M8L1 & L2- mobile radiograhy and bone densitometry

0.0(0)
studied byStudied by 0 people
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
Card Sorting

1/17

encourage image

There's no tags or description

Looks like no tags are added yet.

Study Analytics
Name
Mastery
Learn
Test
Matching
Spaced

No study sessions yet.

18 Terms

1
New cards

what is the battery in mobile radiographs made out of

lead or nickel cadmium

2
New cards

what ist he kvp and mas in high frequncy mobile units

133 kvp and 200 mas

3
New cards

what is unique abotu the high frequency mobile units

microprocessor circuit increase frequency of the AC to create. nerayl constant potential

4
New cards

bone densitometry

mesuring of bone mineral content and dennsity of the skeletal system

5
New cards

DXA stand for

dual energy xray absorptionmetry

6
New cards

what is DXA

scanning parts using 2 different photon energies to distinguish bone and soft tissue. soft tissue is subtracted from bone and is used to calculate the density of the bone

7
New cards

what are the 2 ways to achieve dual beam energies

k-edge filtered and energy switching system

8
New cards

what is k-edge diltered

primary beam passes through the filters causing the second beam to have a different energy

9
New cards

what is energy switchign system

kVp switching from 100 and 140. Primary beam will have 2 different energies. the peaks are at 40 and 80 kEv

10
New cards

what are common sites to scan for a DXA

femur, hip, spine, and forearm

11
New cards

what are disadvantages of DXA

beam hardeninng and scintillating detector pileup in k-edge filteration system. cross over in k-edge filteration systems

12
New cards

what is beam hardening

thicker body parts absorb lower enrgy photons and high energy photons are left

13
New cards

what does it mean by scintillating detector pileup in k-edge filteration systems

the detector can only process one photon at a time thus others can be missed when the first isnt processed. generally seen in digital detectors

14
New cards

what does it mean by crossover in k-edge filteration systems?

high energy photons are absorbed by the body and thus is read as low energy

15
New cards

is the dose of DXA high or low

low

16
New cards

when doing a DXA system with a array beam multiple detector/fan beam, where is the x-ray tube

below the table

17
New cards

what allows true obejct location to be calculated

Multiview image reconstruction

18
New cards

how is the fan beam system positioned

parallel to long axis of patient and scans inn tranverse pattern across the body