1-1/4 Maximum Unit Drainage Piping, Vertical
1
1-1/4 Maximum Unit Drainage Piping, Horizontal
1
1-1/2 Maximum Unit Drainage Piping, Vertical
2
1-1/2 Maximum Unit Drainage Piping, Horizontal
1
2 Maximum Unit Drainage Piping, Vertical
16
2 Maximum Unit Drainage Piping, Horizontal
8
3 Maximum Unit Drainage Piping, Vertical
48
3 Maximum Unit Drainage Piping, Horizontal
35
4 Maximum Unit Drainage Piping, Vertical
256
4 Maximum Unit Drainage Piping, Horizontal
216
5 Maximum Unit Drainage Piping, Vertical
600
5 Maximum Unit Drainage Piping, Horizontal
428
6 Maximum Unit Drainage Piping, Vertical
1380
6 Maximum Unit Drainage Piping, Horizontal
720
8 Maximum Unit Drainage Piping, Vertical
3600
8 Maximum Unit Drainage Piping, Horizontal
2640
10 Maximum Unit Drainage Piping, Vertical
5600
10 Maximum Unit Drainage Piping, Horizontal
4680
12 Maximum Unit Drainage Piping, Vertical
8400
12 Maximum Unit Drainage Piping, Horizontal
8200
I inch
25 mm
I foot
304.8 mm
Footnote 1
Excluding trap arm
Footnote 2
Except for sinks, urinals, and dishwashers - exceeding 1 fixture unit.
Footnote 3
Except for six-unit traps or water closers.
Footnote 4
Only four water closets or six-unit traps allowed on a vertical pipe or stack, and not to exceed three water closets or six-unit traps on a horizontal branch or drain
Footnote 5
Based on 14 inch per foot (20.8 mm/m) slope. For i of an inch per foot (10.4 mmim) slope, multiply horizontal fixture units by a factor of 0.8.
Footnote 6
The diameter of an individual vent shall be not less than 14inches (32 mi) nor less than one-half the diameter of the drain to which it is connected. Fixture unit load values for drainage and vent piping shall be computed from Table 702.1 and Table 702.2(2) Not to exceed one-third of the total permitted length of a vent shall be permitted to be installed in a horizontal position Where vents are increased one pipe size for their entire length, the maximum length limitations specified in this table do not apply. This table is in accordance with the requirements of Section 901.3.
Horizontal Piping Length is
(unlimited)
1-1/4 Maximum Length Drainage Piping Vertical, (feet)
45
1-1/2 Maximum Length Drainage Piping Vertical, (feet)
65
2 Maximum Length Drainage Piping Vertical, (feet)
85
3 Maximum Length Drainage Piping Vertical, (feet)
212
4 Maximum Length Drainage Piping Vertical, (feet)
300
5 Maximum Length Drainage Piping Vertical, (feet)
390
6 Maximum Length Drainage Piping Vertical, (feet)
510
8 Maximum Length Drainage Piping Vertical, (feet)
750
1-1/4 Vent Piping Horizontal and Vertical, Maximum Units
1
1-1/2, Vent Piping Horizontal and Vertical, Maximum Units
8
2 Vent Piping Horizontal and Vertical, Maximum Units
24
3 Vent Piping Horizontal and Vertical, Maximum Units
84
4 Vent Piping Horizontal and Vertical, Maximum Units
256
5 Vent Piping Horizontal and Vertical, Maximum Units
600
6 Vent Piping Horizontal and Vertical, Maximum Units
1380
8 Vent Piping Horizontal and Vertical, Maximum Units
3600
1-1/4 Vent Piping Horizontal and Vertical, Maximum Lengths, (feet)
41
1-1/2, Vent Piping Horizontal and Vertical, Maximum Lengths, (feet)
60
2 Vent Piping Horizontal and Vertical, Maximum Lengths, (feet)
120
3 Vent Piping Horizontal and Vertical, Maximum Lengths, (feet)
212
4 Vent Piping Horizontal and Vertical, Maximum Lengths, (feet)
300
5 Vent Piping Horizontal and Vertical, Maximum Lengths, (feet)
390
6 Vent Piping Horizontal and Vertical, Maximum Lengths, (feet)
510
8 Vent Piping Horizontal and Vertical, Maximum Lengths, (feet)
750