Step 1
Provide privacy close curtain
Step 2
Introduce yourself and provide hand hygiene wash hands
Step 3
Verify client identity
Step 4
Ask if they have any allergies
Step 5
Explain what you are doing
Step 6
Select appropriate arm to apply the cuff
Step 7
Place the client in lying or sitting position
Step 8
Support the forearm at the level of the heart with the palm of the hand upward
Step 9
Visualize clients brachial artery brachial artery by removing any clothes or bed linens
Step 10
Choose the appropriate cuff size
Step 11
Palpate the brachial artery, apply cuff with the center extending over the brachial artery, atleast 1 inch above
Step 12
Line the artery marking on the cuff with brachial artery, with the tubing extending from the edge of the cuff. Wrap the cuff aroundthe upper arm snugly and securely.
Step 13
With gauge at eye level, verify that the needle on the aneroid manometer is at the zero mark
Step 14
palpate the brachial artery
Step 15
Tighten the screw valve on the pump and inflate cuff, continue to palpate the brachial artery until it is no longer palpable.
Step 16
Deflate the cuff, wait 1 minute, leave cuff in place
Step 17
Position yourself no more than 3 ft away from gauge
Step 18
clean earpieces, bell, and diaphragm of the stethoscope with an alcohol pad
Step 19
Place the earpiece in your ears and the diaphram firmly over brachial artery
Step 20
Ensure that the stethoscope is not touching clothing or the cuff
Step 21
Tighten the screw valve on the air pump and inflate the cuff, pumping the pressure to 30mm Hg over the estimated systolic pressure
Step 22
Open the valve and slowly release the air, dropping the gauge about 2 to 33 mm
Step 23
Identify the number on the gauge when the first faint clear sound is heard which slowly increases in intensity
Step 24
Continue to release the air until the sound completely disappears - note number on gauge
Step 25
Deflate and remove the cuff
Step 26
position client comfortably and cover
Step 27
Clean the bell and diaphragm
Step 28
Ensure that the client is in a safe position with call light in reach
Step 29
Compare findings with the clients baseline