1/71
Looks like no tags are added yet.
Name | Mastery | Learn | Test | Matching | Spaced |
---|
No study sessions yet.
RROW WIDTH
BELOW 10M
REQ SIDEWALK WIDTH?
WIDTH OF PLANTING STRIP?
REQ SW: FROM 1/4 TO 1/3 OF RROW WIDTH
MIN. WIDTH OF PS: OPTIONAL
RROW WIDTH
10-19M
REQ SIDEWALK WIDTH?
WIDTH OF PLANTING STRIP?
REQ SW: FROM 1/4 TO 1/3 OF RROW WIDTH
MIN. WIDTH OF PS: 0.40M
RROW WIDTH
20-24M
REQ SIDEWALK WIDTH?
WIDTH OF PLANTING STRIP?
REQ SW: FROM 1/6 TO 1/3 OF RROW WIDTH
MIN. WIDTH OF PS: 0.60M
RROW WIDTH
25-29M
REQ SIDEWALK WIDTH?
WIDTH OF PLANTING STRIP?
REQ SW: FROM 1/6 TO 1/3 OF RROW WIDTH
MIN. WIDTH OF PS: 0.60M
RROW WIDTH
30M AND ABOVE
REQ SIDEWALK WIDTH?
WIDTH OF PLANTING STRIP?
REQ SW: FROM 1/6 TO 1/4 OF RROW WIDTH
MIN. WIDTH OF PS: 1.20M
WIDTH OF RROW SHALL BE MEASURED FROM?
EDGE OF SIDEWALK TO PLANTING STRIP
THE SIDEWALK PAVEMENT SHALL HAVE A NON SLIP SURFACE AND SHALL SLOPE DOWN FROM THE BLDNG LINE TOWARDS THE CURB LINE AT NO MORE THAN ___ AND SHALL LEVEL OFF WITH THE CURB
1/50
SIDEWALKS OF 2M OR MORE IN WIDTH SHALL INCLUDE ON ITS OUTER SIDE A PLANTING STRIP OF NOT LESS THAN ____ SEPARATING THE CURB FROM THE SIDEWALK PAVEMENT
800MM
CEILING HEIGHTS
HABITABLE ROOMS PROVIDED W ARTIFICAL VENTILATION SHALL HAVE A CEILING HT OF NOT LESS THAN ___M MEASURED FROM FLOOR TO CEILING
2.40M
CEILING HEIGHTS
FOR BUILDINGS WITH MORE THAN 1 STOREY, THE MIN FLOOR TO FLOOR HEIGHT FOR THE GF IS
2.7M
CEILING HEIGHTS
MEZZANINE FLOORS SHALL HAVE A MIN CLEAR CEILING HEIGHT OF
1.8M
WINDOWS
ALL ROOMS WITHOUT MECHANICAL VENTILATION SHALL BE PROVIDED W WINDOWS W A TOTAL FREE AREA OF OPENINGS EQUAL TO OR AT LEAST ___ OF THE FLOOR AREA OF THE ROOM
10%
TOILETS AND LAUNDRY ROOMS MAY BE PROVIDED WITH WINDOWS WITH A TOTAL FREE AREA OF OPENINGS EQUAL TO OR AT LEAST ___ OF THE FLOOR AREA OF THE ROOM
5%
ABSOLUTELY NO OPENIGNS ARE ALLOWED ALONG ?
PROPERTY LINES
WINDOWS TO BE USED FOR EMERGECY EGRESS SHALL HAVE A MIN WIDTH OF ___ AND A HEIGHT OF __. THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 820 MM FROM THE FLOOR
WIDTH - 820 MM
HEIGHT - 1000MM
VENT SHAFTS SHALL HAVE A MIN CROSS SECTIONAL AREA OF 1 SQM. NO VENT SHAFT SHALL HAVE ITS LEAST DIMENSION LESS THAN ___
600MM
DRAINAGE GENERAL PROVISIONS
HORIZONTAL DRAINAGE PIPES SHALL HAVE A MINIMUM SLOPE OF ___ TOWARDS THE POINT OF DISPOSAL
HOWEVER, ANY PIPE 102 MM OR LARGER IN DIAMETER MAY HAVE A SLOPE OF NO LESS THAN __
2%
1%
MIN SLOPE FOR FLAT ROOF IS?
