bp344- appendix and illustration

0.0(0)
studied byStudied by 0 people
0.0(0)
full-widthCall with Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/39

encourage image

There's no tags or description

Looks like no tags are added yet.

Study Analytics
Name
Mastery
Learn
Test
Matching
Spaced
Call with Kai

No study sessions yet.

40 Terms

1
New cards

According to bp344, what is the minimum clear headroom required for walkways?

2.00m minimum clear headroom

2
New cards

According to the illustration for rest stops, what is the maximum distance between rest areas along lengthy walkways?

12.00m

3
New cards

What is the required clearance between a wall-mounted handrail and the wall itself?

At least 50mm clearance

4
New cards

Based on the dropped curb illustration, what is the minimum width for the ramp portion of a dropped curb?

0.90m

5
New cards

According to the illustration for rest stops, what is the maximum distance between rest areas along a lengthy walkways?

12.00m

6
New cards

Based on the illustration for gratings on walkways, what is the maximum allowable opening size in one direction?

13mm

7
New cards

In the handrail height illustration, what is the lower required handrail height for ramps and stairs?

0.70m

8
New cards

In the handrail dimensions illustration, what is the required handrail diameter range shown?

30mm to 50mm

9
New cards

According to the illustration: what accessibility feature must be added in the middle of this ramp under bp344

Intermediate handrails at the center (double J-type supports recommended)

10
New cards

What is the rule under bp344 for changes in level when a dropped sidewalk, curb ramp, or elevator is provided?

In that case, a ramp is not required

11
New cards

What is the minimum size of the level area in the vestibule to comply with bp344

1800mm depth x 1800mm width

12
New cards

According to bp344, do handrails on ramps need to be made of special materials or have special surface properties?

Yes, handrails shall be made of slip-resistant material with continuous gripping surface, no sharp edges or projection

13
New cards

According to bp 344, is a ramp required for any change in level in buildings?

Yes, unless there is a dropped sidewalk, curb ramp, elevator, or other mechanical device

14
New cards

Bonus

Bonus

15
New cards

Under bp 344, what is the maximum interval (in length) between landings for a long ranp that exceeds 10.50m in total length?

Landings must be provided (minimum length 1800mm), no specified “interval”, but requirements triggers when total length is > 10.50m

16
New cards

What is the minimum dimension of this level area according to bp344? (Ramp dimension)

1800mm depth (and width on ramp width) at both top and bottom ramp

17
New cards

What is the minimum clear width for accessible routes (like walkways / corridors) under bp344 to allow mobility aids?

150mm (for a walkway/corridor) providing a usable accesible

18
New cards

Under bp344, if a ramp leads down toward an area with vehicular traffic and has a rise greater than 200mm, what additional safety feature is required?

A railing across the full width of the lower end of the ramp, at least 1800mm from the foot of the ramp

19
New cards

According to bp344, can a ramp be substituted by stairs when there is a change in level?

No, change in level requires a ramp, unless there is a dropped sidewalk, curb ramp, elevator, or mechanical device

20
New cards

What are the 2 main surface requirements for accessible corridors under bp344?

Floor must be level and stable, floor surface mist be slip-resistant under wet and dry conditions.

21
New cards

For a building under bp344, what is the minimum requirement for accessible entrance points?

At least 1 accessible entrance from arrival/departure points to interior lobby

22
New cards

If there is no change in elevation, is a ramp still required under bp 344

No, ramp is not required if there is no change in elevation, ramp is only for changes in level

23
New cards

What must the walls or transparent glass panels at entrances have if they are frameless and transparent according to bp 344

Must have a horizontal or graphical patterns woth at least 30% luminance contrast between 800mm and 1500mm above the floor to prevent collision

24
New cards

Under bp344, should accessible entrances and exits be protected from weather (rain, sun)?

Yes, they should be provided with full weather protection

25
New cards

What visual safety feature is needed on transparent glass panels to meet bp 344

Horizontal or graphical patterns with at least 30% luminance contrast between 800mm to 1500 mm above the floor.

26
New cards

Under bp344, what is the minimum width for accessible routes connecting parking, sidewalks, and building entrances (walkways)?

Minimum 1500mm (corridor/walkway width) to allow mobility aids, although ramp clear width is 1200mm

27
New cards

What must be added at the center of this ramp as per BP344’s appendix

Intermediate handrails (double J type supports are recommended) when ramp is >_ 3000mm wide

28
New cards

According to bp344, what are the requirements for surface materials for floors and ground surfaces un accessible buildings or walkways

They should be slip-resistant under wet and dry conditions, and must be stable and level

29
New cards

What is the minimum curb height required on a ramp under BP344?

Minimum of 100mm

30
New cards

Under bp344, does a ramp always need a landing if gradient and length are within limits?

Not necessarily, landings are required when ramp total length exceeds 10.50m (or in special cases as table indicates)

31
New cards

What must be provided along this ramp according to bp344?

Intermediate landings with minimum length of 1800mm

32
New cards

According to bp344, are transparent glass doors allowed at entrances? If yes, with what condition

Yes but glass panels must have a horizontal or graphical patterns with >_30% luminance contrast between 800mm and 1500mm above the floor

33
New cards

What does bp344 require regarding weather protection for accessible emtrances and exits?

They must have full weather protection (from rain and heat) along accessible routes including stairs, ramps, lifts if any

34
New cards

Illutration based, if this space is a dead-end corridor, whatbis the minimum dimension of turn-about space required under bp-344

1800mm x1800mm turn about space

35
New cards

Illus based, what extra safety elements does this ramp need according to bp344?

A railing accross the full width at the lower end of the ramp, at least 1800mm from the foot of the ramp

36
New cards

According to bp344, what is the minimum clear width for accessible ramps in case of standard construction?

1200mm clear wodth

37
New cards

Illus based, what is the minimum clear level space must be available beyond the door for accesibility under bp344?

1800mm x 1800mm clear level space beyond door (except corridor-side exception)

38
New cards

What specification does bp344 set for surfaces (floors, walkwaysj regarding slip-resistance?

They must be slip resistant in both wet and dry conditions

39
New cards

Under bo344, are ramps the only means to deal with level changes?

No. Level changes may also be handked via dropped sidewalks, curb ramps, elevators, or mechanical devices

40
New cards

Illus based, why is the ramp required here under bp344?

Because there is a change in level and unless there’s a dropped sidewalk, curb ramp, elevator, or mechanical device, a ramp must be provided