< 0 F
[653: 10.4.2.3]
Reconstruction- Base metal temp where welding is not allowed
0 - 32 F
[653: 10.4.2.3]
Reconstruction- Base metal temp when hand-warm pre-heat is required
5 F above dew point
[652: 8.3]
Linings- Minimum temp when installing tank bottom linings
18 F
[651: 5.4.1 Note]
Corrosion- The corrosion rate of steel tank bottoms may double with this rise in temperature
25 F
[577: 8.9.3.1]
UT Calibration- Calibration Block must be within what temperature of the part to be examined
10-350 F
[571: 3.22.3.a.1]
Corrosion - CUI temperature range for CS & 400 Series SS
40-125 F
[650: 8.6.6]
Vacuum Box - Standard temperature range for VB exam
40- 125 F
[V: T-652/653]
PT- Standard temperature range for a PT exam
< 50 F
[650: 9.2.2.3]
Impact Test- Design metal temperature that requires weld procedure used for vertical welds to be impact tested
> 60 F
[653: Fig 5.1]
Brittle- Tank metal temperature where brittle fracture is NOT a concern
> 100 F
[653: 9.11.1.2.3]
Bottom Lap Patches- Metal temp where lap patches are NOT allowed in critical zone on SS tank
< 110 F
[653:6.4.2.1.2.1]
Intervals- If tank product solidify below this temperature, the code maximum interval rules do not apply
140- 350 F
[571: 3.22.3.a.2]
Corrosion- CUI temperature range for 300 Series SS
> 150 F [575: 8.4.4]
> 170 F [571: 3.14.3.b]
Corrosion- Temperature when high strength caustic causes general corrosion in CS. Both API 571 and 575 answers.
170-230 F
[575: 8.2.8]
Corrosion- Most aggressive temperature range for CUI
200 F
[653: 10.4.4.3]
Preheat- Required pre-heat temperature for shell welds over 1.5” thick during reconstruction
> 200 F
[653: 9.11.1.2.3]
Bottom Lap Patches- Metal temperature where lap patches are NOT allowed in the critical zone on CS tanks
200-500F
[650: 1.1.20]
Design- Temperature Range for API 650 Annex M
300 F
[653: 11.3.1.d]
Preheat- Minimum pre-heat temperature, when pre-heat is substituted for PWHT
1000 F
[V: SE-797 9.5]
NDE- Maximum temperature for UT thickness readings
1100-1200 F
[650: 5.7.4.1/2]
PWHT- Standard PWHT Temperature specified in API 650
1350 F
[577: 10.2.4]
Welding: CS HAZ- Base metal that did NOT melt but exceeded this temp during welding