2%
RECCOMMENDED ROOF PITCH
15-30 DEG
RECCOMMENDED SLOPE FOR SHOWER FLOORS
2-4%
ALL SHOWER AREAS SHOULD HAVE A THRESHOLD OF AT LEAST ___ MM LOWER THAN THE OUTSIDE FLOOR. THRESHOLD SHALL BE ABLE TO ACCOMMODATE A MIN OF ___MM WIDE DOOR
25.4MM, 599 MM
ALL SHOWER AREAS MUST BE ABLE TO ACCOMMODATE A ____MM DIAMETER CIRCLE
762
PROTECTIVE ENCLOSURE OF EXITS
SEPARATION SHALL HAVE AT LEAST 1 HR FIRE RESISTANCE RATING WHEN EXIT CONNECTS __ STOREYS OR LESS
3
PROTECTIVE ENCLOSURE OF EXITS
SEPARATION SHALL HAVE AT LEAST 2 HR FIRE RESISTANCE RATING WHEN EXIT CONNECTS __ STOREYS
4 OR MORE
ANY OPENING IN THE SEPARATION WALL SHALL BE PROTECTED BY AN _____ FIRE RESISTING DOOR
APPROVED SELF CLOSING
MEASUREMENT OF MEANS OF EGRESS
THE WIDTH OF MEANS OF EGRESS SHALL BE MEASURED BY CLEAR WIDTH STARTING FROM THE ___ POINT
NARROWEST
MEASUREMENT OF MEANS OF EGRESS
PROJECTIONS OF NOT MORE THAN ___MM AT A MAX HEIGHT OF 965MM WITHIN THE MEANS OF EGRESS ON EACH SIDE SHALL BE
114MM
ANY MEANS OF EGRESS SHALL NOT BE LESS THAN ___MM WIDE
915
THE NUMBER OF MEANS OF EGRESS FROM ANY STOREY INCLUDING MEZZANINES SHALL NOT BE LESS THAN
2
WHEN THE OCCUPANT LOAD FOR ANY STOREY OR PORTION THEREOF IS MROE THAN 500 BUT LESS THAN 1000, THE MEANS OF EGRESS SHALL BE
3
IN EXCESS OF 1000 OCCUPANT LOAD, THE MEANS OF EGRESS SHALL BE
4
MINIMUM NUMBER OF EXITS
GENERAL REQUIREMENTS
<500 OCCUPANT LOAD
AT LEAST 2 EXITS
MINIMUM NUMBER OF EXITS
GENERAL REQUIREMENTS
500-1000
AT LEAST 3 EXITS
MINIMUM NUMBER OF EXITS
GENERAL REQUIREMENTS
>1000 OCCUPANT LOAD
AT LEAST 4 EXITS
MINIMUM NUMBER OF EXITS
GENERAL REQUIREMENTS
ASSEMBLY
MAIN EXIT WHICH ACCOMMODATES 1/2 OF THE TOTAL OCCUPANT LOAD AND SHALL CONNECT TO A STAIRWAY OR RAMP LEADING TO A STREET
MINIMUM NUMBER OF EXITS
GENERAL REQUIREMENTS
EDUCATIONAL
EVERY ROOM W A CAPACITY OF 50 OR MORE OR OVER 93 SQM SHALL HAVE AT LEAST 2 DOORWAYS REMOTE FROM EACH OTHER
NO LESS THAN 2 SEPARATE EXITS ON EVERY FLOOR/MEZZANINE
MINIMUM NUMBER OF EXITS
GENERAL REQUIREMENTS
HEALTH CARE
ON ALL LEVELS: AT LEAST 2 EXITS
ELEVATORS DO NOT COUNT AS REQUIRED EXITS
MINIMUM NUMBER OF EXITS
GENERAL REQUIREMENTS
DETENTION, RESIDENTIAL, BUSINESS
ON ALL LEVELS: AT LEAST 2 EXITS
SINGLE MEANS OF EGRESS IS ALLOWED FOR MEZZANINE FLOORS PROVIDED THAT THE TRAVEL DISTANCE IS NOT LESS THAN 30M
