the proper angle for setting up a ladder is to place the base at an_________ ( the working length of the ladder )
quarter
The government organization whose purpose is to set and enforce work site safety and health standards is
OSHA
In General, a beginning trades person with little or no experience in the electrical field is know as
An apprentice
All electrical equipment must be considered ______ before working on it
energized
If the scale on a blueprint indicates 1/8 inch equals 1´ then a line that measures 10 inches would indicate a site measurement
80 feet
if the lighting requirement is 3 volt amps per square foot and a home is 40 feet by 90 feet the required volt-amps for lighting would be
LwA = the answer so 10,800 volt-amps
Which of the following hammers is most commonly used in electrical construction
claw
what are industrial screwdriver blades made of
Tempered Steel
All power tools should be grounded and must have a 3 prong cord unless they are approved
double insulated tools
power tools should be carried by the
Handle
when working on a construction site power tools should only be used if they are plugged into an
GFCI
an ohmmeter is used to measure
resistance
which of the following is used to measure current
Ammeter
What is the most commonly used communication cable in residential voice/data applications
CAT 5E & 7
what type of cable has the largest amount of potential bandwidth ?
fiber optic cable
flexible metal conduit should be supported within _______ from an outlet
12 inches
According to the NEC, EMT conduit must be supported every
10 feet
Finish conduit is produced in nominal _____ lengths
10 foot
which conduit need to be threaded and is the thickest
RMC ( rigid metal conduit )
Double insulated tools are designed to prevent
Electrical Shock
The minimum amount of free wire that must be left in a work box is
6 inches
what type of cable is used for service entrances
SE cable (service entrance cable)
Non-metallic sheathed cable must be supported ______from every outlet or junction box
12 inches
What kind of special screws are sued when attaching receptacles and switches to a box
captive
Outlet boxes that are the sole support for paddle fans must be able to support fans that weigh up to
70 pounds
In order to control a light from four locations, which of the following switches must be use ?
two 3-ways and two 4-way
Which of the following green technology utilizes wind to produce electricity
Wind Mill
The NEC requires two grounding electrode rods to be driven into the ground a minimum of _______ apart
6 feet
What is the minimum distance between straps on service entrance conductors
30 inches
What is the minimum working space width required at the service panel ?
30 inches
A surface type meter base mounted in a wet location must be mounted so that there is an air space between the meter base and mounting surface. What is the minimum air space ?
1/4
Service conductors installed as open conductors should have a clearance of not less than___ from doors or windows designed to open ?
36 inches
A minimum clearance of _____ must be maintained between overhead service conductors and residential properties, driveways, and commercial areas not subject to truck traffic
12 feet
Fora one family dwelling the service disconnecting means should have a minimum rating of ______or greater
100 amps
The NEC is based on
NFPA
According the to NEC, continuous load is where the maximum current is expected current is expected to continue for ______ or more
3 hours
The national Electrical code term "accessible" means that an electrical box can be
removed without damage to the building