UPC MAXIMUM UNIT LOADING AND MAXIMUM LENGTH OF DRINAGE VENT PIPING

0.0(0)
studied byStudied by 0 people
0.0(0)
full-widthCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/52

encourage image

There's no tags or description

Looks like no tags are added yet.

Study Analytics
Name
Mastery
Learn
Test
Matching
Spaced

No study sessions yet.

53 Terms

1
New cards

1-1/4 Maximum Unit Drainage Piping, Vertical

1

2
New cards

1-1/4 Maximum Unit Drainage Piping, Horizontal

1

3
New cards

1-1/2 Maximum Unit Drainage Piping, Vertical

2

4
New cards

1-1/2 Maximum Unit Drainage Piping, Horizontal

1

5
New cards

2 Maximum Unit Drainage Piping, Vertical

16

6
New cards

2 Maximum Unit Drainage Piping, Horizontal

8

7
New cards

3 Maximum Unit Drainage Piping, Vertical

48

8
New cards

3 Maximum Unit Drainage Piping, Horizontal

35

9
New cards

4 Maximum Unit Drainage Piping, Vertical

256

10
New cards

4 Maximum Unit Drainage Piping, Horizontal

216

11
New cards

5 Maximum Unit Drainage Piping, Vertical

600

12
New cards

5 Maximum Unit Drainage Piping, Horizontal

428

13
New cards

6 Maximum Unit Drainage Piping, Vertical

1380

14
New cards

6 Maximum Unit Drainage Piping, Horizontal

720

15
New cards

8 Maximum Unit Drainage Piping, Vertical

3600

16
New cards

8 Maximum Unit Drainage Piping, Horizontal

2640

17
New cards

10 Maximum Unit Drainage Piping, Vertical

5600

18
New cards

10 Maximum Unit Drainage Piping, Horizontal

4680

19
New cards

12 Maximum Unit Drainage Piping, Vertical

8400

20
New cards

12 Maximum Unit Drainage Piping, Horizontal

8200

21
New cards

I inch

25 mm

22
New cards

I foot

304.8 mm

23
New cards

Footnote 1

Excluding trap arm

24
New cards

Footnote 2

Except for sinks, urinals, and dishwashers - exceeding 1 fixture unit.

25
New cards

Footnote 3

Except for six-unit traps or water closers.

26
New cards

Footnote 4

Only four water closets or six-unit traps allowed on a vertical pipe or stack, and not to exceed three water closets or six-unit traps on a horizontal branch or drain

27
New cards

Footnote 5

Based on 14 inch per foot (20.8 mm/m) slope. For i of an inch per foot (10.4 mmim) slope, multiply horizontal fixture units by a factor of 0.8.

28
New cards

Footnote 6

The diameter of an individual vent shall be not less than 14inches (32 mi) nor less than one-half the diameter of the drain to which it is connected. Fixture unit load values for drainage and vent piping shall be computed from Table 702.1 and Table 702.2(2) Not to exceed one-third of the total permitted length of a vent shall be permitted to be installed in a horizontal position Where vents are increased one pipe size for their entire length, the maximum length limitations specified in this table do not apply. This table is in accordance with the requirements of Section 901.3.

29
New cards

Horizontal Piping Length is

(unlimited)

30
New cards

1-1/4 Maximum Length Drainage Piping Vertical, (feet)

45

31
New cards

1-1/2 Maximum Length Drainage Piping Vertical, (feet)

65

32
New cards

2 Maximum Length Drainage Piping Vertical, (feet)

85

33
New cards

3 Maximum Length Drainage Piping Vertical, (feet)

212

34
New cards

4 Maximum Length Drainage Piping Vertical, (feet)

300

35
New cards

5 Maximum Length Drainage Piping Vertical, (feet)

390

36
New cards

6 Maximum Length Drainage Piping Vertical, (feet)

510

37
New cards

8 Maximum Length Drainage Piping Vertical, (feet)

750

38
New cards

1-1/4 Vent Piping Horizontal and Vertical, Maximum Units

1

39
New cards

1-1/2, Vent Piping Horizontal and Vertical, Maximum Units

8

40
New cards

2 Vent Piping Horizontal and Vertical, Maximum Units

24

41
New cards

3 Vent Piping Horizontal and Vertical, Maximum Units

84

42
New cards

4 Vent Piping Horizontal and Vertical, Maximum Units

256

43
New cards

5 Vent Piping Horizontal and Vertical, Maximum Units

600

44
New cards

6 Vent Piping Horizontal and Vertical, Maximum Units

1380

45
New cards

8 Vent Piping Horizontal and Vertical, Maximum Units

3600

46
New cards

1-1/4 Vent Piping Horizontal and Vertical, Maximum Lengths, (feet)

41

47
New cards

1-1/2, Vent Piping Horizontal and Vertical, Maximum Lengths, (feet)

60

48
New cards

2 Vent Piping Horizontal and Vertical, Maximum Lengths, (feet)

120

49
New cards

3 Vent Piping Horizontal and Vertical, Maximum Lengths, (feet)

212

50
New cards

4 Vent Piping Horizontal and Vertical, Maximum Lengths, (feet)

300

51
New cards

5 Vent Piping Horizontal and Vertical, Maximum Lengths, (feet)

390

52
New cards

6 Vent Piping Horizontal and Vertical, Maximum Lengths, (feet)

510

53
New cards

8 Vent Piping Horizontal and Vertical, Maximum Lengths, (feet)

750