National Building Code of the Philippines
Presidential Decree No. 1096
Signed by
Ferdinand Marcos
Adopting a NBCP
Republic Act No. 6541
Chapter 1
General Provision
Section 102
Declaration of Policy
Section 102
Declared to the policy of the State to SAFEGUARD life, health, property, and public welfare
Section 103
Scope and Application
Section 103 A
The provisions of this Code shall apply to the design, location, siting, construction, alteration, repair, conversion, use, occupancy, maintenance, moving, demolition of
Section 103 B
Buildings and/or structures constructed before the approval of this Code shall not be affected
Section 104
General Building Requirements
Section 104 A
All buildings or structures as well as accessory facilities thereto shall conform in all respects to the principles of safe construction and must be suited to the purpose for which they are designed.
Section 104 B
Buildings or structures intended to be used for the manufacture/product of any kind of article/product shall observe adequate environmental safeguards.
Section 104 C
Buildings or structures and all parts thereof as well as all facilities found therein shall be maintained in safe, sanitary and good working condition.
Chapter 4
Types of Construction
Section 401
Types of Construction
Type 1 Buildings
Shall be of wood construction.
Type 2 Buildings
Shall be of wood construction with protective fire-resistant materials
One-hour fire-resistive throughout
Except, that permanent non-bearing partitions may use fire-retardant treated wood within the framing assembly.
Type 2 Buildings
Type 3 Buildings
Shall be of masonry and wood construction.
Shall be one-hour fire-resistive throughout
Exterior walls shall be of incombustible fire-resistive construction.
Type 3 Buildings
Type 4 Buildings
Shall be of steel, iron, concrete, or masonry construction.
Walls, ceilings, and permanent partitions shall be of incombustible fire-resistive construction
Except, that permanent non-bearing partitions of one-hour fire-resistive construction may use fire-retardant treated wood within the framing assembly.
Type 5 Buildings
The structural elements shall be of steel, iron, concrete, or masonry construction
Walls, ceilings, and permanent partitions shall be of incombustible fire-resistive construction.
Shall be fire-resistive
Type 5 Buildings
Chapter 7
Classification and General Requirement of All Buildings by Use or Occupancy
Section 701
Occupancy Classified
Section 701 A
Buildings proposed for construction shall be identified according to their use or the character of its occupancy and shall be classified
Group A
Residential Dwellings
Group B
Residentials, Hotels and Apartment
Buildings that accommodates more than 10 persons.
Group B
Group C
Education and Recreation
Buildings used for school or day-care purposes, involving assemblage for instruction, education, or recreation, and not classified in Group I & 2
Group C
Section 701 B
Other subgroupings or divisions within Groups A to J may be determined by the Secretary.
Any other occupancy not mentioned specifically in this Section, or about which there is any question, shall be included in the Group which it most nearly resembles based on the existing or proposed life and fire hazard.
Section 704
Location on Property
Section 704 A
No building shall be constructed unless it adjoins or has direct access to a public space, yard or street on at least one of its sides.
Eaves over required windows shall not be less than 750 millimeters from the side and rear property lines
The purpose of this Section, the center line of an adjoining street or alley shall be considered an adjacent property line.
Section 704 A
Section 707
Maximum Height of Buildings
Section 707
The height measured from the lowest adjoining surface shall not exceed such maximum height by more than 3.00 meters
Except, that towers, spires, and steeples, erected as part of a building and not used for habitation or storage are limited as to height only by structural design if completely of incombustible materials
May extend not to exceed 6.00 meters above the height limits for each occupancy group if of combustible materials.
How to measure the height of the buildings
It shall be measured from the highest adjoining sidewalk or ground surface
Section 708
Minimum Requirements for Group a Dwellings
Section 708 A
Dwelling Location and Lot Occupancy
The dwelling shall occupy not more than 90% of a corner lot
80% of an inside lot
Easements of Light and View of the Civil Code of Philippines, shall be at least 2 meters from the property line.
Section 708 B
Light and Ventilation
Every dwelling shall be so constructed and arranged as to provide adequate light and ventilation as provided under Section 805 to Section 811, of this Code.
Section 708 C
Sanitation
Every dwelling shall be provided with at least one sanitary toilet and adequate washing and drainage facilities.
Section 708 D
Foundation
Footings shall be of sufficient size and strength to support the load of the dwelling
Shall be at least 250 millimeters thick and 600 millimeters below the surface of the ground.
Section 708 E
Post
The dimensions of wooden posts shall be those found in Table 708- A
Each post shall be anchored to such footing by straps and bolts of adequate size
Section 708 F
Floor
The live load of the first floor shall be at least 200 kilograms per square meter
Second floor, at least 150 kilograms per square meter.
Section 708 G
Roof
The wind load for roofs shall be at least 120 kilograms per square meter for vertical projection.
Section 708 H
Stairs
Stairs shall be at least 750 millimeters in clear width, with a rise of 200 millimeters and a minimum run of 200 millimeters.
Section 708 I
Entrance and Exit
There shall be at least one entrance and another one for exit.
Section 708 J
Electrical Requirements
All electrical installation shall conform to the requirements of the Philippine Electrical Code.
