20 Terms

1
New cards

Free and Accessible

In all cases such joints shall be -

2
New cards

25.4 mm

Cast iron soil pipe and other similar joints shall be firmly packed with oakum or hemp and filled with molten pig lead to a depth of not less than -

3
New cards

Teflon tape

Is acceptable for use on male threads, only if screwed pipe joint.

4
New cards

Gastight and Watertight connections

Pressure test on joints and connections of pipes and fittings in the plumbing system shall be required to ensure -

5
New cards

80 minimum wall thickness

In threaded joints, threaded plastic pipe shall be Schedule -

6
New cards

Counterflashing

Shall not restrict the required internal cross-sectional area of the vent.

7
New cards

3.2 mm

In caulked joints, the finished joint shall not extend more than ____ below the rim of the hub.

8
New cards

19mm

Wiped lead joints shall have an exposed surface on each side of a joint not less than -

9
New cards

Solder and Sweat joints

Joints in copper tubing shall be made by the appropriate use of approved brass or copper fittings.

10
New cards

0.2%

Solders and fluxes with a lead content which exceeds ___ are prohibited in piping systems used to convey potable water.

11
New cards

Building Sewers

Except for repairs and connections to existing lines constructed with such joints, cement mortar joints are prohibited on new-

12
New cards

Shall be lapped and the assembly shall be fuse together to form a uniform weld at least as thick as the lead sheets being joined.

Burned lead joints

13
New cards

Joints between asbestos cement pipe and other approved pipe shall be made by means of an approved -

Adapter coupling

14
New cards

Plastic pipe and fittings designed to be joined by solvent cementing shall comply with appropriate IAPMO Installation Standards.

Solvent cement plastic pipe joints

15
New cards

Molded rubber coupling joints

When pipe is joined by means of molded neoprene rubber coupling joints, such joints shall conform to approved standards and shall not be considered as slip joints.

16
New cards

Slip joints

Are exposed for faculty in maintenance.

17
New cards

Fixture carrier fitting

Wall-mounted water closet fixtures shall be securely bolted to an approved -

18
New cards

76 mm, 102mm

The enlargement of __ closet bend or stub to shall not be ____ considered an obstruction.

19
New cards

Joints at the roof around pipes, ducts or other appurtenances shall be made watertight by the use of lead, copper, galvanized iron, or other approved -

Flashing material

20
New cards

Brass or cast iron body cleanouts shall not be used as a -

Reducer or Adapter.