Sanitary Engineer

301.5.1 Permit Application. The registered _____________ shall indicate on the design documents that the plumbing system, or parts thereof, is an alternative engineered design so that it is noted on the construction permit application. The permit and permanent permit records shall indicate that an alternative engineered design was part of the approved installation.

2
New cards

5

Design Documents. The registered Sanitary Engineer shall provide ______, or as required complete sets of signed and sealed design documents for the alternative engineered design for submittal to the Authority Having Jurisdiction. The design documents shall include floor plans and a riser diagram of the work.

3
New cards

flow, pipe sizes, grade of horizontal piping, loading, and location of fixtures

Where appropriate, the design documents shall indicate the direction of ____________ and appliances. 301.4.4 UPCP

4
New cards

double hub fitting

single or double tee branch

single or double tapped tee branch

side inlet quarter bend

running thread

band

saddle

310.0 Prohibited Fittings and Practices.310.1 Fittings. No _______, __________, _____________, __________, ________, ______, or __________ shall be used as a drainage fitting.

5
New cards

cast-iron

310.2 Drainage and Vent Piping. No drainage or vent piping shall be drilled and tapped for the purpose of making connections thereto, and no _______ soil pipe shall be threaded.

6
New cards

0.10 psi (0.69 kPa)

Pressure Tests (10 psi or less). Required pressure tests of 10 pounds-force per square inch (psi) (69 kPa) or less shall be performed with gauges of ____________________ incrementation or less.318.2

7
New cards

100 psi (689 kPa)

318.3 Pressure Tests (greater than 10 psi to 100 psi). Required pressure tests exceeding 10 psi (69 kPa) but less than or equal to _____________ shall be performed with gauges of 1 psi (7 kPa) incrementation or less.

8
New cards

2 percent

318.4 Pressure Tests (exceeding 100 psi). Required pressure tests exceeding 100 psi (689 kPa) shall be performed with gauges incremented for ________ or less of the required test pressure.

9
New cards

1/2

Rod Size- Pipe and Tube Sizes

5-8

10
New cards

3/8

Rod Size- Pipe and Tube Sizes

1/2 - 4

11
New cards

5/8

Rod Size- Pipe and Tube Sizes

10 - 12

12
New cards

5 feet, except 10 feet where 10 foot lengths are installed

1,2, 3

Cast with Lead and oakum joint shall be supported horizontally

13
New cards

Base and each floor,

not to exceed 15 feet

Cast with Lead and oakum joint shall be supported vertically

14
New cards

Every other joint, unless over 4 feet

then support each joint

1, 2, 3

Cast with Compression Gasket Joint shall be supported horizontally

15
New cards

Base and each floor,

not to exceed 15 feet

Cast with Compression Gasket Joint shall be supported vertically

16
New cards

Every other joint, unless over 4 feet

then support each joint

1,2,3,4

Cast-Iron Hubless shall be supported horizontally

17
New cards

Base and each floor,

not to exceed 15 feet

Cast-Iron Hubless shall be supported vertically

18
New cards

Shielded Coupling

Types of Joint Cast-Iron Hubless

19
New cards

1-1/2 inches and smaller, 6 feet;

2 inches and larger. 10 feet

Copper & Copper Alloys shall be supported horizontally

20
New cards

Each floor, not to exceed 10 feet5

Copper & Copper Alloys shall be supported vertically

21
New cards

Soldered, Brazed, Threaded, or Mechanical

Types of Joint Copper & Copper Alloys

22
New cards

3/4 inch and smaller, 10 feet;

1 inch and larger. 12 feet

Steel Pipe for Water or DWV shall be supported horizontally

23
New cards

Every other floor,

not to exceed 25 feet5

Steel Pipe for Water or DWV shall be supported vertically

24
New cards

Threaded or Welded

Types of Joint Steel Pipe for Water or DWV

25
New cards

1/2 inch, 6 feet; 3/4 inch and 1 inch,

8 feet: I-1/4 inches and larger, 10 feet

Steel Pipe for Gas shall be supported horizontally

26
New cards

1/2 inch, 6 feet; 3/4 inch and 1 inch,

8 feet: 1-1/4 inches every floor level

Steel Pipe for Gas shall be supported vertically

27
New cards

Threaded or Welded

Types of Joint Steel Pipe for Gas

28
New cards

All sizes, 4 feet; allow

for expansion every 30 feet

Schedule 40 PVC ABS DWV and shall be supported horizontally

29
New cards

Base and each floor; provide

mid-story guides; provide

for expansion every 30 feet

Schedule 40 PVC ABS DWV and shall be supported vertically

30
New cards

Solvent Cemented

Types of Joint Schedule 40 PVC ABS DWV

31
New cards

1 inch and smaller, 3 feet:

1-1/4 inches and larger, 4 feet

CPVC shall be supported horizontally

32
New cards

Base and each floor;

provide mid-story guides

CPVC shall be supported vertically

33
New cards

Solvent Cemented

Types of Joint CPVC

34
New cards

1/2 inch, 5 feet; 3/4 inch, 65 inches;

1 inch, 6 feet

CPVC-AL-CPVC shall be supported horizontally

35
New cards

Base and each floor;

provide mid-story guide

CPVC-AL-CPVC shall be supported vertically

36
New cards

Solvent Cemented

Types of Joint CPVC-AL-CPVC

37
New cards

Continuous Support

Lead shall be supported horizontally

38
New cards

Not to exceed 4 feet

Lead shall be supported vertically

39
New cards

Wiped or Burned

Types of Joint Lead

40
New cards

In accordance with the standards acceptable to the Authority Having Jurisdiction

Steel shall be supported horizontally and vertically

41
New cards

Mechanical

Types of joint Steel

42
New cards

1 inch and smaller, 32 inches

1-1/4 inches and larger, 4 feet

PEX shall be supported horizontally

43
New cards

Base and each floor;

provide mid-story guides

PEX shall be supported vertically

44
New cards

Cold Expansion, Insert

and Compression

Types of joint PEX

45
New cards

1/2 inch, 3/4 inch, 1 inch- All sizes 98 inches.

PEX-AL-PEX shall be supported horizontally

46
New cards

Base and each floor;

provide mid-story guides

PEX-AL-PEX shall be supported vertically

47
New cards

Metal Insert and Metal

Compression

Types of Joint PEX-AL-PEX

48
New cards

1/2 inch, 3/4 inch, 1 inch- All sizes 98 inches

PE-AL-PE shall be supported horizontally

49
New cards

Base and each floor;

provide mid-story guides

PE-AL-PE shall be supported vertically

50
New cards

Metal Insert and Metal

Compression

Types of Joint PE-AL-PE

51
New cards

1 inch and smaller, 32 inches

1-1/4 inches and larger, 4 feet.

PE-RT shall be supported horizontally

52
New cards

Base and each floor;

provide mid-story guides

PE-RT shall be supported vertically

53
New cards

Insert and Compression

Types of Joint PE-RT

54
New cards

1 inch and smaller, 32 inches

1-1/4 inches and larger, 4 feet

Polypropylene (PP) shall be supported horizontally

55
New cards

Base and each floor;

provide mid-story guides

Polypropylene (PP) shall be supported vertically

56
New cards

Fusion weld (socket, butt, sad-

dle, electrofusion), threaded

(metal threads only), or

mechanical

Types of Joint Polypropylene (PP)