PLUMBING
IT REFERS TO THE SYSTEM OF PIPES, FITTINGS, AND FIXTURES INSTALLED IN BUILDING FOR THE DISTRIBUTION OF POTABLE WATER FOR DRINKING, HEATING, AND WASHING, AND REMOVAL OF WATERBORNE WASTES.
TO SUPPLY WATER TO DIFFERENT PARTS OF THE BUILDING & TO REMOVE AND DISCHARGE HUMAN WASTES AND OTHER SUBSTANCES
WHAT ARE THE OBJECTIVES OF PLUMBING?
SUFFICIENT AMOUNT OF WATER
CONDITIONS OF EFFECTIVE WATER SUPPLY IN BUILDING;
TO PROVIDE _____________ TO SUPPLY EACH FIXTURE.
PREVENT BACKFLOW OF USED WATER
CONDITIONS OF EFFECTIVE WATER SUPPLY IN BUILDING;
TO _____________ INTO THE WATER SUPPLY SYSTEM.
FAST REMOVAL OF WASTE
_________________ WITH MINIMUM PROBABILITY OF LEAKAGE AND STOPPAGE OF DRAINS.
PREVENT ENTRY OF HOUSE VERMIN AND OBNOXIOUS GASES
TO _____________ INTO THE HOUSE FROM THE PIPPING SYSTEM.
PURE AND WHOLESOME WATER
ALL PREMISES INTENDED FOR HUMAN HABITATION, OCCUPANCY OR USE SHALL BE PROVIDED WITH SUPPLY OF _____________, NEITHER CONNECTED WITH UNSAFE WATER SUPPLIES NOR SUBJECT TO HAZARDS OF BACKFLOW OR SIPHONAGE.
SUFFICIENT VOLUME AND AT PRESSURE ADEQUATE
PLUMBING FIXTURES, DEVICES AND APPURTENANCES SHALL BE SUPPLIED WITH WATER IN _______________________ TO ENABE THEM TO FUNCTION SATISFACTORILY AND WITHOUT UNDUE NOISE UNDER ALL NORMAL CONDITIONS OF USE.
MINIMUM QUANTITY OF WATER
PLUMBING SHALL BE DESIGNED AND ADJUSTED TO USE THE _______________ CONSISTENT WITH PROPER PERFORMANCE AND CLEANING.
DANGERS FROM EXPLOSION
DEVICES FOR HEATING AND STORING WATER SHALL BE SO DESIGNED AND INSTALLED AS TO PREVENT __________________ THROUGH OVERHEATING.
PUBLIC SEWER
EVERY BUILDING HAVING PLUMBING FIXTURES INSTALLED AND INTENDED FOR HUMAN HABITATION, OCCUPANCY OR USE ON PREMISES ABUTTING ON A STREET, ALLEY OR EASEMENT WHERE THERE IS A _____________, SHALL BE CONNECTED INTO THE SEWER SYSTEM.
ONE WATER CLOSET & ONE KIT. TYPE SINK
EACH FAMILY DWELLING UNIT ON PREMISES ABUTTING ON A SEWER OR WITH A PRIVATE SEWAGE DISPOSAL SYSTEM SHALL HAVE AT LEAST ________________.
SMOOTH, NON-ABSORBENT MATERIALS
PLUMBING FIXTURES SHALL BE MADE OF _____________________, FREE FROM CONCEALED FOULING SURFACES AND SHALL BE LOCATED IN VENTILATED ENCLOSURES.
ADEQUATE CLEANOUTS
THE DRAINAGE SYSTEM SHALL BE DESIGNED, CONSTRUCTED AND MANTAINED TO SAFEGUARD AGAINST FOULNG, DEPOSIT OF SOLIDS, CLOGGING AND WITH ________________ SO ARRANGED THAT THE PIPELINES MAY READILY CLEANED
DURABLE & APPROVED MATERIALS
ALL PIPING OF PLUMBING SYSTEMS SHALL BE OF ___________________, FREE FROM DEFECTIVE WORKMANSHIP, DESIGNED AND CONSTRUCTED BY REGISTERED MASTER PLUMBER TO EMSURE SATISFACTORY SERVICE
WATER-SEALED TRAP
EACH FIXTURE DIRECTLY CONNECTED TO THE DRAINAGE SYSTEM SHALL BE EQUIPPED WITH A ______________.
ADEQUATE CIRCULATION OF AIR
THE DRAINAGE PIPING SYSTEM SHALL BE DESIGNED TO PROVIDE _________________ FREE FROM SIPHONAGE, ASPIRATION OR FORCING OF TRAP SEALS UNDER ORDINARY USE.
