Air Gap
Unobstructed vertical distance through free atmosphere between the lowest water supply opening and the flood level rim.
Backflow
Flow into potable water pipes from a non-intended source.
Back Siphonage
Backflow due to negative pressure causing contaminated water to enter supply.
Battery of Fixtures
Two or more similar fixtures discharging into a common horizontal waste pipe.
Bib
Synonymous with faucet (preferred term).
Blind Flange
Closes pipe end with no opening.
Blow-Off
Controlled outlet used to discharge water.
Branch
Any piping other than main riser or stack.
Branch Interval
Storey height of stack, minimum 2.40 m, where horizontal branches connect.
Branch Vent
Vent connecting individual vents to a vent stack.
Calking
Plugging openings using oakum, lead, or similar materials.
Circuit Vent
Branch vent serving multiple traps, connected at last fixture.
Continuous Vent
Vertical extension of a drain serving as vent.
Combination Fixtures
Multiple sinks/trays in one fixture unit.
Combination Waste and Vent System
Horizontal wet venting using a common waste-vent pipe.
Common Vent
Single vent for two or three fixtures; dual vent.
Cross Connection
Physical connection between potable and non-potable systems.
Dead End
Closed pipe end allowing stagnation.
Developed Length
Length along pipe centerline including fittings.
Diameter
Nominal ID, except brass/copper = OD.
Drainage System
Piping conveying sewage or waste to legal disposal.
Dry Vent
Vent that carries air only, no waste.
Effective Opening
Minimum cross-sectional area of outlet (air gap basis).
Existing Work
Plumbing installed and approved prior to alteration.
Fixture Branch
Pipe connecting several fixtures.
Fixture Drain
Pipe from trap to another drain.
Fixture Supply
Pipe connecting fixture to supply branch.
Fixture Units
Numerical load value of fixtures.
Fixture Unit Flow Rate
Flow ÷ 7.5 gpm = unit flow.
Flood Level
Device maintaining tank water level for effective flushing.
Ferrule
Metal sleeve with removable plug for cleaning.
Flush Valve
Tank device for flushing water closets.
Flushometer Valve
Pressure-activated valve delivering fixed water volume.
Grade
Slope of pipe (inch per foot).
Group Vent
Vent serving two or more traps.
Horizontal Pipe
Pipe at more than 45° from vertical.
Invert
Lowest inside portion of a pipe.
Liquid Waste
Waste without fecal matter.
Local Vent Pipe
Removes foul air or vapor from fixture area.
Looped Vent
Circuit vent looping to stack vent.
Lateral
Secondary pipe; sewer receiving building sewer only.
Main
Principal artery of piping system.
Main Sewer
Sewer controlled by public authority.
Main Vent
Primary vent pipe of system.
Plumbing Fixtures
Devices receiving water or discharging waste.
Plumbing System
Entire water supply, drainage, and vent system within property.
Relief Vent
Provides air circulation between drainage and vent systems.
Re-Vent Pipe
Vent connected directly to fixture or waste.
Riser
Vertical supply pipe extending one storey or more.
Rough-In
Plumbing installation before fixtures are set.
Return Bend
180° pipe bend.
Public Sewer
Sewer with equal public connection rights.
Sanitary Sewage
Human excrement + household liquid waste.
Sanitary Sewer
Sewer for sanitary sewage only, no storm water.
Secondary Branch
Branch other than primary building drain.
Sewerage / Sewage Works
Collection to final disposal of sewage.
Siamese Connection
Y-connection for fire hoses.
Standpipe
Vertical water storage pipe, often pressurized.
Side Vent
Vent connected at ≤45° angle.
Soil Pipe
Pipe carrying water closet discharge.
Stack
Vertical main of soil, waste, or vent system.
Stack Group
Fixture layout to minimize venting.
Stack Vent
Extension of stack above highest branch.
Stack Venting
Venting through the soil or waste stack.
Subsoil Drain
Pipe carrying subsurface water only.
Sump
Pit at low point collecting liquid waste.
Trap
Liquid seal preventing back passage of air.
Trap Seal
Vertical depth of retained liquid.
Vent Stack
Vertical pipe for air circulation.
Vent System
Prevents siphonage and back pressure.
Vertical Pipe
Pipe at ≤45° from vertical.
Waste Pipe
Pipe carrying liquid waste only.