Section 708 K
Mechanical Requirements
Mechanical systems and/or equipment installation shall be subject to the requirement of the Philippine Mechanical Engineering Code
Chapter 8
Light and Ventilation
Section 801
General Requirements of light and Ventilation
Section 801 B
All buildings shall face a street or public alley or a private street which has been duly approved.
Section 801 D
No building shall be enlarged so that the dimensions of the required court or yard would be less than that prescribed for such building.
Section 801 C
No building shall be altered nor arranged so as to reduce the size of any room or the relative area of windows to less than that provided for buildings under this Code
Section 802
Measurement of site occupancy
Section 802 A
The measurement of site occupancy or lot occupancy shall be taken at the ground level and shall be exclusive of courts, yards, and light wells.
Section 802 B
Courts, yards, and light wells shall be measured clear of all projections from the walls enclosing
Section 805
Ceiling Heights
Such wells or yards with the exception of roof leaders, wall copings, sills, or steel fire escapes should not exceed?
1.20 meters in width
Habitable rooms provided with artificial ventilation shall have ceiling heights not less than
2.40 meters measured from the floor to the ceiling
Provided that for buildings of more than one-storey, the minimum ceiling height of the first storey shall be
2.70 meters
Provided that for buildings of more than one-storey, the minimum ceiling height of the second storey shall be
2.40 meters
Provided that for buildings of more than one-storey, the succeeding storeys shall have an unobstructed typical head-room clearance of not less than
2.10 meters above the finished floor
Provided that for buildings of more than one-storey, the above stated rooms with a natural ventilation shall have ceiling heights not less than
2.70 meters
Section 805 B
Mezzanine floors shall have a clear ceiling height not less than 1.80 meters above and below it.
Section 806
Size and dimension of rooms
Minimum size of rooms and the least horizontal dimensions for Rooms for Human Habitations
6.00 square meters with a least dimension of 2.00 meters
Minimum size of rooms and the least horizontal dimensions for Kitchens
3.0 square meters with a least dimension of 1.50 meters
Minimum size of rooms and the least horizontal dimensions for Bath and toilet
1.20 square meters with a least dimension of 0.90 meter
Chapter 9
Sanitation
Section 902
Water supply system
Section 902 A
Whenever available, the potable water requirements for a building used for human habitation shall be supplied from existing municipal or city waterworks system.
The quality of drinking water from meteoric, surface or underground sources shall conform to the criteria set in the latest approved
National Standards for Drinking Water.
The design, construction and operation of deepwells for the abstraction of groundwater shall be subject to the provisions of
The Water Code of the Philippines.
Section 902 D
The design, construction and operation of independent waterworks systems private housing subdivisions or industrial estates shall be governed by existing laws relating to local waterworks system
The water piping installations inside buildings and premises shall conform to the provisions of
The National Plumbing Code of the Philippines.
Section 903
Wastewater disposal system
Sanitary sewage from buildings and neutralized or pre-treated industrial wastewater shall be discharged directly into the nearest street sanitary sewer main of existing municipal or city sanitary sewerage system in accordance with the criteria set by
The Code on Sanitation and the National Pollution Control Commission.
Section 903 B
All buildings located in areas where there are no available sanitary sewerage system shall dispose their sewage “Imhoff” or septic tank and subsurface absorption field.
Sanitary and industrial plumbing installations inside buildings and premises shall conform to the provisions of
The National Plumbing Code.
Section 904
Storm drainage system
Section 904 A
Rainwater drainage shall not discharge to the sanitary sewer system.
Section 904 B
Adequate provisions shall be made to drain low areas in buildings and their premises.
Chapter 10
Building projection over public streets
Section 1001
General requirements
No part of any building or structure or any of its appendages shall project beyond
The property line of the building site, except as provided in this Code.
The projection of any structure or appendage over a public property shall be
The distance measured horizontally from the property line to the uttermost point of the projection.
Section 1003
Projection of balconies and appendages over streets
Section 1003 A
The extent of any projection over an alley or street shall be uniform within a block and shall conform to the limitations set forth in Table 1003-A; Projection of Balconies and Appendages (Annex B-2).
The clearance between the established grade of the street and/or sidewalk and the lowest under surface of any part of the balcony shall not be less than
3.00 meters
Section 1005
Canopies (Marquees)
A canopy/marquee
A permanent roofed structure above a door attached to and supported by the building and projecting over a wall or sidewalk. This includes any object or decoration attached thereto.
The horizontal clearance between the outermost edge of the marquee and the curb line shall be not less than
300 millimeters.
The vertical clearance between the pavement or ground line and the undersurface of any part the marquee shall not be less than
3.00 meters.
A marquee shall be constructed of incombustible material or materials of not less than
2-hours fire-resistive construction.
Shall be provided with necessary drainage facility.
Section 1005 D
Every marquee shall be so located as not to interfere with the operation of any exterior standpipe connection or to obstruct the clear passage from stairway exits from the building or the installation or maintenance of electroliers.
Section 1007
Doors, windows, and the like
Section 1007
Doors, windows, and the like less than 2.40 meters above the pavement or groundline shall not, when fully opened or upon opening, project beyond the property line except fire exit doors.
Chapter 12
GSection 1202eneral design and construction requirements