1/213
Looks like no tags are added yet.
Name | Mastery | Learn | Test | Matching | Spaced |
---|
No study sessions yet.
US-Metric Conversion of 1in
2.5 cm
Binding Energy of K shell
69.5 keV
Binding Energy of L shell
12 keV
Binding Energy of M shell
3 keV
Binding Energy of N shell
1 kEV
Quality Factor of X-Ray
1
Quality Factor of Gamma Ray
1
Quality Factor of Beta
1
Quality Factor of Alpha
20
Quality Factor of fast Neutrons
10
Ionization Chamber detects
1 mR/hr to Thousands of R/hr
Geiger-Muller counter detects
> 100 mR/hr
Film Badge detects
10 mrem to 500 rem, 0.1 mSv to 5 Sv
OSL detects
1 mrem - 1000 rem, 0.01 mSv - 10 Sv
Thermoluminescent Dosimeter detects
1.3 x 10^-6 c/kg
Pocket Ionization Chamber detects
0 - 200 mR
Dose Equivalent Limit: General Public
0.5 rem/yr, 5 mSv/yr
Dose Equivalent Limit: General Public report #
116
Dose Equivalent Limit: Occupational Worker
5 rem/yr, 50 mSv/yr
Dose Equivalent Limit: Occupational Worker report #
116
Dose Equivalent Limit: Radiography Student >18
0.1 rem/yr, 1 mSv/yr
Dose Equivalent Limit: Radiography Student report #
116
Dose Equivalent Limit: Lifetime Occupational
1 rem x age, 10 mSv x age
Dose Equivalent Limit: Lifetime Occupational report #
116
Dose Equivalent Limit: Occupational Selective Doses: Lens of Eye
15 rem/yr, 150 mSv/yr
Dose Equivalent Limit: Occupational Selective Doses: Lens of Eye report #
116
Dose Equivalent Limit: Occupational Selective Doses: Skin/Hands/Feet
50 rem/yr, 500 mSv/yr
Dose Equivalent Limit: Occupational Selective Doses: Skin/Hands/Feet report #
116
Dose Equivalent Limit: Pregnant Worker: Gestation
0.5 rem/gestation, 5 mSv/gestation
Dose Equivalent Limit: Pregnant Worker: Gestation report #
116
Dose Equivalent Limit: Pregnant Worker: Monthly
0.05 rem/month, 0.5 mSv/month
Dose Equivalent Limit: Pregnant Worker: Monthly report #
116
Dose Equivalent Limit: Fetal Dose: Yearly
15 rem/yr, 150 mSv/yr
Dose Equivalent Limit: Fetal Dose: Yearly report #
116
Dose Equivalent Limit: Fetal Dose: Gestation
0.5 rem/gestation, 5 mSv/gestation
Dose Equivalent Limit: Fetal Dose: Gestation report #
116
Dose Equivalent Limit: Fetal Dose: Monthly
0.05 rem/month, 0.5 mSv/month
Dose Equivalent Limit: Fetal Dose: Monthly report #
116
Collimator SID accuracy
SID accurate within 2% of indicated SID
SID accuracy report #
116
Manual Collimator SID accuracy
within 2% of SID
PBL Collimator SID accuracy
within 1-2% of SID
Manual Collimator SID accuracy report #
116
PBL Collimator SID accuracy report #
116
Aprons (recommended)
0.5 mm Pb
Aprons (recommended) report #
102
Aprons (minimum)
n/a
Aprons (minimum) report #
n/a
Neck/Thyroid (recommended)
0.5 mm Pb
Neck/Thyroid (recommended) report #
102
Neck/Thyroid (minimum)
n/a
Neck/Thyroid (minimum) report #
n/a
Gloves (recommended)
0.25 mm Pb
Gloves (recommended) report #
102
Gloves (minimum)
n/a
Gloves (minimum) report #
n/a
Eyeglasses (recommended)
0.35 mm Pb
Eyeglasses (recommended) report #
102
Eyeglasses (minimum)
n/a
Eyeglasses (minimum) report #
n/a
Flouro Drape (recommended)
0.5 mm Pb
Flouro Drape (recommended) report #
102
Flouro Drape (minimum)
0.25 mm Pb
Flouro Drape (minimum) report #
102
Bucky Cover (recommended)
0.5 mm Pb
Bucky Cover (recommended) report #
102
Bucky Cover (minimum)
0.25 mm Pb
Bucky Cover (minimum) report #
102
Glass Window (recommended)
1.5 mm Pb
Glass Window (recommended) report #
102
Glass Window (minimum)
n/a
Glass Window (minimum) report #
n/a
Inherent Filtration standards
0.5 mm Al
Inherent Filtration standards report #
102
Total Filtration: Tube Capacity <50 kVp
0.5 mm Al
Total Filtration: Tube Capacity >50 kVp report #
102
Total Filtration: Tube Capacity 50-70 kVp
1.5 mm Al
Total Filtration: Tube Capacity 50-70 kVp report #
102
Total Filtration: Tube Capacity 70+ kVp
2.5 mm Al
Total Filtration: Tube Capacity 70+ kVp report #
102
SSD for all traditional X-Rays except dental
minimum 12 in, 30 cm
SSD for all traditional X-Rays except dental report #
102
Portables: Source to Skin Distance
minimum 12 in, 30 cm
Portables: Source to Skin Distance report #
102
Collimator to Skin Distance
minimum 6 in, 15 cm
Fluoroscopy (Fixed) Source to Tabletop Distance
minimum 15 in, 38 cm
Collimator to Skin Distance report #
102
Portable Fluoroscopy Source to Tabletop Distance
minimum 12 in, 30 cm
Fluoroscopy (Fixed) Source to Tabletop Distance report #
102
Portable Fluoroscopy Source to Tabletop Distance report #
102
Cord on Portable
6 ft, 72 in, 180 cm, 2 m
Cord on Portable report #
102
Cord on Fixed Unit
18 in, 45 cm
Cord on Fixed Unit report #
102
Scattered Beam
1/1000, 0.001, 0.1% the intensity of the primary beam 1 meter from patient
Scattered Beam report #
102
Tabletop Exposure Rate Flouro
maximum 10 R/min, 5 R/min @ 1 m
Tabletop Exposure Rate Flouro report #
102
Leakage Radiation
maximum 100 mR/hr @ 1 m, 1 mGy/hr @ 1 m
Leakage Radiation Report #
102