Fire Code
Considers the building density in the locality and flammability of the structures and its contents
Elevated Water Tank
A traditional design of storing water in an elevated reservoir
Underground Water Reservoir
It is a reinforced concrete structure constructed on one side of the building provided with a small vent rising above the ground
60 to 90cm
The underground water reservoir is covered with earth from _____ blended with the lawn and lanscape shrubbery
Standby diesel powered generator
This unit and its fuel stock are seperately housed in a fire resistant enclosure sufficiently away from the possible location of fire in the main building
Up-Feed Pumping System
Provides a continuous flow of water from the deep wall through the domestic and fire reservoir.
20
A small ____ gallons per minute jockey pump will supply the necessary pressure for the sprinkler system
750
A signal from the sprinkler system will start the _____ gpm main pump
Diesel Engine Driven Pump
If the main pump becomes inadequate for the demand, ________ of equal capacity will automatically takes over.
Bubble Control Units
Senses domestic water level and sprinkler reserve level
Dual Control Unit
Regulates the supply for the pressure tank
Central Cabinet Underground Pump Room
The Sensing Unit controls are connected to a ______ adjacent the reservoir.
Hydropneumatic Tank
Used to store air under pressure that will balance out-surge from the two domestic pumps and reduce the frequently starting, and stopping of motor
60% to 40%
The dual control installation eliminates the need for manual adjustment of this ________ ratio by employing two sensing devices within a single control
Standpipe
A pipe installed in buildings not as part of the water supply or disposal system, but primary, for use as water conveyance in case of fire.
Fire Hose
Always located near the stairs for use by firemen in case of fire
Siamese Twin
Upon arrival of the firemen, the standpipe ______ is immediately connected to the street fire hydrant, or to any other source by their fire hose
15cm
Minimum Standpipe Height
Automatic Sprinkler System
Consists of horizontal pattern of pipes placed near the ceiling of industrial and commercial buildings, warehouses, stores, theaters and other structures where fire hazard require their use
135-160 degrees F
The automatic sprinkler system are provided with outlet and sprinkler heads that open automatically at temperatures of ________ and emit a series of fine water sprays
Wet Pipe Sprinkler System
The piping installations wherein both the mains and the distribution pipes are constantly filled with water
Dry Pipe Sprinkler System
The piping installations where there is no water standing in the distribution pipe, except during the occurence of fire. This is generally confined to unheated buildings.
Sprinkler Head
The bulb is quartzoid type. Transparent and contains a colored liquid.
136 degrees Fahrenheit
The Sprinkler bulb breaks and automatically releases a water stream
Pendant Sprinkler
Heat sensitive breakable bulb
Light Hazard Occupancy
The coverage of one sprinkler head is 20sq.m
Extra Hazard Condition
The coverage of one sprinkler head is 10sq.m
2.40 to 3.60m
Nozzles are set about _______ apart on the supply pipes
3.00 to 4.00m
Nozzles are set about ______ apart at right angle exposed beams or panels
1
At least one fire department connection on each frontage
Master alarm Valve
A _______ control for all water supplies other than fire department connections
Drains
Sloping water proof floors with ____ or scupper to carry away waste water.
25%
When gravity tank is used with sprinkler system, it must have enough water reserve for this purpose and enough water to operate at least _____ of the sprinklers for 30 mins
Automatic venting device
relieves the burning building of smoke and hot gases immediately. Undue delay will be avoided, and the firemen will not waste time chopping an opening for the exhaust of heat and smoke
Wet Standpipe and Siamese Connection
Connected to the water supply and distribution system. The disadvantage of this installation is when there is inadequate water supply for fire fighting.