A project seeking LEED Certification needs a minimum number of credits under Building product disclosure and optimization — sourcing of raw materials, which gives preference for bio-based renewable materials.

Which of the following materials should the designer reselect?

marble flooring

2
New cards

Which test is NOT used to determine flammability of upholstery fabric?

radiant panel test

3
New cards

Of 100 possible points, how many are required to

achieve the Facts Compliant level?

16 points are required

4
New cards

What attributes does the BIFMA e3, Furniture

Sustainability Standard consider when addressing

sustainability?

material utilization, energy impacts,

ecosystem health, social responsibility.

5
New cards

What is the relationship between NSF/ANSI 336 and

Facts?

Facts is based on NSF/ANSI 336

6
New cards

When selecting the upholstery and window

treatment fabrics for a hotel lobby design, which of the

following standards would NOT be a consideration for

the fabric?

NFPA 257

7
New cards

A Facts assessment is divided into two main parts,

each covering 50 percent of the assessment. Which are

they?

Fabric composition and manufacturing process

8
New cards

During a renovation, when products and materials

cannot be reused or recycled, they are disposed of in a

landfill.

What type of product would BEST minimize the

quantity of items that go to a landfill and also save raw

materials?

biobased products

9
New cards

Which of these are true regarding the Facts

certification?

-Is the only sustainability certification program

for commercial textiles

-Is based on the rigorous and comprehensive

multi-attribute standard NSF/ANSI 336

-Requires authorized independent third-party

certification

10
New cards

What is NOT considered part of a Code of Ethics?

a code of ethicc is considered standards of law

11
New cards

The main focus of the NCIDQ Examinations is on

“health, safety and welfare” because:

these are affected by every decision made by an interior designer

12
New cards

Social Responsibility within the profession of Interior

Design includes a number of types of services and

actions.

Which is NOT one of those socially responsible

services or actions given or provided by a designer?

appearing on TV to talk about their services

13
New cards

The minimum clear width for a door is:

32 inches (815 mm)

14
New cards

What should be the minimum distance between

exits within a space?

one half the diagonal distance of the room area

15
New cards

Horizontal grab bars at the side-wall of an

accessible toilet must be mounted at:

33” (840 mm) - 36” (900 mm) AFF

16
New cards

There are a number of considerations that are

important in designing a safe and accessible residential

bathroom. Which is the most important?

There should be at least 30×48 inches of clear space in front of an accessible shower

17
New cards

Why is it important to coordinate the locations of

audible and visual (A/V) alarms with the appropriate

consulting engineer?

to ensure that audible and visual (A/V) alarms can be seen and heard where requuired

18
New cards

The controls for all accessible (barrier free) wall

mounted restroom accessories must be located how

many inches/mm AFF for a SIDE reach:

15” (380 mm) - 48” (1220 mm)

19
New cards

When designing an accessible toilet stall, all of the

following apply EXCEPT?

there must be at least one grab bar at the toilet

20
New cards

how do you prevent spread of fire and smoke to adjacent spaces in the plenum of a multi-story building?

use of fire-rated dividers

21
New cards

which is the most important requirement for exits?

protected by fire-rated construction

22
New cards

the common path of egress travel distance cannot exceed: assume a sprinklered building, business occupancy spaces with 1 exit or exit access doorway

100 feet (30.5 m)

23
New cards

How many exits are required for a single-tenant

office space of 2,500 square feet (232.25 square

meters), with a common path of egress travel distance

of 125 feet (38.1 m)?

two

24
New cards

territoriality is best described as?

a fundamental aspect of human behavior that attempts to lay claim to the space people occupy and the things they own

25
New cards

in terms of color, value is best desccribed as?

the degree of lightness or darkness of color in relation to white and black

26
New cards

Sensory considerations when designing egress and

other accessible portions of a project should include

what combination of elements?

visual and tactile elements

27
New cards

The senses of sound, sight, and smell play a large

factor in egress from a building during an emergency

situation as they help define the threat level of panic.

smelling smoke, hearing breaking glass, awareness of alarm bells, sight of flames

28
New cards

When designing egress and other accessible

portions of a project, what combination of elements

should be included with regard to sensory

considerations?

visual and tactile elements

29
New cards

All of the following relate to the design principle

proportion EXCEPT?

gestalt psychology

30
New cards

In the plan below an overall dimension is given and

the spaces are shown with a dimension string.

What is the name for the dimension not identified?

open dimension

31
New cards

Specialized items such as artwork, plants, graphics,

and special free-standing or constructed items are

considered as part of which program?

furnishings

32
New cards

What kind of drawing is the most common for

complex ceiling systems in large commercial projects?

reflected ceiling plan

33
New cards

What type of plan is shown in this image?

