, primarily performing fire suppression activities in areas such as, but not limited to, community/barangay, company, and other government and nongovernment establishments.
43
New cards
Flame Retardant
Any compound or mixture which when applied properly improves
the resistivity or fire resistance quality of fabrics and other mate-
rials.
44
New cards
Flame Spread Rating
The time in which flame will spread over the surface of a burning
material.
45
New cards
Flash Point of a Liquid
The lowest temperature a liquid at which sufficient vapor is given
off to form an ignitable mixture with air, near the surface of the
liquid or within the vessel used, as determined by appropriate
laboratory test,
46
New cards
Panic Hardware
A mechanical device consisting of linkages and horizontal bars
across a door, which when pushed from the inside will cause the
door to open and facilitates exit from the building, structure or
facility.
47
New cards
Sump Pit
The lowest part of a mine, vault, tank or a hole in the ground used
to collect water, waste water and sludge for purposes of draining
through a submersible pump.
48
New cards
0.28 sqm
Unit area per person for waiting areas or standing rooms.
49
New cards
91 cms.
Minimum width of an aisle serving an occupant of 60.
50
New cards
2.00 mts
Minimum headroom created by any projection from the ceiling.
51
New cards
56 cms.
Minimum clear width of turnstiles.
52
New cards
112 cms
Minimum dimension of landings in direction of travel for class A &
B stairs.
53
New cards
3
Minimum number of risers in any one (1) flight of stairs.
54
New cards
76 cms.
Minimum height of a handrail above the upper surface of the tread.
55
New cards
38 mm
Minimum clearance of a handrail from any wall.
56
New cards
91 cms
Minimum height of a guard rail.
57
New cards
106 cms
Maximum height of a guard rail.
58
New cards
7.50 mt
Minimum inner radius of a monumental stair.
59
New cards
112 cms
Minimum width of any balcony or bridge.
60
New cards
112 cms.
Minimum width of a class A ramp.
61
New cards
20.3 cms
Maximum rise of any floor from the balcony floor to which an
access door leads.
62
New cards
55.9 cms (same size for landings)
Minimum width of a fire escape stair for existing stairs.
63
New cards
15.25 cms.
Minimum tread for a fire escape stair for SMALL buildings.
64
New cards
30.5 cms.
Maximum rise of fire escape stair for a SMALL building.
65
New cards
22.9 cms.
Maximum rise of fire escape stair for existing stairs.
66
New cards
2.13 mts
Minimum headroom clearance for a fire escape stair for existing
stairs.
67
New cards
1.98 mts.
Minimum headroom clearance for a fire escape stair for SMALL
buildings.
68
New cards
50-300
Maximum occupant load for a class C public assembly.
69
New cards
2
Minimum number of exit for an INSTITUTIONAL type of structure.
70
New cards
30 mts
Maximum travel distance between ROOM door intended as exit
access and EXIT WITH SPRINKLER system for INSTITUTIONAL use.
71
New cards
30 mts
Maximum travel distance from the DOOR of any room to EXIT for
HOTELS WITH SPRINKLER
72
New cards
2.5 cms.
Minimum increase in width for an aisle per linear meter.
73
New cards
91 cms.
Minimum width of an aisle serving an occupant of 60 or more serving one side for a public assembly building.
74
New cards
1.00 mtr.
Minimum width of an aisle serving an occupant of 60 or more serving two sides for a public assembly building.
75
New cards
76 cms.
Minimum width of an aisle serving an occupant of below 60 for a
public assembly building.
76
New cards
1.80 mts
Minimum width of an aisle for an EDUCATIONAL use building.
77
New cards
2.44 mts.
Minimum width of an aisle for HOSPOTALS or nursing homes
78
New cards
112 cms.
Minimum width of an aisle for BUSINESS and INDUSTRIAL use structure.
79
New cards
Picking rooms
Rooms where baled, bundled or piled materials segregated into
desired sizes or groups.
80
New cards
Plenum
An air compartment or chamber to which 1 or more ducts are
connected and which form
part of an air distribution system
81
New cards
37.8 degrees Celsius / 100 Fahrenheit
Temperature rating at flash point.
82
New cards
4 hrs.
MIN. fire resistance rating for a FIREWALL.
83
New cards
Flash Point
The minimum temperature at which any material gives off vapor in sufficient
concentration to form an ignitable mixture with air.
84
New cards
4.50 mts
Minimum width of any driveway in and around a lumber yard /
piles.
85
New cards
3.70 mts.
Maximum width of sumps for the retention of oil and petroleum
products.
86
New cards
15.00 mts.
Minimum travel distance from any individual room subject to occupancy by not more 6 persons.
87
New cards
23.00 mts.
Maximum distance of travel from the high hazard area to an exit.
88
New cards
3.00 mts.
Minimum distance of an incinerator from any structure used other
than a single family
dwelling
89
New cards
9 cms.
Maximum reduction in width of a stair by a handrail.
90
New cards
20.5 cms.
Maximum CHANGE IN ELEVATION between the INTERIOR of a door to the
OUTSIDE of it other than
a balcony
91
New cards
7 kgs.
Maximum force in kilograms required for a panic hardware.
92
New cards
76 cm - 112 cm (min./max.)
Height required for a panic hardware installation.
93
New cards
20
Maximum number of occupant for a subdivided room or space by
a FOLDING partition.
94
New cards
91 cms.
Minimum stair width for a class B stair serving an occupant load
of less than 50.
95
New cards
25 mm
Length of a NOSING or effective projection over the level immediately below it for tread BELOW 25 cms in dimension.
96
New cards
86.5 cm
Maximum height of a handrail.
97
New cards
30.5 meters
Classified as MERCANTILE occupancies, the travel distance from
exits shall be.
98
New cards
1 (1.5 mts WIDE)
Minimum number of aisles for Class 'A' stores.
99
New cards
3.66 mts.
Minimum CLEAR WIDTH of an EXIT access through a covered mall.
100
New cards
15 mts
Minimum height of buildings requiring automatic sprinkler protection.