RAID Levels

0.0(0)
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
Card Sorting

1/25

encourage image

There's no tags or description

Looks like no tags are added yet.

Study Analytics
Name
Mastery
Learn
Test
Matching
Spaced

No study sessions yet.

26 Terms

1
New cards

RAID 1

What is another name for hard disk mirroring

2
New cards

Minimum amount of disks for RAID 5?

3

3
New cards

RAID 5

Disk striping and parity and allows for failure of one drive

4
New cards

RAID 0

Performance over redundancy

5
New cards

RAID 0

Sum of all the disks used

6
New cards

RAID 0

Has no redundancy

7
New cards

RAID 1

Data can be Recovered if a drive fails because of mirroring (in this case only because of a perfect mirror)

8
New cards

RAID 1

Half amount of space and slow write performance?

9
New cards

RAID 1

Improves read speed as the data mirrored between two drives

10
New cards

RAID 4

________ stripes the data across multiple disks just like RAID 0. In addition to that, it also stores parity information of all the disks in a separate dedicated disk to achieve redundancy

11
New cards

RAID 4

If the dedicated parity disk fails, data redundancy is lost

12
New cards

RAID 4

The write performance becomes slow because all the parity information is written on a single disk which is a bottleneck

13
New cards

Minmum amount of drives for RAID 0

2

14
New cards

Minimum amount of drives for RAID 1

2

15
New cards

3

RAID 4 uses how many disks?

16
New cards

Riad 5 needs a minimum of _____ disks?

3

17
New cards

RAID 5

Can lose any disk out of three and restore data (one amount of disk space is lost because all parity data is split between the drives)

18
New cards

One disks worth of space is used up to store redundancy information. It is split across all of the drives used.

RAID 5

19
New cards

RAID 6

Can handle up to 2 failed drives

20
New cards

A minmum of 4 disks is needed to use this array

RAID 6

21
New cards

RAID 6

Each disk has two parity blocks?

22
New cards

RAID 10 (1+0) needs a minimum of _____ drives?

4

23
New cards

RAID 10

Combines the striping and mirroring of two other arrays.

24
New cards

RAID 10

Performance of RAID 0 and redundancy of RAID 1

25
New cards

You can safely lose one drive from each mirrored pair without data loss, but if two drives fail within the same mirrored pair, data will be lost.

RAID 10

26
New cards

Each disk has two parity blocks which are stored on different disks across the array

RAID 6