AIR removal system

0.0(0)
studied byStudied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/10

encourage image

There's no tags or description

Looks like no tags are added yet.

Last updated 5:48 PM on 2/24/25
Name
Mastery
Learn
Test
Matching
Spaced
Call with Kai

No analytics yet

Send a link to your students to track their progress

11 Terms

1
New cards

what is the purpose of the AR system

establish vacuum on startup and remove non condensable gasses at power

2
New cards

where does the system normally discharge to?

how is it monitored

the plant vent stack, By and RU monitor

3
New cards

how many stages are the AR pumps

2 stages

4
New cards

what are the auto starts for AR pump D

4.2 Hga in A shell

4.8 Hga in B shell

5.3 Hga in C shell

5
New cards

What are the auto actions of the D ar pump suction vavle

Will auto open to the shell with degraded vacuum if more than one has a degraded vacuum it will open to all affected shells

6
New cards

describe the AOV valves 19A 19B and 13

19 A is the inlet to the filter 19 B is the bypass valve and 13 is the outlet valve

7
New cards

what is the fail position for 19A, 19 B and 13

fails thru filter on loss of power or air

19a and 13 open

19B closed

8
New cards

what happens on an RU 141 alarm HI signal?

what is the hi RU 141 alarm indicative of?

turns on filter blower and aligns thru filter mode. the hi alarm is an early indication of SGTR

9
New cards

what provides makeup seal water to the AR pumps

makeup seal water is provided by the Condensate system

10
New cards

What cools the AR pumps

PW

11
New cards

what must be in service prior to starting the AR system

gland seal steam should be in service

Explore top flashcards