AT LEAST 1.5 OF THE REQ EXITS SHALL BE REACHED WITHOUT GOING THROUGH CHECK OUT STANDS
A SINGLE EXIT IS PERMITTED FOR A ROOM WITH LESS THAN 100 PERSONS PROVIDED IT EXITS DIRECTLY TO THE OUTSIDE AT THE LEVEL OF DISCHARGE
MINIMUM NUMBER OF EXITS
GENERAL REQUIREMENTS
MERCANTILE
SINGLE MEANS OF EGRESS IS ALLOWED FOR STORES WITH A GFA LESS THAN 278 SQM PROVIDED THAT THE TRAVEL DISTANCE IS NOT LESS THAN 23M
MINIMUM NUMBER OF EXITS
GENERAL REQUIREMENTS
STORAGE
ON ALL LEVELS: 2 EXITS
SINGLE MEANS OF EGRESS IS ALLOWED FOR STORAGE ROOMS OR AREAS WITH GFA LESS THAN 1,394 SQM WHERE LESS THAN 10 PEOPLE ARE NORMALLY PRESENT
MINIMUM NUMBER OF EXITS
GENERAL REQUIREMENTS
PARKING
EVERY FLOOR SHALL HAVE AT LEAST 2 EXITS TRAVELLING AWAY FROM THE FUEL PUMPS IF LOCATED ON A PARKING FLOOR
TRAVEL DISTANCE TO AN EXIT
IN CASE OF INDIV ROOMS SUBJECT TO OCCUPANCY BY NOT MORE THAN 6 PEROSNS, TRAVEL FROM ANY POINT IN THE ROOM TO THE ROOM DOOR DOES NOT EXCEED ___
15M
WHERE OPEN STAIRWAYS OR RAMPS WERE USED AS A PATH OF TRAVEL TO REQUIRED EXIT (MEZZ OR BALC) , DISTANCE SHALL INCLUDE THE TRABEL ON THE ___
STAIRWAY OR RAMP
IN THE CASE OF OPEN AREAS, DISTANCE TO EXITS SHALL BE MEASURED FROM THE MOST___ POINT SUBJECT TO OCCUPANCY
REMOTE
FOR NON PRESSURIZED AND NON SPRNKLERED EXITS, TRAVEL DISTANCE SHALL INCLUDE THE ___
RAMP OR STAIR
TRAVEL DISTANCE IS MEASURED FROM ____ OF NATURAL PATH OF TRAVEL STARTING FROM MOST REMOTE POINT TO DOORWAY OR TREAD NOSING
CENTERLINE
DIRECT EXIT/FIRE EXIT STAIRS GENERAL PROVISIONS
MIN HEADROOM
2M
DIRECT EXIT/FIRE EXIT STAIRS GENERAL PROVISIONS
RE ENTRY MECHANISM EVERY?
4 FLOORS
DIRECT EXIT/FIRE EXIT STAIRS GENERAL PROVISIONS
MIN SIZE OF DOOR IS ___, MAX SIZE IS____
.71M, 1.22M
DIRECT EXIT/FIRE EXIT STAIRS GENERAL PROVISIONS
STAIR MIN RUN?
280 MM
DIRECT EXIT/FIRE EXIT STAIRS GENERAL PROVISIONS
STAIR MAX RISE?
180 MM
DIRECT EXIT/FIRE EXIT STAIRS GENERAL PROVISIONS
STAIR MIN RISE?
100 MM
DIRECT EXIT/FIRE EXIT STAIRS GENERAL PROVISIONS
LANDING DIMENSION IN THIS DIRECTION OF TRAVEL SHOULD NOT BE LESS THAN THE
STAIR WIDTH
DIRECT EXIT/FIRE EXIT STAIRS GENERAL PROVISIONS
<50 PERSONS __ WIDTH
915 MM
DIRECT EXIT/FIRE EXIT STAIRS GENERAL PROVISIONS
<200 PERSON ___ WIDTH
1120 MM
DIRECT EXIT/FIRE EXIT STAIRS GENERAL PROVISIONS
>2000 PERSON ___ WIDTH
1420 MM
DIRECT EXIT/FIRE EXIT STAIRS GENERAL PROVISIONS
HANDRAIL HEIGHT ?
