What conditions allow for a system to be opened and repaired without recovering the refrigerant to the required vacuum level?

A system with a large leak and internal pressure of 0 psig

2
New cards

Refrigerant should be recovered from the condenser outlet if the condenser is;

Below the reciever

3
New cards

What can be done with a refrigerant trace gas and nitrogen mixture after a system leak is found?

Release into the atmosphere

4
New cards

Leaks must be repaired on industrial process and refrigeration units with a 50-pound charge or greater when the annualized leak rate reaches _____ or more.

30%

5
New cards

What must the equipment owners/operators include in recovered refrigerant records for equipment with refrigerant charges that range from 5 to 50 pounds?

The quantity of refrigerant (by type) added or recovered from disposed appliances in each calendar month and quantity of refrigerant (by type) sent for reclamation or destruction.

6
New cards

What happens to a refrigerant that is heated above the saturation temperature?

It remains in the vapor state

7
New cards

Unless plans are made to replace a system with a leak rate that exceeds the maximum leak rate, repairs must be made within;

30 Days

8
New cards

Which of the following refrigerants is classified as a very high-pressure refrigerant?

R-744

9
New cards

Proper recovery techniques begin with the use of appropriate recovery equipment that has been certified by;

EPA approved laboratory

10
New cards

A high-pressure appliance containing 210 lbs. of R-407C refrigerant must be evacuated (recovered) to a level of

10 Inches of Vaccum

11
New cards

A crankcase heater is often used to prevent refrigerant from mixing with compressor oil during periods of:

Low ambient temperature

12
New cards

All HVAC/R systems must be protected by a;

Pressure Relief Valve

13
New cards

A comfort cooling system that contains 50 pounds or more of R-410A is leaking. What will be the new maximum allowable annual leak rate starting in 2019?

10%

14
New cards

Refrigerants CFC-12, HCFC-22, and HFC-134a are all classified as Type _______ substances.

A-1

15
New cards

A high-pressure appliance containing less than 200 lbs. of an HCFC or HFC refrigerant must be evacuated (recovered) to a level of

0 inches of vacuum

16
New cards

EPA regulations require that all Industrial Process Refrigeration (IPR) systems containing more than 50 pounds of refrigerant MUST be repaired when the annual leak rate exceeds;

30%

17
New cards

When using a recovery unit on a system containing 100 lbs. of R-410A it must be evacuated to;

0 inches of mercury

18
New cards

A new split system should be checked for leaks by;

pressurizing the system with a few ounces of system refrigerant and an inert gas.

19
New cards

When an appliance containing 50 pounds or more of a regulated refrigerant leaks refrigerant at an annual rate of 125% or more, what must be included on the leak inspections records?

Initial verification, verification tests and records of recovered refrigerant from equipment.

20
New cards

A refrigerant sensor which will sound an alarm and automatically start a ventilation system in occupied equipment rooms falls under ASHRAE Standard;

15

21
New cards

EPA regulations state that removal of which component constitutes a "major repair"?

compressor

22
New cards

Non-condensables will cause;

High Discharge Pressure

23
New cards

When recovering refrigerant from a medium-pressure system with more than 200 lbs. of refrigerant, recover to a level of

15" Hg

24
New cards

If a leaking appliance with a regulated refrigerant is not going to be repaired, it must be;

retrofitted or retired within 12 months.

25
New cards

When dehydrating a system, it should be evacuated to a minimum level of;

500 microns