1
New cards
data integrity
instrumentation is important as ____________ helps the signal being collected representing what is being measured
2
New cards
amplitude
the max angle/range a segment travels/moves
3
New cards
frequency
the number of times a segment moves in a cycle
4
New cards
unrestricted
found in healthy people and will have a smaller shear forces in the joints
5
New cards
restricted
often found in unhealthy people and has increased shear forces on joints
6
New cards
analog signal
a transducer turns mechanical into electrical also known as a ______________
7
New cards
transducer
device that converts a form of energy into another
8
New cards
false
transducer will convert electrical to electrical or mechanical

\
t or f
9
New cards
force plate
____________ converts mechanical deformation into electrical energy
10
New cards
LVDT
_____________ converts displacement into electrical energy
11
New cards
continuous
analog information is ______________
12
New cards
discrete
digital information is _______________
13
New cards
true
a computer can only handle digital/binary information, thus analog turns to digital

\
t or f
14
New cards
temporal synchronization
2 devices (ex: video and FP) are synched in respect to time
15
New cards
FP frame = (vid frame-1)\* ratio +1
the equation of a FP frame is _________________
16
New cards
9
if the ratio is 4 FP frames per video frames, then at video frame 3, what is the forceplate frame
17
New cards
17
if the ratio is 4 FP frames per video frames, then at video frame 5 , what is the forceplate frame
18
New cards
false
the sampling frequency should be less than twice the highest frequency

\
t or f
19
New cards
too much data
if the sampling rate is too high then there is
20
New cards
aliasing/erroneous data
if the sampling rate is too low then there is
21
New cards
true
aliasing involves what was being sampled not matching what happened in real life

\
t or f
22
New cards
summation
____________ is the addition of different curves of data with different frequencies
23
New cards
fourier analysis
breaks signal into components (sin waves) with different frequencies
24
New cards
121 Hz
if the signal has a 60 Hz sinewave as it’s highest component what should the sampling frequency
25
New cards
21
if the signal has a 10 Hz sinewave as it’s highest component what should the sampling frequency be
26
New cards
noise
physiological signals are rarely separate from other interfering signals called
27
New cards
systemic noise
this noise is caused from not zeroing the equipment before use
28
New cards
random noise
this noise cannot be corrected and is from soft tissue artifact