The recovery process on an R-12 or R134a A/C system should continue until a stable vacuum is held by the system for:

2 Minutes

2
New cards

A recycled refrigerant container has been checked and found to be above the given pressure limit for the ambient temperature.Technician A says that the refrigerant container should be placed in a cooler storage area before use.Technician B says that the vapor in the container should be slowly vented into a refrigerant handling unit.Who is right?

B only

3
New cards

The ozone layer filters out most of the sun's harmful:

Ultraviolet radiation

4
New cards

The reduction of ozone in the stratosphere could cause:

an increase in skin cancer and eye cataracts.

5
New cards

Technician A says that sunlight striking CFC molecules can cause chlorine to be released.Technician B says that chlorine atoms react with ozone to produce chlorine monoxide.Who is right?

Both A and B

6
New cards

R-134a refrigerant must be reclaimed to meet which of these purity standards?

J2099

7
New cards

If the required charge level of refrigerant for the MVAC system is 40 ounces, which of these is the correct charge level measured in pounds?

2.50Lb (1.13kg)

8
New cards

Technician A says that recovery/recycling/recharging equipment for R-1234yf refrigerant requires integration with a refrigerant identifier.Technician B says that recovery/recycling/recharging equipment for R-1234yf refrigerant uses a 17mm O.D. quick coupler on the low-side service hose.Who is right?

A only

9
New cards

Which of these identifies a cylinder of R-1234yf refrigerant?

White with red band

10
New cards

A container of recycled R-134a refrigerant that is being tested for non-condensable gases (air) should be:

Stored out of direct sunlight

11
New cards

The EPA allows the use of R-134a recovery-only equipment provided that the

equipment meets J2810 standards

12
New cards

Technician A says that it is OK to use a disposable refrigerant tank to store recycled refrigerant.Technician B says that it is OK to fill an approved refrigerant tank to 70% of its gross weight rating.Who is right?

Neither A or B

13
New cards

Before a container of stored recycled refrigerant is used, the container must be checked for:

non-condensable gases

14
New cards

Recovery equipment for R-134a refrigerant must meet standards set by

SAE

15
New cards

Alternative refrigerants use a unique set of service fittings that

prevent accidental mixing of refrigerants

16
New cards

Technician A says that R-744 refrigerant is accepted by the EPA as an alternative for retrofit.Technician B says that R-134a refrigerant is accepted by the EPA as an alternative for retrofit.Who is right?

B only

17
New cards

SAE standard J2099 specifies that the maximum level of non-condensable gases in recycled R-134a should not exceed

1.5% by volume

18
New cards

When service equipment hoses with manual shutoff valves are not connected to an A/C system, the valves should be in the

Closed position

19
New cards

MVAC refrigerant R-1234yf has a

pressure/temperature relationship like R-134a

20
New cards

A technician who successfully completes the training and certification in the EPA-approved Section 609 program can legally service MVAC systems that use any of these refrigerants EXCEPT

R-22

21
New cards

Electronic leak detectors for R-1234yf should meet

J2913

22
New cards

Technicians servicing an MVAC system should do any of these EXCEPT

Store refrigerant in a disposable container

23
New cards

Requirements for recovery/recycling/recharging equipment for R-1234yf refrigerant are set by SAE standard

J2843

24
New cards

R-1234yf refrigerant has a global warming potential (GWP) of

4

25
New cards

R-1234yf is a preferred refrigerant over R-134a because

It has a low GWP

26
New cards

Technician A says that SAE standard J639 spells out details for a system design, implementation, and serviceTechnician B says that SAE standard J639 specifies refrigerant fitting types and sizes for each refrigerant.Who is right?

Both A and B

27
New cards

Servicing MVAC systems on hybrid and electric vehicles requires

Special service procedures to disable the high-voltage system prior to service

28
New cards

To purchase R-1234yf refrigerant for MVAC service, a person must:

Have a valid EPA-approved Section 609 credential.

29
New cards

Which of the following refrigerants is listede as unacceptable under SNAP for all newly manufactured vehicles as of the 2026 model year

HFC-134a (R-134a)

30
New cards

Empty disposable R-134a refrigerant containers should be

evacuated into a recovery/recycling machine