Continuous vent
A vertical vent that is a continuation of the drain to which it connects
Storm water drainage piping
A piping system designed to control and convey excess ground water to a suitable location
Private sewage disposal system
When no public sewer intended to serve any lot or premises is available in any thoroughfare or right of way abutting such a lot of premises, drainage piping from the building shall be connected to ___________________.
Fixture unit
A unit which is equivalent to the flow rate of one (1) cubic foot of water per minute or 7-1/2 gpm of water is _______________.
Watertight
Roof joint shall be ______________.
Lavatory
A fixture designed for the washing of hands or face, sometimes called wash basin
Excessive water pressure
A condition in the distribution system where it could damage or create condition that will damage components of the distribution system or create a nuisance is termed as ________________.
Vertical main soil, waste or vent piping
A stack as defined in the code
Back pressure
Air pressure in drainage pipes greater than the atmospheric pressure
Health officer
No clevical toilet shall be installed in any building unless first approved by the __________________.
Plumbing system
All water supply, drainage, venting system and all fixtures and their traps complete with their connection
3/8"
The minimum diameter size of water supply pipe to lavatory
72 hours
Request for inspection by the master plumber to the administrative authority is required to be made in advance at least before the work to be tested
Air gap
The vertical distance that waste travels through open air between the waste pipe and the indirect waste receptor
Branch interval
A means of measurement for vertical waste or soil stack. It is equal to each floor level or storey in a building but are always eight-feet intervals
Continuous waste
A drain connecting the compartments of a certain fixture to its trap is called ________________.
Storm water
Rain water is _______________.
Bushing
A pipe fitting used to reduce the size of an opening is called ___________.
8psi
The minimum pressure that should be maintained for fixtures containing flush tank supplies
Gutter
A piece of chemical fitted under another piece of flat metal or wood over which water is expected to run
10'
Supports anchorage of piping shall not exceed an interval of _____.
Fittings and adapters
When connecting plastic pipe to other types of piping, the specific transition intended shall be made with approved ____________________.
Rough piping inspection
The inspection of a gas piping system prior to covering or concealing such pipe is called a ____________________.
Copper tube with brazed joints
Copper tubing used for water piping under concrete slabs within a building shall be ___________________.
63psi
The static water pressure at the water meter is 80psi. At the outlet 40ft above the meter, the static water pressure would be approximately ________.
10 gal/min
The water demand for shower head is _____________ per day.
6"
Vent pipes may offset horizontally when the distance above the extreme overflow level of the fixture is at least ______.
5.00
The minimum plumbing permit charge for one unit is _______.
Storm sewer
A drainage pipe used to carry main of surface water, cooling water and similar liquid waste
Vents
Expansion joints shall be acceptable except in piping for __________.
Fixture
A receptacle attached to the plumbing system other than the trap in which waste may be collected or retained for an ultimate discharge into the plumbing system
5'
Cast iron piping in 10' lengths installed horizontally shall be supported at intervals of not more than _____.
Total fixture units
Sizes of vertical and horizontal drainage pipes shall be determined from _______________________.
Laminar flow
The valve for controlling which has gradual and regular variation over time and space is called __________________.
Rising stem gate valve
The valve for controlling two or more outlet in a cold water supply line may be a ___________________.
3/4"
The minimum size building supply by the code for water
ASTM
According to existing Plumbing Code, cast iron pipes, wrought iron pipes, weld steel pipes, copper pipes, vitrified clay, concrete and asbestos pipes shall conform to the standard other than the Philippine standard.
Aluminum
A material not listed in the code for use in water piping
Testing laboratory
The critical level marking or a backflow prevention device or vacuum breaker is a point established by the ____________________.
Within the building
cPVC water pipe may be used for hot and cold water distribution systems
Wye combination
When connecting horizontal drain line with another horizontal drain line, the acceptable fitting to be used is _______________________.
3"
The minimum allowable size of any building drain, horizontal branch, vertical soil or waste stack serving one or more water closets shall be _______.
Gutter
It is a box-like collection device which is located on the exterior of the building and receives storm water on one side
15psi for 15 min
The air pressure test for any threaded (low pressure) gas piping shall be at least _________________.
Cast iron
Caulked or screwed joints shall be applicable to _____________.
2"
The vent pipe serving a combination waste and vent system with a 4" drainpipe shall be at least _____.
