IDFX Codes

0.0(0)
studied byStudied by 2 people
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
Card Sorting

1/34

encourage image

There's no tags or description

Looks like no tags are added yet.

Study Analytics
Name
Mastery
Learn
Test
Matching
Spaced

No study sessions yet.

35 Terms

1
New cards

NFPA 70

also known as NEC National Electric Code -governs electrical installations

2
New cards

**NFPA 80

Standard for fire doors and other opening protectives

3
New cards

NFPA 101

Life safety code- focuses on building occupant protection

4
New cards

**NFPA 252

standard methods of fire tests of door assemblies

5
New cards

**NFPA 253 (ASTM E648)

Flooring radiant panel test - tests and measures a carpets flame spread in a corridor or exit way. higher number = more resistant

6
New cards

**NFPA 258 (ASTM E662)

smoke density test/smolder resistance test - measures the amount of smoke from a flaming or smoldering material for wall finishes

7
New cards

** NFPA 265/UL 1715

Room corner test for textiles - determines the contribution of interior wall and ceiling coverings to room fire growth (like NFPA 258, but stimulates real-world conditions by testing in the corner of a test room)

addresses specifically textiles and expanded vinyl coverings (wallcoverings) on walls & ceilings

8
New cards

**NFPA 269

toxic potency data for fire hazard modeling -protects people from toxic smoke of a combustible material when ignited

9
New cards

NFPA 286

room corner test for textiles - determines the contribution of interior wall and ceiling coverings to room fire growth (like NFPA 258, but stimulates real-world conditions by testing in the corner of a test room)

addresses all other wall & ceiling finish materials (leather, cork, etc.) that are NOT tested in NFPA 265

10
New cards

**NFPA 701

vertical flame test - flame propagation test for vertical treatments (curtains, drapes, window shades, etc)

11
New cards

**AATCC 8 - Crocking resistance test

determines the resistance of a dyed or printed fabric textile to transfer color to other surfaces by rubbing

12
New cards

AATCC 16 - fade-ometer

tests colorfastness to light

13
New cards

ASTM C423

test method for sound absorptions coefficients by reverberation room method

14
New cards

ASTM F462

standard consumer safety specification for slip-resistant bathing facilities

15
New cards

**ASTM E84/UL 723

steiner tunnel test - used to test flame spread of wall finishes (upholstery, wallcovering, etc)

16
New cards

ASTM E1678

standard test method for measuring smoke toxicity for use in fire hazard analysis

17
New cards

ASTM E2257

room fire test of wall and ceiling materials and assemblies

18
New cards

ASTM E2573

site fabricated stretch wall systems mounting - must comply with ASTM E84

19
New cards

**ASTM D2047

standard test method for static coefficient of friction of polish-coated flooring surfaces as measured by the James machine. can only be performed on smooth, dry surfaces in the laboratory. it should not be used for wet or rough surfaces

20
New cards

**ASTM D2859

methenamine pill test - used to measure general flame resistance of carpet flooring

21
New cards

**ASTM D3884

The taber abraser test - measures carpet abrasion resistance

22
New cards

**ASTM D4157

The wyzenbeek abrasion resistance test - measures the resistance of woven textile fabrics in double rubs. for this test a minimum of 30,000 double rubes is required for commercial use. considered the industry standard abrasion resistance test for durability of woven textile fabrics for heavy duty commercial use.

23
New cards

**ASTM D4966

Martindale abrasion test - similar to the wyzenbeek test but usually applied to fabrics with a pile depth of less than 0.08 inches and tests in figure 8 rub. for this test a minimum of 40,000 double rubs is required for commercial use.

24
New cards

ASTM D5116

VOc emissions from indoor materials (small chamber)

25
New cards

ASTM D6670

VOC emissions (full-scale chamber test)

26
New cards

**CAL TB 116/ NFPA 261

cigarette ignition resistance testing of upholstered furniture material. assemblies as a whole, it determines how the composite mater (padding and covering) reacts to a lighted cigarette

27
New cards

**CAL TB 117-2013 (ASTM E1353/NFPA 260)

The smolder resistance test or cigarette ignition test - tests how a furniture will smolder before either flaming or extinguishing an actual smoldering cigarette as the ignition source, most common product is resilient filling materials

28
New cards

**BIFMA E3

commercial furniture sustainability standard

29
New cards

**BIFMA X7.1

within BIFMA E3, this is the standard for formaldehyde and TVOC emissions of low emitting office furniture systems and seating

30
New cards

NSF/ANSI 336

FACTS is based on this standard, addresses the environmental, economic, and social aspects of interior design commercial textiles

31
New cards

ANSI A137.1

the american national standard specifications for ceramic tile

32
New cards

ANSI A326.3

DCOF (dynamic coefficient of friction) test method for hard surface flooring

33
New cards

ASHRAE 62.1

ventilation for acceptable indoor air quality

34
New cards

ANSI/ASHRAE 62.2

ventilation and acceptable indoor air quality in low rise buildings

35
New cards

3 tests used to measure the moisture level of a concrete floor

calcium chloride test

hygrometer test

relative humidity test