VENT TERMINALS
__________________ SHALL BE EXTENDED TO THE OUTER AIR AND INSTALLED TO PREEMPT CLOGGING AND RETURN OF FOUL AIR TO THE BUILDING.
EFFECTIVELY DISCLOSE ALL LEAKS AND DEFECTS
PLUMBING SYSTEMS SHALL BE SUBJECTED TO SUCH TESTS TO ______________ IN THE WORKMANSHIP.
PRODUCE EXPLOSIVE MIXTURES
NO SUBSTANCE WHICH WILL CLOG THE PIPES, ______________, DESTROY THE PIPES OT THEIR JOINTS OR INTERFERE UNDULY WITH THE SEWAGE DISPOSAL PROCESS SHALL BE ALLOWED TO ENTER THE BUILDING DRAINAGE SYSTEM.
BACKFLOW OF SEWAGE
PROPER PROTECTION SHALL BE PROVIDED CONTAMINATION OF FOOD, WATER, STERILE GOODS AND SIMILAR MATERIALS BY _____________.
LIGHTED OR VENTILATED
NO WATER CLOSET SHALL BE LOCATED IN A ROOM OR COMPARTMENT WHICH IS NOT PROPERLY _________________.
SEWAGE TREATMENT AND DISPOSAL
IF WATER CLOSETS OR OTHER PLUMBING FIXTURE ARE INSTALLED IN BUILDINGS WHERE THERE IS NO SEWER WITH A REASONABLE DISTANCE, SUITABLE PROVISION SHALL BE MADE FOR DISPOSING OF THE BUILDING SEWAGE BY SOME ACCEPTANCE METHOD OF ________________, SUCH AS SEPTIC TANK
PREVENT ITS OVERFLOW
WHERE A PLUMBING DRAINAGE SYSTEM MAY BE SUBJECT TO BACKFLOW OF SEWAGE, SUITABLE PROVISION SHALL BE MADE TO ______________________ IN THE BUILDING.
SERVICEABLE CONDITION
PLUMBING SYSTEMS SHALL BE MAINTAINED IN _______________ BY REGISTERED MASTER PLUMBERS
PROPERLY SPACED
ALL PLUMBING FIXTURES SHALL BE INSTALLED _______________, TO BE ACCESSIBLE FOR THEIR INTENDED USE.
PRESERVATION OF THE STRENGTH
PLUMBING SHALL BE INSTALLED BY REGISTERED MASTER PLUMBERS WITH DUE REGARD TO THE ________________ OF STRUCTURAL MEMBERS AND THE PREVENTION OF DAMAGE TO WALLS AND OTHER SURFACES THROUGH FIXTURE USAGE.
RENDERED INNOCUOUS
SEWAGE OR OTHER WASTE FROM A PLUMBING SYSTEM WHICG MAY BE DELETERIOUS T SURFACE OR SUB SURFACE WATER SHALL NOT BE DISCHARGE INTO THE GROUND OR INTO ANY WATERWAY, UNLESS FIRST _____________ THROUGH SUBJECTION TO SOME ACCEPTABLE FORM OF TREATMENT.
17TH CENTURY
THE BIRTH OF PLUMBING PROFESSION
WALLED CITY
KNOWN AS INTRAMUROS WAS ESTABLISHED BY THE SPANIARDS AS A MODEL COMMUNITY
ILUSTRADOS
THE RECOGNIZED PLUMBERS THEN WERE CALLED UPON BY THE ________________, OR THE ELITE GROUP TO ACT AS CONSULTANTS OF PLUMBER JOURNEYMEN ON MATTERS PERTAINING TO PLUMBING INSTALLATION IN VILLAS AND MANSION
PUEBLOS
IN 18TH AND 19TH CENTURY, FILIPINO PLUMBERS WERE ASSIGNED THE TASK OF MAINTANING, REPAIRING AND REMODELING SYSTEMS IN ALL ___________ OR TOWNS INCLUDING CHURCHES, CONVENTS AND GOVERNMENT BUILDINGS.
