Safety data sheet
The letters SDS are defined as which of the following?
Exposed to the same conditions as apatient sample
Quality control materials should
Human blood
Standard precaution is a practice developed to provide guidance in handling which of the following types of materials?
Risk assessment, quality control plan, quality assessment
What are the 3 steps of an individualized quality control plan (IQCP)?
Add acid to water
When having to add acids and water together, you should always
Occupational Safety and Health Administration (OSHA)
Which agency is responsible for defining, establishing, and monitoring safety and health hazards in the workplace?
Disinfectants
Which of the following is not considered personal protective equipment?
The reproducibilty of a test result
Precision is known as
Running to answer the telephone
An example of a physical hazard in the work enviornment is
Assess the accuracy and precision of a method
The purpose of quaity control materials is to
Prevent the exposure and transmission of potentially infectious agents to personnel
The primary purpose of a Stand Precautions policy in the laboratory is to
Revalidation of test performance
An individualized quality control plan (IQCP) does not require
reporting and interpretation of the results ; Technical testing of the specimen
Examination components of a quality management program are procedures and policies that affect the
Guaranteeing quality patient care ; Ensure that patient test results are precise ; Maximize the productivity of the laboratory
The ultimate goal of quality management is to
A large amount of scatter and uneven distribution
How are precision changes shown on a Levy-Jennings chart?
Ordinary combustible material including paper and wood
A class A fire involves which of the following?
Activate alarm
What is the "A" in the acronym for fire-related emergencies RACE?
Internal QC
The presence of a control line showing up on a pregnancy test if a sufficient amount of specimen has been added to the test system would be an example of
Catalog number
Which of the following information is not found on a safety data sheet?
Turning on the water with a a paper towel ; Rubbing to create friction and a lather ; Rinsing hand in a downward position
Washing your hands according to the CDC guidlines would include all of the following except
Proper use of a fire extinguisher
PASS is an acronym for which of the following?
Critical values
Which of the following is a postexamination component of a quality management system?
Transmission by inhaling dried particles
Airborne transmission means
Patient identification
Which of the following is a preexamination component of a quality assurance program?
Proficiency testing
What is the testing of specimens that are recieved from an outside agency that is followed by the comparison of results with participating laboratories?
Refractive index
Which of the following methods is used to measure specific gravity in automated urinalysis?
Results are corrected for urine color
What is an advantage to semiautomated urinalysis instrumentation?
Digital imaging and flow cytometry
What are the technologies used for automated microscopy analyzers
Is self-calibrating
A semiautomated urine analyzer
Urine particles are automatically classified into 12 categories
Which of the following statements about the iQ200 microscopy analyzer is true?
Clinitek AUWi Pro System
Of the following, which is a complete urinalysis automated system?
Hematology
What type of analyzer does Sysmex utilize for automated body fluid counts?
Semiautomated urinalysis
Which of the following is considered waived testing under CLIA guidelines?
To improve reproducability, increase productivity, ensure standardization for reporting results
The ultimate goal of urinalysis automation is
Squamous epithelial cell
Which of the following would be a "flagged" particle requiring review from an automated microscopic examination?
Increases the time required for the microscopid examination
The benefits of performing automated urine microscopy include all of the following except
UN-2000
What system utilized the Urinalysis Data Manager?
Increased turn around time
Advantages of an automated urine microscopy analyzer over manual microscopy does not include
Renal tubular epithelial cell
What urine sediment would be "flagged" by an automated microscopy analyzer for review?
Unable to count low numbers of white blood cells and malignant cells
A disadvantage of using an automated instrument to count body fluids instead of counting them manually with a hemocytometers is
XN Series ; iQ 200
What automated body fluid analyzer does not need to dilute or pretreat the body fluid before analysis?
Reflectance photometry
Which of the following is not an automated method for urine clarity?
The reagent strip is dipped into the well-mixed urine
Concerning fully automated urine chemistry analyzers which of the following is not true