The instrument specifically used for collecting a fecal sample directly from the animal's rectum is a:
fecal extractor
fecal spoon
fecal loop
fecal scoop
fecal loop
In regard to the care and maintenance of a compound microscope, it is important to use lens cleaners, like xylene and methanol, sparingly for all of the following reasons, except:
Xylene is carcinogenic
Lens cleaners are solvents, which may loosen the adhesive that holds the lens in place
Many lens cleaners are flammable and toxic
These chemicals are costly
these chemicals are costly
Which blood chemistry unit uses test cartridges, can be held in the palm of your hand, and will run blood gases among other tests?
VetScan
Reflovet
Lasercyte
I-stat
I- stat
Which of the following would not be an acceptable action if a control value is out of range?
Ignore the result, it is a simple outlier
Call the technicial representative from the company
Repeat the test using the same reagent
Repeat the test using a new reagent
Ignore the result, it is a simple outlier
A box of reagents for blood chemistry analysis labeled for storage at 8 degrees C can be safely stored:
freezer
at room temp
refridgerator
incubator
refridgerator
A Wood's lamp is used to examine for the presence of:
demodex
scabies
ringworm
pinworm
ringworm
Veterinary reference ranges for blood chemistry values:
Are generally established by each individual veterinary clinic
Include values from both diseased and normal animals
Often come with an analyzer and have been established by the company
Are helpful to refer to but are not necessary
Often come with an analyzer and have been established by the company
Calibration standards for chemistry analyzers are:
not used anymore
used in the same way as a control sera
probably used in the manufacturer
used routinely at the clinic
probably used in the manufacturer
The counting device used to do quantitative counts of parasite eggs is the:
Micrometer
TS meter
McMaster chamber
Fecalyzer
McMaster chamber
The best way to decrease light intensity in a microscope other than to turn the light source down is to:
Open the diaphragm
change the ocular
move the condenser down
move to a lower lens oower
move the condenser down
Blood tubes should be counterbalanced and centrifuged for ____minutes at _____rpm.
2; 1000
5; 1000
10, 2000
15, 2000
10; 2000
The refractometer is used to determine which value?
Hematocrit
Total protein
Hemoglobin
Erythrocyte count
total protein
The temperature of a bacterial incubator would most likely be:
4 degrees C
25 degrees C
37 degrees C
56 degrees C
37 degrees C
The temperature that must be reached in an autoclave to destroy microorganisms is:
110 degrees C
121 degrees C
170 degrees C
240 degrees C
121 degrees C
A 95% sensitivity in reference to a serology test kit refers to:
Effects of other influences on test results
Ability of test to identify diseased patient's serum properly
Ability of test kit to give accurate results if stored properly
How easily a test can be run
Ability of test to identify diseased patient's serum properly