Sanitary Engineer
301.5.1 Permit Application. The registered _____________ shall indicate on the design documents that the plumbing system, or parts thereof, is an alternative engineered design so that it is noted on the construction permit application. The permit and permanent permit records shall indicate that an alternative engineered design was part of the approved installation.
5
Design Documents. The registered Sanitary Engineer shall provide ______, or as required complete sets of signed and sealed design documents for the alternative engineered design for submittal to the Authority Having Jurisdiction. The design documents shall include floor plans and a riser diagram of the work.
flow, pipe sizes, grade of horizontal piping, loading, and location of fixtures
Where appropriate, the design documents shall indicate the direction of ____________ and appliances. 301.4.4 UPCP
double hub fitting
single or double tee branch
single or double tapped tee branch
side inlet quarter bend
running thread
band
saddle
310.0 Prohibited Fittings and Practices.310.1 Fittings. No _______, __________, _____________, __________, ________, ______, or __________ shall be used as a drainage fitting.
cast-iron
310.2 Drainage and Vent Piping. No drainage or vent piping shall be drilled and tapped for the purpose of making connections thereto, and no _______ soil pipe shall be threaded.
0.10 psi (0.69 kPa)
Pressure Tests (10 psi or less). Required pressure tests of 10 pounds-force per square inch (psi) (69 kPa) or less shall be performed with gauges of ____________________ incrementation or less.318.2
100 psi (689 kPa)
318.3 Pressure Tests (greater than 10 psi to 100 psi). Required pressure tests exceeding 10 psi (69 kPa) but less than or equal to _____________ shall be performed with gauges of 1 psi (7 kPa) incrementation or less.
2 percent
318.4 Pressure Tests (exceeding 100 psi). Required pressure tests exceeding 100 psi (689 kPa) shall be performed with gauges incremented for ________ or less of the required test pressure.
1/2
Rod Size- Pipe and Tube Sizes
5-8
3/8
Rod Size- Pipe and Tube Sizes
1/2 - 4
5/8
Rod Size- Pipe and Tube Sizes
10 - 12
5 feet, except 10 feet where 10 foot lengths are installed
1,2, 3
Cast with Lead and oakum joint shall be supported horizontally
Base and each floor,
not to exceed 15 feet
Cast with Lead and oakum joint shall be supported vertically
Every other joint, unless over 4 feet
then support each joint
1, 2, 3
Cast with Compression Gasket Joint shall be supported horizontally
Base and each floor,
not to exceed 15 feet
Cast with Compression Gasket Joint shall be supported vertically
Every other joint, unless over 4 feet
then support each joint
1,2,3,4
Cast-Iron Hubless shall be supported horizontally
Base and each floor,
not to exceed 15 feet
Cast-Iron Hubless shall be supported vertically
Shielded Coupling
Types of Joint Cast-Iron Hubless
1-1/2 inches and smaller, 6 feet;
2 inches and larger. 10 feet
Copper & Copper Alloys shall be supported horizontally
Each floor, not to exceed 10 feet5
Copper & Copper Alloys shall be supported vertically
Soldered, Brazed, Threaded, or Mechanical
Types of Joint Copper & Copper Alloys
3/4 inch and smaller, 10 feet;
1 inch and larger. 12 feet
Steel Pipe for Water or DWV shall be supported horizontally
Every other floor,
not to exceed 25 feet5
Steel Pipe for Water or DWV shall be supported vertically
Threaded or Welded
Types of Joint Steel Pipe for Water or DWV
1/2 inch, 6 feet; 3/4 inch and 1 inch,
8 feet: I-1/4 inches and larger, 10 feet
Steel Pipe for Gas shall be supported horizontally
1/2 inch, 6 feet; 3/4 inch and 1 inch,
8 feet: 1-1/4 inches every floor level
Steel Pipe for Gas shall be supported vertically
Threaded or Welded
Types of Joint Steel Pipe for Gas
All sizes, 4 feet; allow
for expansion every 30 feet
Schedule 40 PVC ABS DWV and shall be supported horizontally
Base and each floor; provide
mid-story guides; provide
for expansion every 30 feet
Schedule 40 PVC ABS DWV and shall be supported vertically
Solvent Cemented
Types of Joint Schedule 40 PVC ABS DWV
1 inch and smaller, 3 feet:
1-1/4 inches and larger, 4 feet
CPVC shall be supported horizontally
Base and each floor;
provide mid-story guides
CPVC shall be supported vertically
Solvent Cemented
Types of Joint CPVC
1/2 inch, 5 feet; 3/4 inch, 65 inches;
1 inch, 6 feet
CPVC-AL-CPVC shall be supported horizontally
Base and each floor;
provide mid-story guide
CPVC-AL-CPVC shall be supported vertically
Solvent Cemented
Types of Joint CPVC-AL-CPVC
Continuous Support
Lead shall be supported horizontally
Not to exceed 4 feet
Lead shall be supported vertically
Wiped or Burned
Types of Joint Lead
In accordance with the standards acceptable to the Authority Having Jurisdiction
Steel shall be supported horizontally and vertically
Mechanical
Types of joint Steel
1 inch and smaller, 32 inches
1-1/4 inches and larger, 4 feet
PEX shall be supported horizontally
Base and each floor;
provide mid-story guides
PEX shall be supported vertically
Cold Expansion, Insert
and Compression
Types of joint PEX
1/2 inch, 3/4 inch, 1 inch- All sizes 98 inches.
PEX-AL-PEX shall be supported horizontally
Base and each floor;
provide mid-story guides
PEX-AL-PEX shall be supported vertically
Metal Insert and Metal
Compression
Types of Joint PEX-AL-PEX
1/2 inch, 3/4 inch, 1 inch- All sizes 98 inches
PE-AL-PE shall be supported horizontally
Base and each floor;
provide mid-story guides
PE-AL-PE shall be supported vertically
Metal Insert and Metal
Compression
Types of Joint PE-AL-PE
1 inch and smaller, 32 inches
1-1/4 inches and larger, 4 feet.
PE-RT shall be supported horizontally
Base and each floor;
provide mid-story guides
PE-RT shall be supported vertically
Insert and Compression
Types of Joint PE-RT
1 inch and smaller, 32 inches
1-1/4 inches and larger, 4 feet
Polypropylene (PP) shall be supported horizontally
Base and each floor;
provide mid-story guides
Polypropylene (PP) shall be supported vertically
Fusion weld (socket, butt, sad-
dle, electrofusion), threaded
(metal threads only), or
mechanical
Types of Joint Polypropylene (PP)