According to bp344, what is the minimum clear headroom required for walkways?
2.00m minimum clear headroom
According to the illustration for rest stops, what is the maximum distance between rest areas along lengthy walkways?
12.00m
What is the required clearance between a wall-mounted handrail and the wall itself?
At least 50mm clearance
Based on the dropped curb illustration, what is the minimum width for the ramp portion of a dropped curb?
0.90m
According to the illustration for rest stops, what is the maximum distance between rest areas along a lengthy walkways?
12.00m
Based on the illustration for gratings on walkways, what is the maximum allowable opening size in one direction?
13mm
In the handrail height illustration, what is the lower required handrail height for ramps and stairs?
0.70m
In the handrail dimensions illustration, what is the required handrail diameter range shown?
30mm to 50mm
According to the illustration: what accessibility feature must be added in the middle of this ramp under bp344
Intermediate handrails at the center (double J-type supports recommended)
What is the rule under bp344 for changes in level when a dropped sidewalk, curb ramp, or elevator is provided?
In that case, a ramp is not required
What is the minimum size of the level area in the vestibule to comply with bp344
1800mm depth x 1800mm width
According to bp344, do handrails on ramps need to be made of special materials or have special surface properties?
Yes, handrails shall be made of slip-resistant material with continuous gripping surface, no sharp edges or projection
According to bp 344, is a ramp required for any change in level in buildings?
Yes, unless there is a dropped sidewalk, curb ramp, elevator, or other mechanical device
Bonus
Bonus
Under bp 344, what is the maximum interval (in length) between landings for a long ranp that exceeds 10.50m in total length?
Landings must be provided (minimum length 1800mm), no specified “interval”, but requirements triggers when total length is > 10.50m
What is the minimum dimension of this level area according to bp344? (Ramp dimension)
1800mm depth (and width on ramp width) at both top and bottom ramp
What is the minimum clear width for accessible routes (like walkways / corridors) under bp344 to allow mobility aids?
150mm (for a walkway/corridor) providing a usable accesible
Under bp344, if a ramp leads down toward an area with vehicular traffic and has a rise greater than 200mm, what additional safety feature is required?
A railing across the full width of the lower end of the ramp, at least 1800mm from the foot of the ramp
According to bp344, can a ramp be substituted by stairs when there is a change in level?
No, change in level requires a ramp, unless there is a dropped sidewalk, curb ramp, elevator, or mechanical device
What are the 2 main surface requirements for accessible corridors under bp344?
Floor must be level and stable, floor surface mist be slip-resistant under wet and dry conditions.
For a building under bp344, what is the minimum requirement for accessible entrance points?
At least 1 accessible entrance from arrival/departure points to interior lobby
If there is no change in elevation, is a ramp still required under bp 344
No, ramp is not required if there is no change in elevation, ramp is only for changes in level
What must the walls or transparent glass panels at entrances have if they are frameless and transparent according to bp 344
Must have a horizontal or graphical patterns woth at least 30% luminance contrast between 800mm and 1500mm above the floor to prevent collision
Under bp344, should accessible entrances and exits be protected from weather (rain, sun)?
Yes, they should be provided with full weather protection
What visual safety feature is needed on transparent glass panels to meet bp 344
Horizontal or graphical patterns with at least 30% luminance contrast between 800mm to 1500 mm above the floor.
Under bp344, what is the minimum width for accessible routes connecting parking, sidewalks, and building entrances (walkways)?
Minimum 1500mm (corridor/walkway width) to allow mobility aids, although ramp clear width is 1200mm
What must be added at the center of this ramp as per BP344’s appendix
Intermediate handrails (double J type supports are recommended) when ramp is >_ 3000mm wide
According to bp344, what are the requirements for surface materials for floors and ground surfaces un accessible buildings or walkways
They should be slip-resistant under wet and dry conditions, and must be stable and level
What is the minimum curb height required on a ramp under BP344?
Minimum of 100mm
Under bp344, does a ramp always need a landing if gradient and length are within limits?
Not necessarily, landings are required when ramp total length exceeds 10.50m (or in special cases as table indicates)
What must be provided along this ramp according to bp344?
Intermediate landings with minimum length of 1800mm
According to bp344, are transparent glass doors allowed at entrances? If yes, with what condition
Yes but glass panels must have a horizontal or graphical patterns with >_30% luminance contrast between 800mm and 1500mm above the floor
What does bp344 require regarding weather protection for accessible emtrances and exits?
They must have full weather protection (from rain and heat) along accessible routes including stairs, ramps, lifts if any
Illutration based, if this space is a dead-end corridor, whatbis the minimum dimension of turn-about space required under bp-344
1800mm x1800mm turn about space
Illus based, what extra safety elements does this ramp need according to bp344?
A railing accross the full width at the lower end of the ramp, at least 1800mm from the foot of the ramp
According to bp344, what is the minimum clear width for accessible ramps in case of standard construction?
1200mm clear wodth
Illus based, what is the minimum clear level space must be available beyond the door for accesibility under bp344?
1800mm x 1800mm clear level space beyond door (except corridor-side exception)
What specification does bp344 set for surfaces (floors, walkwaysj regarding slip-resistance?
They must be slip resistant in both wet and dry conditions
Under bo344, are ramps the only means to deal with level changes?
No. Level changes may also be handked via dropped sidewalks, curb ramps, elevators, or mechanical devices
Illus based, why is the ramp required here under bp344?
Because there is a change in level and unless there’s a dropped sidewalk, curb ramp, elevator, or mechanical device, a ramp must be provided