1
New cards

If the radiographer is unable to achieve a short object-image distance due to structure of the body part or patient condition, which one of the following adjustments may be made to minimize magnification?

longer source-image distance should be used

2
New cards

What is the single most important factor controlling size distortion?

OID

3
New cards

Spatial resolution is directly related to:

SID

4
New cards

Types of shape distortion include:

  1. foreshortening

  2. magnification

  3. elongation

1 and 3

5
New cards

Which one of the following sets of factors will produce the most magnification?

40 inch SID and a 4 inch OID

6
New cards

The line-focus principle expresses the relationship between:

the actual focal and effective focal spot

7
New cards

To get a magnification factor of 2, where should the object be placed?

halfway between the image receptor and x-ray tube

8
New cards

The effective focal spot is always larger than the actual focal spot.

false

9
New cards

If the SID is 40 inches and the OID is 6 inches, what is the magnification factor?

1.17

10
New cards

If an examination of the skull is to be taken using 400 mA, 1/8 second, 80 kVp, 36 inche SID, 4 inch OID, and if the object size is 8 inches, what will the image size be?

9 inches

11
New cards

As focal spot size increases, distortion would:

focal spot does not affect magnification

12
New cards

An object is radiographed utilizing a 40 inch SID and a 4 inch OID. What would be the resultant effect if the object is radiographed utilizing a 48 inch SID and an 8 inch OID?

increased magnification

13
New cards

Focal spots are represented in millimeters. Example 0.6, 0.9, 1.0, 1.2. Which focal do these numbers represent?

effective focal spot

14
New cards

An object is radiographed utilizing a 40 inch SID and a 4 inch OID. What would be the resultant effect if the object is radiographed utilizing a 44 inch SID and a 2 inch OID?

increased spatial resolution

15
New cards

Which of the following could be utilized to reduce geometric blur resulting from theuse of a large focal spot?

  1. increase kVP

  2. Increase OID

  3. Increase SID

3 only

16
New cards

Use of a perpendicular beam technique should be used whenever possible:

  1. decrease long scae contrast

  2. minimize elongation

  3. minimize shape distortion

2 and 3

17
New cards

A PA projection of the chest was produced with an SID of 72 inches and an OID of 8 inches. What is the MF?

1.12

18
New cards

On a PA chest image taken with an SID of 72 inches and an OID of 6 inches, the size of a round lesion in the left lung measures 2.6 inches in diameter on the radiographic image. What is the object size of this lesion?

2.38

19
New cards

When a focal spot is evaluated, the measurment for size (0.3, 0.6, 1.2 mm); which focal spot is actually being measured?

effective focal spot

20
New cards

Which one of the following would produce the best recorded detail?

72 inch SID, 4 inch OID, small focal spot

21
New cards

What does a line pair mean?

one black line and one white line

22
New cards

The area on the anode where the electrons hit is called the:

actual focal spot

23
New cards

The higher the spatial resolution, the better the recorded detail.

true

24
New cards

A radiograph is performed using 50 mAs, 80 kVp, 40 inch SID, and 16 inch OID and a 2 mm focal spot. The magnification factor for this image is approximately:

1.6

25
New cards

An object measuring 18 cm in length is radiographed at a 100 cm SID and a 10 cm OID. How long will the resulting radiographic image be?

20 cm

26
New cards

A condition caused by angling the xray tube against the main axis of the part is:

foreshortening

27
New cards

Of the following, which one of the following is MOST responsible for radiographic spatial resolution?

focal-spot size

28
New cards

An undistorted radiographic image will result when the object plane and the image receptor plane are:

parallel