This image shows a reflected ceiling plan

34
New cards

In the kitchen and bath industry, the size of cabinetry

in the drawings is often expressed in numbers which

include the __________________________ of the

manufactured units.

width, height, and depth

35
New cards

What is the best way to show finish placement for a

project with spaces that have 2 finishes, such as paint

and wallcovering?

Use a combination of lines, symbols, and elevations on a finish plan

36
New cards

While working on the design for a high-end conference room, which drawing type in the construction documents would be used to indicate the vertical

extents of millwork as well as the configuration of fabric panels located above the millwork?

elevation

37
New cards

In a project for a large call center, which plan would show the locations of computers?

power or communications plan

38
New cards

This part of a dimension string can be used to accommodate minor discrepancies in the final floor plan.

open dimension as it is only used where exact dimensions are not critical

39
New cards

In a small lounge area with exposed mechanical systems, you have designed two walls to receive a custom wood planked finish on the entire wall up to 10’.

Above this 10′-0″ (3.04 m) mark, the wall will continue with a painted finish into the exposed plenum space.

What gypsum wallboard finish level would be most appropriate for this wall?

Level 3: Similar to Level 2, except two coats of joint compound are used, and the surface is free of tool marks and ridges. This level is used where the surface receives heavy- or medium- textured finishes or heavy-grade wallcoverings will be applied.

40
New cards

Solid stock lumber is cut from a log in all of the following ways EXCEPT?

rotary sawing

41
New cards

You are designing a small project that measures 20′ (6096 mm) x 16′ (4877 mm). The total FF&E budget is $18,000. You have spent $15,000 for furniture and equipment and $1900.00 for painting and wall coverings (installed).

How much per yard can you spend on carpet that is 12′ (3658 mm) wide?

$25.50

42
New cards

Using the square foot calculation method, determine the quantity of wallpaper at 27″ (686 mm) wide [each single roll covers 36 sq ft (3.35 m2)] needed for a room that is 20 ft(6096 mm) x 25 ft(7620 mm) with 10 ft(3048 mm) high ceilings.

The room has a 5 ft(1524 mm) x 6 ft(1829 mm) window, two 2 ft(610 mm) x 3 ft(915 mm) windows and one 3 ft(915 mm) x 7 ft(2134 mm) door.

How many double rolls are required?

15 double rolls

43
New cards

Level 4 gypsum wallboard finish is MOST suitable for which of the following applications?

Areas where eggshell finish paints are to be applied as a final finish where economy is of concern

44
New cards

The following describes which type of flooring: Composed from various resins, fibers, plasticizers, and/or fillers, this material is formed under heat and

pressure to produce a thin material, either sheets or tiles. This is applied with mastic to a subfloor of concrete, plywood or other smooth underlayment.

resilient flooring

45
New cards

Which of these materials would be best used on the subfloor to prevent squeaking, allows for expansion, and keep moisture from seeping up below a wood floor?

#15 asphalt felt and polyethylene film

46
New cards

an adjacency matrix is used to:

establish space planning relationship and priorities

47
New cards

Which of the following drawing is most synonymous with a parti diagram?

napkin sketch

48
New cards

Ideas are sketched, during the schematic design phase, in abstract forms/shapes in plan view that represent the program’s spaces, activities, and

circulation patterns. What are these conceptual sketches referred to as?

bubblee diagrams

49
New cards

During programming interviews, when a client offers important verbal information, the sketches that are developed to document them are often called what?

precept diagrams

50
New cards

Which diagram is part of the schematic design phase and used to move from verbal and simplified graphic notation toward true scale and the eventual

realization of architectural form?

block plan

51
New cards

Which type of matrix records the relationships between rooms in a plan and identifies the required levels of closeness and reasons why rooms need to be

near each other?

adjacency matrix

52
New cards

The complexity of the human environment interface makes it difficult to base a design theory only on

environmental design research

53
New cards

which best describes a bubble diagram?

a way to address issues including lighting and acoustics in the planning phase

54
New cards

Which of the following existing conditions influences the space plan of an interior design project?

ornate millwork

location of plumbing

an undesirable view

all of these

55
New cards

This measuring technique creates a “point cloud” forming a 3D image of the object or space being measured.

laser scanning

56
New cards

When starting a project within a structure located within a designated historic district, why is an historical analysis important?

the “historical significance” must be taken into account when applying accessibility requirements

57
New cards

Which scenario is best suited to hand measuring?

measuring spaces of moderate size and complexity