35 Terms

1
New cards

Dark Adaptation

Adjustment of eyesight in low light conditions.

2
New cards

Vignetting

Edge distortion from concave input screen.

3
New cards

Carriage Arm

Supports equipment over the x-ray table.

4
New cards

The image intensifier tube is designed to electronically amplify of an image.

brightness

5
New cards

Fluoroscopy

Dynamic examination for active diagnosis.

6
New cards

Getter

Ion pump removing ions during imaging process.

7
New cards

What should shut to viewing image size when magnifying?

Collimation

8
New cards

the greater voltage applied to the electrostatic lenses the _ the acceleration.

greater

9
New cards

Typical X-ray Tube mA

Operates between 50-1200 mA.

10
New cards

Electrostatic Lenses

Accelerate and focus electrons in imaging.

11
New cards

most fluoro systems are capable of bit processing.

8

12
New cards

Flat Panel Detector Benefits

Reduction in C-arm size and weight

improve positioning flexibilty

non vignetting/ pin cushioning

decrease pt dose

improve

13
New cards

Multiple Detector System

Involves image capture, readout of data, and clearing of DELS for next exposure

14
New cards

Table Top Exposure Limit should not exceed

10 R/min

15
New cards

Input Fluorescent Screen Shape

concave

16
New cards

Interrogation Time

Time for generator to reach KVP and MAS.

17
New cards

Flux Gain

Increase in light photons from conversion efficiency.

18
New cards

magnification of an image viewed with a screen diameter of 12 is using a 5 diameter area of magnification would be?

19
New cards

high power generator

pulse progressive mode is achieved by using high power generators

20
New cards

Quantum Mottle Reduction

Increase mA

21
New cards

electrons that strike the screen are converted into what color light photons?

green

22
New cards

Total Brightness Gain

measurement of the increase in image intensity achieved by an II tube

23
New cards

Shape Distortion

distortion that is caused by geometric problems in the shape of the II tube

24
New cards

Lead Equivalent for Radiologists and techs

0.5mm Pb/eq

25
New cards

Fluoro Alarm Time

5 minutes.

26
New cards

II tubes can be designed to the image electronically by changing voltage on the lenses.

magnify

27
New cards

Minification Gain

increase in brightness of intensity, not in quality of the number of photons

28
New cards

Automatic Brightness Control

Maintains image brightness and contrast.

29
New cards

highest energy scatter at greater than degrees angle to the incident beam

90 degrees

30
New cards

Bucky Slot Lead Coverage

Covered by 0.25mm Pb for safety.

31
New cards

Total Brightness Gain

Minification gain x flux gain =

32
New cards

(AGC)

automatic gain control

33
New cards

Contrast is controlled by increasing _ of the video signal

amplitude

34
New cards

Brightness Gain deteriates as much as ____ % per year as input and out put screens age

10%

35
New cards

Minification Gain Calculation

(Input diameter^2)/(Output diameter^2) =