the proper angle for setting up a ladder is to place the base at an_________ ( the working length of the ladder )

quarter

2
New cards

The government organization whose purpose is to set and enforce work site safety and health standards is

OSHA

3
New cards

In General, a beginning trades person with little or no experience in the electrical field is know as

An apprentice

4
New cards

All electrical equipment must be considered ______ before working on it

energized

5
New cards

If the scale on a blueprint indicates 1/8 inch equals 1´ then a line that measures 10 inches would indicate a site measurement

80 feet

6
New cards

if the lighting requirement is 3 volt amps per square foot and a home is 40 feet by 90 feet the required volt-amps for lighting would be

LwA = the answer so 10,800 volt-amps

7
New cards

Which of the following hammers is most commonly used in electrical construction

claw

8
New cards

what are industrial screwdriver blades made of

Tempered Steel

9
New cards

All power tools should be grounded and must have a 3 prong cord unless they are approved

double insulated tools

10
New cards

power tools should be carried by the

Handle

11
New cards

when working on a construction site power tools should only be used if they are plugged into an

GFCI

12
New cards

an ohmmeter is used to measure

resistance

13
New cards

which of the following is used to measure current

Ammeter

14
New cards

What is the most commonly used communication cable in residential voice/data applications

CAT 5E & 7

15
New cards

what type of cable has the largest amount of potential bandwidth ?

fiber optic cable

16
New cards

flexible metal conduit should be supported within _______ from an outlet

12 inches

17
New cards

According to the NEC, EMT conduit must be supported every

10 feet

18
New cards

Finish conduit is produced in nominal _____ lengths

10 foot

19
New cards

which conduit need to be threaded and is the thickest

RMC ( rigid metal conduit )

20
New cards

Double insulated tools are designed to prevent

Electrical Shock

21
New cards

The minimum amount of free wire that must be left in a work box is

6 inches

22
New cards

what type of cable is used for service entrances

SE cable (service entrance cable)

23
New cards

Non-metallic sheathed cable must be supported ______from every outlet or junction box

12 inches

24
New cards

What kind of special screws are sued when attaching receptacles and switches to a box

captive

25
New cards

Outlet boxes that are the sole support for paddle fans must be able to support fans that weigh up to

70 pounds

26
New cards

In order to control a light from four locations, which of the following switches must be use ?

two 3-ways and two 4-way

27
New cards

Which of the following green technology utilizes wind to produce electricity

Wind Mill

28
New cards

The NEC requires two grounding electrode rods to be driven into the ground a minimum of _______ apart

6 feet

29
New cards

What is the minimum distance between straps on service entrance conductors

30 inches

30
New cards

What is the minimum working space width required at the service panel ?

30 inches

31
New cards

A surface type meter base mounted in a wet location must be mounted so that there is an air space between the meter base and mounting surface. What is the minimum air space ?

1/4

32
New cards

Service conductors installed as open conductors should have a clearance of not less than___ from doors or windows designed to open ?

36 inches

33
New cards

A minimum clearance of _____ must be maintained between overhead service conductors and residential properties, driveways, and commercial areas not subject to truck traffic

12 feet

34
New cards

Fora one family dwelling the service disconnecting means should have a minimum rating of ______or greater

100 amps

35
New cards

The NEC is based on

NFPA

36
New cards

According the to NEC, continuous load is where the maximum current is expected current is expected to continue for ______ or more

3 hours

37
New cards

The national Electrical code term "accessible" means that an electrical box can be

removed without damage to the building