ARCC PEEPEE POOPOO

0.0(0)
studied byStudied by 1 person
0.0(0)
full-widthCall with Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/45

encourage image

There's no tags or description

Looks like no tags are added yet.

Study Analytics
Name
Mastery
Learn
Test
Matching
Spaced
Call with Kai

No study sessions yet.

46 Terms

1
New cards

RA. 9266 is also known as

a. Law to Enhance the Mobility of Disabled Persons

b. National Building Code of the Philippines

c. Fire Code of the Philippines of 2008

d. Architecture Act of 2004

Architecture Act of 2004

2
New cards

B.P. 344 is also known as

a. Law to Enhance the Mobility of Disabled Persons

b. National Building Code of the Philippines

c. Fire Code of the Philippines of 2008

d. Architecture Act of 2004

Law to Enhance the Mobility of Disabled Persons

3
New cards

RA. 9514 is also known as

a. Law to Enhance the Mobility of Disabled Persons

b. National Building Code of the Philippines

c. Fire Code of the Philippines of 2008

Fire Code of the Philippines of 2008

4
New cards

P.D. 1096 is also known as

a. Law to Enhance the Mobility of Disabled Persons

b. National Building Code of the Philippines

c. Fire Code of the Philippines of 2008

d. Architecture Act of 2004

National Building Code of the Philippines

5
New cards

What term is defined under R.A. No. 9266 as the art, science or profession of planning, designing and constructing buildings in their totality taking into account their environment. In accordance with the principles of utility, strength and beauty?

a. Environmental Planning

b. Architecture

c. Civil Engineering

d. Architectural Engineering

Architecture

6
New cards

What term is defined under the Architecture Act of 2004 as a notarized written contract or equivalent public instrument stipulating the scope of services and guaranteeing compensation of such services to be rendered?

a. Contract Documents

b. Service Agreement

c. Service Proposal

d. None of the above

Service Agreement

7
New cards

According to RA. 9266, the Architect is not required to seal all architectural plans, architect's direct supervision drawings, specifications and all other contract documents prepared by or under his/her direct supervision

a. Absolutely True

b. Absolutely False

c. Partially True

d. Partially False

Absolutely False

8
New cards

According to RA. 9266, an architectural partnership or corporation is required to register with the:

a. Securities and Exchange Commission

b. Professional Regulation Commission

c. Both a and b

d. None of the above

Both a and b

9
New cards

When an architect or any person violates the provisions of R.A. 9266 the penalty that can be imposed is/are:

a. P100,000- P5 million fine

b. 6mos-6 years imprisonment

c. both a and b combined

d. all of the above

both a and b combined

10
New cards

As per the Code of Ethical Conduct, what document is used by the Architect to the owner/client that certifies the billing of the contractor?

a. Certificate of Payment

b. Billing Certificate

c. Billing Statement

d. Statement of Account

certificate of payment

11
New cards

According to the Standards of Professional Practice (SPP) Documents, except for SPP Doc. 209, the multiplier shall range from

a. 1.50, 3.00

b. 1.50, 2.00

c. 1.50, 3,50

d. 1.50, 2.50

1.50, 2.50

12
New cards

As per the Standards of Professional Practice, if the Project Construction Cost (PCC) is Php 1, 000.000.00 and the professional fee of the architect Is 10% of the PCC, how much should the owner pay the architect after submission of the contract documents?

a. Php 900,000.00

b. Php 500,000.00

c. Php 850.000.00

d. Php 1,000,000.00

e. Php 100,000.00

Php 900,000.00

13
New cards

As per P.D. No, 1096, the max. distance of egress for buildings with no fire protection system and with fire protection system respectively, are:

a. 46 and 61

b. 45 and 60

c. 61 and 46

d. 60 and 45

45 and 60

14
New cards

As per RA. No, 9514, the max. distance of egress for buildings with no fire protection system and with fire protection system respectively, are:

a. 46 and 61

b. 45 and 60

c. 61 and 46

d. 80 and 45

46 and 61

15
New cards

In order to comply with the provisions of R.A. No. 9514 and P.D. No, 1096 in relation to the requirements for max. distance of egress for buildings with no fire protection system and with fire protection system, the architect should follow the provisions of:

a. RA. No. 9514

b. B.P. BIg. 344

c. P.D. No. 1096

d. Follow both a and b

c. P.D. No. 1096

16
New cards

In SPP Document 204-A, the architect engaged only as Head of the Construction Supervision Group can make decisions with respect to design.

a. Absolutely True

b. Partially True

c. Absolutely False

d. Partially False

Absolutely False

17
New cards

The Construction Supervision Group (CSG) is responsible to the Owner only for administrative matters. For technical matters, the CSG is responsible to the Architect-of-record (Aor).

a. Both statements are False

b. Both statements are True

c. Only the first statement is True

d. Only the first statement is False

Both statements are True

18
New cards

The method of compensation for the Architect under SPP Document 205 is:

a. Percentage of Project Construction Cost

b. Per diem

c. Monthly salary

d. none of the above

Monthly Salary

19
New cards

According to SPP Document 209, the multiplier for the fee of a professional architectural consultant is

a. 2.00

b. 2.50

c. 3.00

d. 3.5

3.00

20
New cards

According to RA, 9514, what term is defined as any visual or audible signal produced by a device or system to warn the occupants of the building or fire fighting elements of the presence or danger of fire?

a. Fire Alerting System

b. Alarm

c. Fire Alarm

d. None of the above

Fire Alarm

21
New cards

According to RA. 9514 what's the mechanical device constant of linkages and horizontal bars , across a door which when pushed from the inside will cause the door to open and facilitate exit from the building, structure or locality?