EL DEPOSITO
THE CARVERNOUS, ONE OF THE OLDEST UNDERGROUND RESERVOIRS IN THE WORLD ADN THE COUNTRY’S LARGEST SPANISH ERA ARTIFACT, WAS BUILT AS PART OF THE CARRIEDO WATERWORKS WAS BUILT FROM 1878 TO 1882
GOVERNOR GENERAL F.B. HARRISON
HE ISSUED A LETTER OF INSTRUCTION ON PROPER DISPOSAL IN ALL MUNICIPALITIES
20TH CENTURY
HEALTH AND HYGIENCE BECAME PRIORITY WHEN EPIDEMICS INCLUSDING CHOLERA, LEPROSY, SCHISTOSOMIASIS AND OTHER CONTAGIOUS DISEASE ENGULFED THE PHILIPPINES
SANITARY ENGINEER
APPLICATION OF ENGINEERING METHODS TO IMPROVE SANITATION OF HUMAN COMMUNITIES
MASTER PLUMBER
A LICENSE PERSON SPECIALIZE IN WATER, SEWAGE ADN DRAINAGE SYSTEMS USUALLY IN RESIDENTIAL AND COMMERCIAL ESTABLISHMENT
PLUMBER
A TITLE GVEN TO A PERSON WHO IS SKILLED THAT INSTALLS OR REPAIRS PIPING SYSTEM ALOSO KNOWN AS JOURNEYMAN
1902
YEAR OF WHEN PLUMBING TRADE WAS DULY RECOGNIZED BY THE GOVERNMENT
JOHN F. HASS
THE MASTER PLUMBER WHO BECAME THE FIRST CHIEF OF THE DIVISION OF PLUMBING CONSTRUCTION AND INSPECTION.
BUILDING CODE FOR THE CITY OF MANILA
THROUGH THE INITIATIVE OF THE FILIPINO MASTER PLUMBERS, A PLUMBING CODE BASED ON THE PLUMBING CODE OF THE UNITED STATES WAS INCORPORATED
1935
YEAR WHERE (NAMPAP) WAS FOUNDED REGISTERED WITH THE SECURITIES AND EXCHANGE COMMISION?
NATIONAL MASTER PLUMBING ASSOCIATION OF THE PHILIPPINES
WHAT IS THE MEANING OF THE ACRONYM OF NAMPAP?
DEPARTMENT OF PUBLIC SERVICES
MANILA CITY ORDINANCE 2411, OTHERWISE KNOWN AS “THE PLUMBING CODE FOR THE CITY OF MANILA” WAS ENACTED IN CONSUKTATION WITH NAMPAP. THE PRACTICE OF PLUMBING WAS EVENTUALLY PLACED UNDER THE ________________.
DECEMBER 21, 1999
DATE WHERE PRESIDENT JOSEPH EJERCITO ESTRADA APPROVED THE PURSUANT TO SECTION 4 OF R.A. 1378 KNOWN AS PLUMBING LAW
1972
REPUBLIC ACT NO. 6541 OTHERWISE KNOWN AS BUILDING CODE OF THE PHILIPPINES WAS PASSED WITH THE NATIONAL PLUMBING CODE OF 1959 AS REFERRAL IN FULL TEXT
JAIME M. CABASE
NAMPAP PRESIDENT WHO IS SPEARHEADED THE UPDATING REVISED NATIONAL PLUMBING CODE
OCTOBER 1999
DATE AS TO WHEN NAMPAP SUBMITTED THE DRAFT CODE TO THE BOARD MASTER PLUMBERS (BOMP) CHAIRED BY ENGR. FORTUNATO H. AMOSCO
HERMOGENES POBRE
THE PRC CHAIRMAN WHO ADOPTED THE REVISED PLUMBING CODE OF 1999
HOUSE BILL NO. 962
THE THIRD CONGRESS OF THE REPUBLIC OF THE PHILIPPINES APPROVED THE _________________, WHEREIN THIS BECAME REPUBLIC ACT NO. 1378.
PLUMBING LAW OF THE PHILIPPINES
JUNE 18, 1955, R.A. 1378, OTHERWISE KNOWN AS THE __________________ BY PRESIDENT RAMON MAGSAYSAY
NOVEMBER 28, 1967
FIRST AMENDMENT TO THE NATIONAL PLUMBING CODE WAS APPROVED, WHICH EFFECTED THE INCLUSION PF ABESTOS-CEMENT PIPE AS AN APPROVED PLUMBING MATERIAL
NAWASA
NAMPAP ALSO ASSISTED IN THE PASSAGE OF THE LAW CREATING THE ______________________.
JANUARY 28, 1959
DATE WHEN NATIONAL PLUMBING CODE OF THE PHILIPPINES PREPARED BY NAMPAP WAS PROMULGATED AND APPROVED BY MALACAÑANG
FEATI UNIVERSITY
IN 1966-1969, THE BOARD OF EXAMINERS FOR MASTER PLUMBERS AND THE NAMPAP PREPARED A CURRICULUM FOR PLUMBING ENGINEERING THAT WAS APPROVED THE DEPARTMENT OF EDUCATION AND WAS FIRST INTRODUCED AT THE _______________.