A successful engineer needs to realize the importance of life-long learning and continuously update knowledge and job skills
True
To express contaminant concentrations in water, 1 ppm is equivalent to 1,000 mg/l
false
Removing carbon dioxide (CO2) in water will increase the pH of the water
true
Adding salts to a water sample will raise its boiling point
true
Coliform is commonly used as an indicator microorganism with regards to water quality
true
Our drinking water needs to be both potable and palatable
false
Saturated dissolved oxygen (DOsat) concentration in water open to air is ~30 mg/L @ 20 degrees celsius
false
The sulfate buffer system controls the pHs of our ambient rivers and lakes
false
The concentration inside a plug flow rector (PFR) is the same as the reactor effluent
false
Batch reactors are operated under unsteady state
true
Na2CO3 is the chemical formula for soda ash
true
Chloride ion (Cl-) is considered as part of the hardness in water
false
Coagulants are added to the coagulation process to destabilize the colloidal particles
true
Colloidal particles in our ambient water typically carry positive charges
false
For a coagulation/flocculation process, the velocity gradient of coagulation is larger than that of flocculation
true
For three reactors in parallel, the entire flow goes through all the three reactors
false
In a lime-soda softening process, carbonate hardness is harder to remove than non-carbonate hardness
false
In a lime-soda softening process, magnesium ions are harder to remove than calcium ions
true
In zone/hindered settling, particles will accelerate downward until reached a terminal velocity
false
The hydraulic loading rate can be used to determine the top surface area of a sedimentation tank
true
According to Schultz-Hardy rule, Al+3 is a more effective coagulant than Na+
true
For coagulation/flocculation, the velocity gradient of flocculation > that of coagulation
false
For coagulation/flocculation, typical hydraulic detention time for coagulation is about 20 minutes
false
In discrete particle settling, a particle will accelerate downward until reached its terminal velocity
true
Saturated dissolved oxygen (DOsat) concentration in water open to air is ~150 mg/L @ 20 degrees celsius
false
To express contaminant concentrations in water, 1ppm is equivalent to 1.0 g/L
false
Na2CO3 is the chemical formula for hydrated lime
false
Compared to CFSTRs, PFRs are a better type of reactors for chlorine contact tanks
true
The hydraulic loading rate is often used to determine the water depth of the process tank
false
____ tests are often used in bench-scale studies to determine optimal coagulant and dosage
jar
According to Stokes Law, the terminal velocity of a 30μ particle would be ___ times faster than that of a 10μ particle
nine
Alkalinity of water is its capacity to neutralize
acids
BOD5 values represents the amount of biodegradable ___ in water samples
organics
For water balance, precipitation = infiltration + evapotranspiration + storage + ____
runoff
For water quality, conductivity is an on-line indicator of ___ solid concentrations
dissolved
Give a commonly-used unit for power: ____
watts
Hydraulic detention of a process tank = ____ / Influent flow rate
volume
MCL = Maximum ____ Level
Contaminant
pH + pOH = ___ at 20 degrees celsius
14
SDWA = ____ Drinking Water Act (Note: it is a federal regulation for drinking water)
Safe
The oxidation state of sulfur in sulfate (SO4-) equals to
+6
TSS = FSS + ____
VSS
Two sources of water for drinking water supply: surface water and ____
groundwater
Weight density of water = 9.81 kN/m^3 = ____ lb/ft^3 at 4 degrees celcius
62.4
A water treatment plant contains filtration, flocculation, coagulation, and sedimentation (put thesefour unit processes/operation in a right order)
coagulation, flocculation, sedimentation, filtration
Groundwater and surface water are two main sources for potable water supply.
True
More constant water composition - groundwater or surface water?
Ground water
Higher dissolved oxygen concentration - groundwater or surface water?
Surface water
Higher pathogen concentration - groundwater or surface water?
surface water
TDS = VDS +
FDS
For water quality, turbidity is an on-line indicator of ___ solid concentrations
suspended
The oxidation state of carbon in carbonate ions (CO3= ) equals to ___
+4
After lime and soda softening, the magnesium concentration in water should be kept below ___ mg/L to prevent formation of hard scale.
40
According to Stokes Law, the terminal velocity of a 10-μ particle would be ___ times faster than that of a 2-μ particle of the same type
25
VSS+FSS=
TSS
TDS+TSS=
TS