1/131
Looks like no tags are added yet.
Name | Mastery | Learn | Test | Matching | Spaced |
---|
No study sessions yet.
National Building Code of the Philippines
PD 1096
Declaration of Policy of PD 1096
It is the policy of the State declared to safeguard life, health, property and public welfare, consistent with the principles of sound environment management and control. Provides for all buildings and structures, a framework of minimum standards and requirements to regulate and control their location, site, design, quality of materials, construction, use, occupancy and maintenance.
Economic & Social Housing Project
It is the exception to the scope and application of the National Building Code known as BP 220
DPWH Secretary
It is the official who approves the applicable and consistent provisions of the allied professional codes and other government agency codes that shall serve as referral codes of the PD 1096 & IRR
Addition
It is any new construction which increases the height and/or floor area of existing buildings or structures
Agency of the Government
It refers to any of the various units of the government including a department, bureau, office, instrumentality or government owned or controlled corporation.
Alteration
It is the works in buildings or structures involving changes in the materials used, partitioning, location or size of openings, structural parts, existing utilities and equipment but does not increase the building height and/or floor area.
Application Forms
It is the preformatted prescribed application form duly accomplished and notarized by respective design professional with validation matrices related to other building rules and regulations.
Applicant
It is also known as the permittee. It is any person, firm, partnership, corporation, head of government or private institution of any character applying for the issuance of permits and certificates.
Building Official
It is the executive officer of the OBO appointed by the secretary
Building Permit
It is a document issued by the building official to owner or
applicant to proceed with construction.
Construction
It is all on-site work done in the site preparation, excavation, foundation, assembly of al components and installation of utilities, machineries and equipment of building and structures.
Conversion
It is a change in the use of occupancy of buildings or structures or any portion which has different requirements
Demolition
It is the systematic dismantling of destruction of a building or structure in whole or in part.
Department of Public Works and Highways
DPWH
Moving
It is the transfer of building or structures or portions from the original location or position to another, either within the same lot or to a different one.
Office of the Building Official
It is the office authorized to enforce the provisions of the building code and rules and regulations in the field as well as the enforcement of orders and decisions made.
Referral Codes
It is the applicable provisions of the various agency and technical professional codes that are supplementary to the code.
Renovation
It is any physical change made on buildings or structures to increase the value, quality, and/or to improve the aesthetic.
Repair
It is the remedial work done on any damaged or deteriorated portions of a building or structure to restore it to its original condition.
Secretary
He is the head or the chief executive officer of the DPWH
National Building Code Development Office
NBCDO
National Building Code Development Office
They shall serve as the technical staff of the secretary. They assist in administration and enforcement of the provisions, review evaluate and take action on various technical and legal problems, conduct seminars and workshops and undertake other duties assigned by the secretary.
Traditional Indigenous Family Dwelling
It means a dwelling intended for use and occupancy by a family of the owner only and constructed of native materials such as bamboo, nipa, logs or lumber of which does exceed a total cost of P15,000
P 10,000
The secretary or his duly authorized representative may prescribe and impose fines not exceeding this amount in the imposition of administrative fees.
P 5,000
It is the amount of fine for light violations of the code.
P 8,000
It is the amount of fine for less grave violations of the code.
P 10,000
It is the amount of fine for grave violations of the code.
10% of the Building Permit Fee
It is the percentage of the amount of penalty or surcharge for excavation for foundation without any permit.
25% of the Building Permit Fee
It is the percentage of the amount of penalty or surcharge for construction of foundation including pile driving and laying of reinforcing bars without any permit.
50% of the Building Permit Fee
It is the percentage of the amount of penalty or surcharge for the construction of superstructure up to 2.00 meters above established grade without any permit.
100% of Building Permit Fee
It is the percentage of the amount of penalty or surcharge for the construction of superstructure higher than 2.00 meters without any permit.
30 Days
It is the number of days a surcharge of 25% of the inspection fee will be imposed if there is a failure to pay the annual inspection fee.
2 Years
It is the maximum number of years prescribed in the penal provisions to any person, firm or corporation for violation of the provisions of the code or commit any act declared to be unlawful.
P 20,000
It is the maximum amount in pesos prescribed in the penal provisions to any person, firm or corporation for violation of the provisions of the code or commit any act declared to be unlawful.
Dangerous Buildings
It is a building declared as structurally unsafe or not provided with safe egress or which constitutes to a fire hazard or are otherwise dangerous to human life.
Ancillary Permits
These are duly signed and sealed by the corresponding professionals and the plans specifications shall be submitted together with the duly notarized application for the Building Permit.
Accessory Permits
These are issued by the Building Official for accessory parts of the project with very special functions or use which are indicated in the plans and specification that accompany the Building Permit application.
Geodetic Engineer
He is the professional responsible for signed and sealed lot survey plans.
Civil Engineer
He is the professional responsible for signed and sealed civil or structural documents
1 year
It is the number of years a building permit issued shall expire and become null and void if the building or work does not commence.
120 days
The building permit issued shall expire and become null and void if the building or work is suspended or abandoned after a number of days.
15 days
Within this number of days from the date of receipt of advice of the non-issuance, suspension or revocation of permits, the application or permittee may file an appeal with the Secretary.
Type 1
It is the type of construction made of wood construction.