a. Door closer

b. Fire Hardware

c. Panic door

d. Panic Hardware

Panic Hardware

22
New cards

According to RA 9514 what term is defined as a continuous and unobstructed route of exit from one point in a building, structure or locality to a public way?

a. Emergency Exit

b. Fire Exit

c. None of the above

d. Means of Egress

Means of Egress

23
New cards

According to R.A. 9514 what term is defined as the time duration that a material or construction can withstand the effect of a standard fire test?

a. Fire Resistance Rating

b. None of the above

c. Fire Test Evaluation

d. Fire Assessment Rating

Fire Resistance Rating

24
New cards

According to R.A, 9514, what term is defined as an integrated network of hydraulically designed piping systems installed in a building, structure or area with outlets arranged in a systematic pattern which automatically discharges water when activated by heat or combustion products from a fire?

a. Standpipe System

b. Sprinkler System

c. Automatic Fire System

d. None of the above

Sprinkler System

25
New cards

According to RA. 9514, what term is defined as the system of vertical pipes in a building to which fire hoses can be attached on each floor, Including a system by which water is made available to water outlets as needed?

a. Standpipe System

b. Sprinkler System

c. Automatic Fire System

d. None of the above

Standpipe System

26
New cards

According to RA. 9514, the minimum headroom shall not be less than _ m.

a. 2.00

b. 2.20

c. 2.70

d. 2.10

2

27
New cards

According to RA. 9514, the width of any means of egress shall not be less than _ mm. except when specifically provided

a. 1000

b. 900

c. 1200

d. 915

915

28
New cards

According to R.A. 9514, the max. height of risers for new stairs shall be _ mm.

a. 150

b. 200

c. 250

d. 180

180

29
New cards

According to RA. 9514, the max. height between landings for new stairs shall be _ mm.

a. 2700

b. 3500

c. 3000

d. 3660

3660

30
New cards

According to RA. 9514, the min. tread depth for new stairs shall be a _ mm.

a. 200

b. 280

c. 250

d. 300

280

31
New cards

According to RA. the min width for new stairs with less than 2000 persons shall be _mm.

a. 1120

b. 1200

c. 1250

d. 1500

1120

32
New cards

According to P.D. 1096, Traditional indigenous family dwellings shall be exempt from payment of building permit fees if the total cost of which does not exceed _.

a. ten thousand pesos (P10, 000.00)

b. twenty thousand pesos (P20,000.00)

c. thirty five thousand pesos (P35,000,00)

d. fifteen thousand pesos (P15.000.00)

fifteen thousand pesos (P15.000.00)

33
New cards

According to PD. 1096, what term is defined as a roofed or covered sidewalk?

a. Arcade

b. Awning

c. Abutment

d. Fire Wall

Arcade

34
New cards

According to P.D. 1096, what term is defined as the line formed by the intersection of the outer space of the enclosing wall of the building and the surface of the ground?

a. Building line

b. Property Line

c. Setback

d. Floor Area Ratio

Building Line

35
New cards

According to P.D. 1096, for perpendicular parking, what is the size of an average automobile parking?

a. 3.60m x 12.00m

b. 3.15m x 6.00m

c. 2.50m x 5.00m

d. 2.50m x 5.50m

2.50 x 5.00 m

36
New cards

According to P.D. 1096, for parallel parking, what is the size of an average automobile parking?

a. 3.60m x 12.00m

b. 2.15m x 6.00m

c. 2.50m x 5.00m

d. 2.50m x 5.50m

b. 2.15m x 6.00m

37
New cards

According to P.D, 1096, stairs for group A dwelling shall be at least _ m in clear width.

a. 0.75

b. 0.55

c. 0.50

d. 0.60

0.75

38
New cards

According to P.D. 1096, habitable rooms with artificial ventilation shall have a ceiling height of _.

a. 2.20m

b. 2.40m

c. 3.00m

d. 2.70m

2.40m

39
New cards

According to P.D. 1096, the mezzanine floor shall have a clear ceiling of not less than _ above and below it.

a. 1.50m

b. 1.90m

c. 1.30m

d. 1.80m

1.80m

40
New cards

According to P.D. 1096, habitable rooms with natural ventilation shall have a ceiling height of _.

a. 2.20m

b. 2.40m

c. 3.00m

d. 2.70m

2.70m

41
New cards

What is the minimum area of a room suitable for human habitation?

a. 4.0 sq. m.

b. 6.0 sq. m.

c. 3.0 sq. m.

d. 8.0 sq. m

6.0 sq. m

42
New cards

As per P.D, 1096. What percent of the floor area of the room intended for any use without artificial ventilation shall have a window or windows with openings equal to it?

a. 12%

b. 20%

c. 10%

d. 15%

10%

43
New cards

As per P.D. 1096, If the floor area of a room is 6 sq.m. What is the min. area of the window opening?

a. 0.60 sq.m.

b. 1.00 sq.m.

c. 1.20 sq.m.

d. 1.40 sq.m.

0.60 sqm

44
New cards

According to B.P. 344, accessible elevators should be located not more than _ from the entrance and should be easy to locate with the aid of signs.

a. 20.00m

b. 30.00m

c. 40.00m

d. 50.00m

30.00m

45
New cards

According to BP. 344, what is the term used when referring to features that enable disabled persons to make use of the primary functions for which a structure is built?

a. Accessible

b. Barrier free

c. Reachable

d. PWD Friendly

Accessible

46
New cards

Passing Score according to the Architecture Act of 2004

70%