New cards

When volts are higher than 32 volts for either bus and the HIGH VOLTS annunciation appears

Alternator Control Unit Failure

Use Abnormal Checklists

2
New cards

Volts are lower than 24.5, LOW VOLTS Annunciator

Alternator Failure

Use Abnormal Checklists

3
New cards

What is the Garmin Failure Recovery?

  1. Reset Circuit Breaker

  2. Check the system status page

  3. Maintain VMC or exit IMC

4
New cards

Pitot tube is blocked, drain hole is open

ASI indicates 0

5
New cards

Pitot tube and drain hole clogged

ASI works as an Altimeter

6
New cards

Static Port Blockage

  1. Altimeter freezes

  1. Airspeed works as an inverted Altimeter, only indicating correctly at frozen altitude

  2. VSI indicates 0