Type 2
It is the type of construction made of wood construction with protective fire-resistant materials and one-hour fire-resistive throughout, except, that permanent non-bearing partitions may use fire-retardant treated wood within the framing assembly with one-hour resistivity.
Type 3
It is the type of construction made of masonry and wood construction and the building is of one-hour fire-resistive throughout and exterior walls are of combustible fire-resistive construction
Type 4
It is the type of construction made of steel, iron, concrete, or of masonry construction and walls, ceiling and permanent partitions are of combustible, fire-resistive constriction.
Type 5
It is the type of construction that is of four-hour fire-resistive throughout and the structural elements are of steel, iron, concrete or masonry construction
Fire Zones
It is the area within which only certain type of building / structures are permitted to be constructed based on their use or occupancy, type of construction and resistance to fire.
Group A
It is the classification of occupancy for residential dwellings.
Division 1
It is the division of Group A occupancy that includes residential building / structures for exclusive use of single family occupants including school or company staff housing.
Division 2
It is the division of Group A occupancy that includes residential building / structures for exclusive use of occupants not exceeding 10 personals including single attached or duplex or townhouses.
Group B
It is the classification of occupancy for Residential, Hotels and Apartments
Group C
It is the classification of occupancy for Education and Recreation
Group D
It is the classification of occupancy for Institutions such as mental hospitals, nurseries for full-time care of children or nursing homes for ambulatory patients.
Group E
It is the classification of occupancy for business use and mercantile use such as gasoline filling and service stations, wholesale and retail stores and aircraft hangars and open parking garages.
Group F
It is the classification of occupancy for industrial use such as ice plants, power plants, pumping plants, cold storage, creameries and the like.
Group G
It is the classification of occupancy for storage and hazardous use such as storing and handling of highly flammable material, wood working establishments, repair garages and aircraft repair hangars
Group H
It is the classification of occupancy for assembly building with a stage and an occupant load of less than 1000.
Group I
It is the classification of occupancy for assembly building with a stage and an occupant load of more than 1000
750 MM
It is the clear width of stairs
200 MM
It is the maximum height of a riser
200 MM
It is the minimum run of a thread.
2.40 MTRS
It is the minimum ceiling height for habitable rooms provided with artificial ventilation.
2.70 MTRS
It is the minimum ceiling height of the first story for a multi-story building.
2.40 MTRS
It is the minimum ceiling height of the second story for a multi-story building.
2.10 MTRS
It is the minimum ceiling height for all succeeding story with an unobstructed typical head-room clearance.
1.80 MTRS
It is the minimum ceiling height for mezzanine floors.
6 SQ MTRS
It is the minimum room size for habitation with a least dimension of 2 MTRS
3 SQ MTRS
It is the minimum room size of a kitchen with a least dimension of 1.50 MTRS.
1.20 SQ MTRS
It is the minimum room size of a toilet and bath with a least dimension of 900 MM
3 CU MTRS
It is the minimum air space provided for school rooms with 1 SQ MTR of floor area per person.
12 CU MTRS
It is the minimum air space provided per person for workshops, factories and offices.
14 CU MTRS
It is the minimum air space per person provided for habitable rooms
National Standards for Drinking Water Standards
The quality of drinking water from meteoric surface or underground sources shall conform to the criteria set in this latest approved standards.
Water Code of the Philippines
PD 1067
Revised National Plumbing Code of the Philippines
The water piping installation of water supply and distribution to each fixture including the wastewater drainage with proper venting inside the building and premises, shall conform to the provision of this code.
3 MTRS
It is the minimum clearance between the established grade of the street and/or sidewalk and lowest under surface of any part of the balcony.
3 MTRS
It is the clear height of an arcaded pedestrian walkway.
Marquee
It is also known as a canopy. It is a permanent roofed structure above a door attached to and supported by the building and projecting over a wall or sidewalk.
300 MM
It is the horizontal clearance between the outermost edge of the marquee and the curb line.
3 MTRS
It is the vertical clearance between the pavement or ground line and the undersurface of any part of the marquee.
Awning
It is a movable shelter supported entirely from an exterior wall of a building and of a type which can be retracted, folded or collapsed against the face of a supporting building.
300 MM
It is the horizontal clearance between the awning and the curb line.
2.40 MTRS
It is the vertical clearance between the undermost surface of the awning and the pavement or ground line.
Veneer
It is a non-structural facing of brick, concrete, tile, metal, plastic, glass or other similar materials attached to a backing or structural components of a building for the purpose of ornamentation, protection or enclosure.
900 MM
It is the minimum width of an exit door
2 MTRS
It is the minimum height of an exit door
1.20 MTRS
It is the maximum door leaf width of an exit door.
1.10 MTRS
It is the minimum width for every corridor or exit balcony.
1.10 MTRS
It is the minimum width of a stairway serving an occupant load of more than 50
900 MM
It is the minimum width of a stairway serving an occupant load of less than 50
750 MM
It is the minimum width of a stairway serving a private stairway with an occupant load of less than 10
1.20 MTRS
It is the minimum dimension of every landing measured in the direction of travel equal to the width of the stairway when the stairs has a straight run.
3.60 MTRS
It is the minimum vertical distance between landings.
800 MM
It is the minimum height of the handrail above the nosing tread.
900 MM
It is the maximum height of the handrail above the nosing tread.
2 MTRS
It is the minimum headroom clearance for stairway.
800 MM
It is the minimum width of an aisle serving only one side.