Simulation
Radiographic images acquisition
Simulation
Involves computer tomography scans or other imaging studies to help the radiation oncologist plan how to direct the radiation.
Simulation
Assist the physician and other members of the radiation therapy team in the treatment planning process by establishing the appropriate volume to be treated and identifying the normal structures within or adjacent to this volume.
Patient positioning and immobilization
are very significant parts of simulation
Simulation
Patient positioning and immobilization are very significant parts of this process as these will help with the treatment set-up and ensure that the radiation is directed properly each day. This process involves the radiation therapist
Positioning and Immobilization
Tattoo and Marker Placement
Imaging Studies
3 steps of Simulation
Conventional Simulators
Designed to simulate the mechanical, geometric and optical conditions of a variety of units
Conventional Simulators
During ___, patient data are obtained using fluoroscopy, radiography and physical measurements of the patient. This information is then entered into the treatment planning computer
Gantry, treatment couch and controls.
Conventional Simulators Mechanical components:
Gantry
Conventional Simulators: Parts
Rigid C-shaped structure which provides support for both the x-ray tube and film holder system/image intensifier
Isocenter
Conventional Simulators: Parts
✓ The gantry rotates around a fixed point known as the ___
Isocenter
It should be considered as the reference point in space
Isocenter
Generally, it is located 80 to 100 cm from the focal spot and between 100 and 130 cm above the floor
80-100cm
Isocenter is located ____ to ____ from the focal spot
100-130cm
Isocenter is located 80 to 100 cm from the focal spot and between ___ and ___ above the floor
Gantry
Conventional Simulators: Parts
provides stability for the different components of the gantry head.
Collimator assembly
Directs the path of the x-ray beam toward the patient after it emerges from the x-ray tube.
Optical Distance Indicator
Also called as optical range finder (ORF)
Optical Distance Indicator
Also called as range finder
Optical Distance Indicator
-Mounted near the collimator
Optical Distance Indicator
Projects a scale onto the patient’s skin which corresponds to the source skin distance (SSD)
Field Defining Wires
Also known as delineators
Field Defining Wires
Located in the collimator assembly
Field Defining Wires
-Made up of tungsten, Represents the edge of the treatment field
Beam Restricting Diaphragms
Also known as the x-ray shutters, blades or collimators
Beam Restricting Diaphragms
Also located within the collimator assembly
Beam Restricting Diaphragms
-Define both the size and the axis of the x-ray beam through restricting the coverage of the x-ray field
Beam Restricting Diaphragms
Indicate the coverage of the x-ray field.
Beam Restricting Diaphragms
Located at the opposite end of the gantry arm
Imaging/Image intensifier system
Receives and processes the created image
Film holder, Image intensifier, Television camera, Video monitor
Imaging/Image intensifier system four major components
Couchtop
Also known as patient tabletop.
Couchtop
The device in which a patient is positioned during treatment or simulation.
Couchtop
It is essential that the patient tabletop on the simulator provides support identical to that of the patient tabletop on the treatment unit to maintain reproducibility
Couchtop
The surface of the tabletopmust be a hard flat surface that minimally attenuates the x-ray beam
CT Simulators
provides the most useful information for treatment planning purposes because the scans can produce a 3D representation of the patient and external structures
CT Simulators
this simulator outlines the target volume and critical structures, projects treatment beams on to the patient and establishing external reference marks used for treatment setup purposes
gantry, couch and computer control system
major components of CT simulator
X-ray tubes, Detector array, High voltage generator, Mechanical support devices
CT Simulators: Parts
Gantry: The gantry includes the following components:
Treatment Couch
a flat, radiolucent, and often indexable tabletop attachment (usually carbon fiber) placed on a CT scanner couch to match the contour and indexing of a linear accelerator (LINAC) treatment table
Patient Positioning
it is one of the weakest link in treatment planning process
Stable, Comfortable, Minimizes movements, Reproducible
Good patient position is ALWAYS:
Immobilization devices
are medical tools used to stabilize, support, or restrict movement of a specific body part, ensuring precision during radiotherapy