IT IS MEASURED 25MM BACK FROM THE LEADING EDGE. IF DESIGNED FOR CHILDREN, AN ADDITIONAL HANDRAIL LOWER THAN THE MAIN SHALL BE PROVIDED
76 - 86.5 MM
MIN CORRIDOR WIDTH -- SHALL APPLY TO ALL CORRIDORS LEADING TO EXITS
ASSEMBLY
1120 MM
MIN CORRIDOR WIDTH -- SHALL APPLY TO ALL CORRIDORS LEADING TO EXITS
EDUCATIONAL;
1830MM
MIN CORRIDOR WIDTH -- SHALL APPLY TO ALL CORRIDORS LEADING TO EXITS
HEALTH CARE
2440 MM
MIN CORRIDOR WIDTH -- SHALL APPLY TO ALL CORRIDORS LEADING TO EXITS
DETENTION
1120 MM
MIN CORRIDOR WIDTH -- SHALL APPLY TO ALL CORRIDORS LEADING TO EXITS
RESIDENTIAL
1120 MM
MIN CORRIDOR WIDTH -- SHALL APPLY TO ALL CORRIDORS LEADING TO EXITS
MERCANTILE
1500 MM
MIN CORRIDOR WIDTH -- SHALL APPLY TO ALL CORRIDORS LEADING TO EXITS
BUSINESS
1120 MM
MIN CORRIDOR WIDTH -- SHALL APPLY TO ALL CORRIDORS LEADING TO EXITS
INDUSTRIAL
1120 MMM
HORIZONTAL EXITS GENERAL PROVISIONS
EXT WAY OF EXIT MAX DEAD END IS ___
6M
MIN CORRIDOR WIDTH -- SHALL APPLY TO ALL CORRIDORS LEADING TO EXITS
___% OF OCCUPANTS SHALL EXIT THROUGH OPEN AREAS LESS THAN ___ M AWAY
50%, 6M
MIN CORRIDOR WIDTH -- SHALL APPLY TO ALL CORRIDORS LEADING TO EXITS
REVOLVING DOOR = ___% OF DOOR WIDTH CAPACITY
50
MIN CORRIDOR WIDTH -- SHALL APPLY TO ALL CORRIDORS LEADING TO EXITS
TURNSTILES SHOULD BE AT LEAST __M WIDE
.91 M
WALL FIRE RATINGS
1 HR FIRE RATED WALLS REQUIIRED
STORAGE
LAUNDRY
KITHENS
WASTE COLLECTION
LINEN COLLECTION
FIRE EXIT STAIRS AND VESTIBULES FOR BLDNGS 3 STOREYS OR MORE
CHUTE ACCESS RM
BOILER RM
PAINT SHOP
REFRIGERATION MACHINE RM
HOTEL AND OFFICE CORRRIDOR
ELEV LOBBY
WALLS THAT DIVIDE OCCUPANCIES IN BLDNG
EXT WALLS THAT HAS POTENTIAL TO BE EXPOSED TO MODERATE FIRE FROM OUTISDE
WALL FIRE RATINGS
2 HR FIRE RATED WALLS REQUIRED
CHUTE TERMINATION RMS
EMERGENCY ELECTRICAL EQUIPMENT RM
FIRE PUMP RM
PARKING GARAGE
FIRE EXIT STAIRS AND VESTIGBULE FOR BUILDINGS 4 STOREYS OR MORE
EXT WALLS
FLOOR SLAB
ROOF
ELEV SHAFTS
MEPF SHAFTS
STAIRWELLS
WALLS THAT SEPARATE BLDNGS OR DIVIDE A SINGLE BLDNG INTO A DESIGNATED FIRE AREA SHALL BE ___ HRS FIRE RATED WITH ___MIN DOOR FIRE RATING
4 HRS, 180MIN