Lowest to the highest point
Building sewers shall be tested by completely filling the sewer with water from the _______________________.
Exposed fixture supply
In the water supply piping slip joints may be used only on the ______________________.
Pressure relief valve
A water system containing a water heater will require ____________________.
Building sewer
The drainage pipe running from outside a building foundation to the main sewer
Plumbing code
A set of regulation adapted by an administrative agency that has jurisdiction over materials and design specification in plumbing
8%
The maximum lead content allowed in pipe used to convey potable water
Building drain
The lowest piping system that receives the discharge from soil waste and other drainage pipe
No
Is it permissible to place building sewer and drainage piping in the same trench with the water service pipe?
One year
Upon issuance of plumbing permit, plumbing installation shall commence within _______________.
Ball cock
An automatic fill device, most commonly found in toilet tanks
Soil pipe
A vertical pipe to convey main waste
DWV system
He drainage system is subdivided into three different components, drainage, the waste and the vent. This is referred to as
House sewer
The part of the plumbing system extending from a point 4 or 5 feet from the inner face of the foundation wall of a building to the junction with another sewer
Regulating equipment
Equipment which includes all valves and controls used in plumbing system are required to be accessible or readily accessible
26 GA
Rain water piping located on the exterior of a building using galvanized sheet metal shall not be less than ___________.
Insanitary
A term used which is contrary to sanitary principles or injurious to health
Ejector
An electricity or mechanically operated device used to elevated sewage and liquid waste from a lower level to a point of discharge into a sewer or other disposal system
4
The maximum fixture units loading allowed on a 2" waste stack
Septic tank
A watertight receptacle that receives sewage
Velocity
The force required to move the water inside the pipe
Bedpan washer
Another name for a clinical sink
Reynolds number
A measure of inertia forces to viscous forces, which sometimes describe whether it is turbulent or laminar flow is
Air gap device
A device used to connect drainage of a dishwasher with the sanitary drainage system is called
Vertical
A pipe which makes an angle of 45 degrees from the vertical is considered?
2 gallons
The minimum quantity of water for flushing urinal
Bending equipment
Changes in direction at copper tubing may be made with
House drain
That part of the lowest horizontal piping of the plumbing which receives the discharge from soil, waste and other drainage pipes inside of the building and conveys it to the house sewer
Cast iron
Piping which shall not be installed under of within 2' at any building or structure
Flanges
Fixtures connections between drainage pipes and water closets shall be made with ____________.
Cast iron bell and spigot soil pipe
A joint made by firmly packing with oakum and filled with molten lead to a depth of not less than 1 inch, is for what pipe?
12"
The distance between a water heater and the union on the water lines shall not be more than _____.
Control valve
What valve is required ahead of each water supplied appliance, each slip joints or non-metallic connection?
Vertical pipe
When pipe makes an angle of not more than 45 degrees with the vertical, it is considered as
4
Total number of water closets on a 3-inch stack
Diameter of the draw pipe served
A vent in a combination waste and vent system shall be approximately equal in area to one half _________________.
Drainage, waste and vent
DWV materials mean
48"
Every passage way to attic water heater shall have a solid continuous flooring not less than _____ wide.
Public or private sewer
Every building in which plumbing fixtures are installed shall have a connection to a
15psi
Allowing for friction and other pressure losses the available water pressure for fixture is
4
Th maximum trap loading for a 2" trap is ____ units.
Infiltration
The movement of water through the surface of a soil and into the soil below the surface is
1/4" per foot
The minimum slope of 3" horizontal pipe shall be not less than
Inlet connection of the appliance
The size of the supple piping outlet for any gas appliance shall not be less than the
Fixture unit
The quantity of water required to be supplied to every plumbing fixture shall be represented by
Sump
A pit or receptacle at a low point to which the liquid wastes are drained
10 ft head
The waste test for drainage system shall be at least
150%
_______ of used water pressure is required to test water supply system
5
Fee for one unit of plumbing as plumbing unit is
3-1/2"
The minimum size clean out allowed to serve a 4" drain line
Inside storm drain
A storm drain sometimes located under the basement floor within the walls of the
uPVC
Unplasticized polyvinyl chloride
UL
Underwriter's Laboratories
IAPMO
International Association of the Plumbing and Mechanical Officials
CCIP
Centrifugal Cast Iron Pipe