Gray water installations exceeding a maximum discharge capacity of 250 gallons per day
shall be designed by a __________________.
a. licensed plumbing designer
b. licensed plumber
c. licensed architect
d. registered design professional
D
The total estimated gray water flow for each occupant in a single family home shall be ____________________ gpm.
a. 15
b. 25
c. 35
d. 40
D
All valves, including the three-way valve, shall be ______________.
a. accessible
b. metal
c. non corrosive
d. plastic
A
The reclaimed water system shall not be connected to a _____________.
a. building sewer
b. house sewer
c. subsurface drain
d. potable water system
D
For gray water surge tanks of 75 gallons or less, the distance or clearance to a building or
structure may be reduced to ______ ft.
a. 0
b. 5
c. 10
d. 15
A
All valves shall be equipped with a locking feature except for ____________.
a. fixture supply control valves
b. fullway valves
c. gate valves
d. main valves
A
The maximum downstream pressure from a pump serving a gray water irrigation field shall
not exceed ____________ psi.
a. 10
b. 15
c. 20
d. 30
C
Subsurface irrigation fields and mulch basins shall be sized as per _______________.
a. Table 703.2
b. Table 1502.10
c. the inlet size
d. Table 1502.11
B
Gray water supply piping, including drip feeders, shall be not be less than ____________ inches below finished grade and covered with mulch.
a. 2
b. 6
c. 10
d. 12
A
The distance between a septic tank and a gray water disposal field shall be _______.
a. 5
b. 10
c. 12
d. 20
A
Where irrigation and disposal fields are installed in sloping ground, the minimum horizontal
separation between the distribution system and ground surface shall be _________ feet
a. 5
b. 15
c. 30
d. 50
B
Gray water systems shall be designed to distribute the total amount of estimated gray water on a(n) __________________.
a. twice daily basis
b. daily basis
c. hourly basis
d. yearly basis
B
Reclaimed water pipes shall be permitted to run in the same trench as potable water pipes with a ______________ inch minimum vertical and horizontal separation where both pipe materials are approved for use within a building.
a. 6
b. 12
c. 18
d. 24
B
On-site treated nonpotable water piping shall comply with ____________.
a. Section 610.0
b. Table 1502.4
c. Table 1502.11
d. Section 1601.12
A
On-site treated water systems shall have a colored background and marking information in
accordance with Section ____________ of this code.
a. 601.3
b. 1502.9.1
c. 1503.7
d. 1602.10
A
Upon discovery of a cross-connection, the potable water system shall be chlorinated with ___________ parts-per-million.
a. 50
b. 75
c. 100
d. 110
A
In calculating for gray water systems, the first bedroom is equal to __________ occupants.
a. 1
b. 2
c. 3
d. 4
B
The gray water discharge amount for a laundry is _____________ gallons per day/occupant.
a. 5
b. 10
c. 15
d. 20
C
Surge tanks placed above ground shall be placed _________________.
a. on a 1" concrete slab
b. on a 2" concrete slab
c. on a 3" concrete slab
d. on flat ground
C
A filter permitting the passage of particulates no larger than__________ microns shall be provided for on-site treated nonpotable water supplied to water closets, urinals, trap primers, and drip irrigation system.
a. 25
b. 50
c. 75
d. 100
D
3-inch piping conveying on-site treated non-potable water shall have lettering with a
minimum size of __________ inch(es).
a. 1/2
b. 3/4
c. 1
d. 1-1/4
D
Each room containing alternate water source non-potable water and equipment shall have
signage with visible lettering _________ inch.
a. 1/2
b. 3/4
c. 1
d. 1-1/4
C
The maximum absorption capacity for sandy clay is _______ gallons per feet of irrigation/leaching area for a 24-hour period.
a. 1.1
b. 1.7
c. 2.5
d. 4.0
B
The discharge from a ____________ is not used to calculate gray water discharge.
a. bath or shower
b. kitchen
c. lavatory
d. laundry
B
No excavation for an irrigation field, disposal field, or mulch basin shall extend within _____________ feet vertical of the highest known seasonal groundwater level, nor to a depth where gray water contaminates the groundwater or surface water.
a. 2
b. 3
c. 5
d. 6
B