311 numbers

studied byStudied by 0 people
0.0(0)
Get a hint
Hint

5 to 10 degrees but not less than 15 degrees

1 / 67

flashcard set

Earn XP

Description and Tags

68 Terms

1

5 to 10 degrees but not less than 15 degrees

Target angulation

New cards
2

100%

Voltage ripple of single phase generator

New cards
3

14%

Voltage ripple of 3phase 6pulse generator

New cards
4

4%

Voltage ripple of 3phase 12pulse generator

New cards
5

Less than 1%

Voltage ripple of high frequency generator

New cards
6

Greater than 3 hrs

Rest for xrt

New cards
7

3, 200 rpm and 10, 000 rpm

Rotor/anode rotations

New cards
8

10, 000 rpm

Anode rotation for high capacity tubes

New cards
9

1-2% thorium

Additional for filament

New cards
10

80%

Maximum exposure limit for single exposure

New cards
11

25s

Intervals between spot films

New cards
12

450kg

Floating tables

New cards
13

150kw (150kvp, 1000mA)

Power rating of stationary radiography unit

New cards
14

1 mGy/hr at 1 m

Limit of scatter radiaion

New cards
15

4 thickness of 5/8 gypsum board

Walls of secondary protective barriers

New cards
16

0.04-320 mAs

MAs for mobile units

New cards
17

40-130 kVp

KVp for mobile units

New cards
18

15-25kw

Power rating for mobile units

New cards
19

Less than 1ms

Solid state detector can measure exposure times at

New cards
20

600mAs greater than or equal to 51kVp

Termination of back up time in AEC

New cards
21

50 to 75 times light photons

Photoelectrons arrives in output phosphor

New cards
22

12, 17, 25 cm

Most popular trifield tubes

New cards
23

2.5 or 5cm

Standard size of output phosphor

New cards
24

10-40cm

Input phosphor size

New cards
25

15mm 25cm

Diameter and length of cylindrical housing of television camera

New cards
26

120 films/hr

First automatic processor could process

New cards
27

40 minutes

Total cycle time for processing film in first automatic processor

New cards
28

10 ft 3 tons

Size of first roller transport system

New cards
29

90 seconds

Dry-to-drop time of rapid processing

New cards
30

45 seconds

Processing cycle time for automatic processor introduced by Konica

New cards
31

1 inch

Diameter of transport rollers

New cards
32

3 inches

Diameter of of master/solar rollers

New cards
33

10-20 rpm

Reduced shaft of drive motor

New cards
34

35*C or 95*F

Temperature of developer

New cards
35

3*C or 5*F

Temperature of wash water

New cards
36

12L/minute or 3gal/minute

Wash water in circulation sytem

New cards
37

60 to 70 ml

Replenishment rate for developer

New cards
38

100 to 110 ml; 14 inches or 35cm of film

Replenishment rate for fixer; for every

New cards
39

3 heating coils and 2, 500w

Used for dryer system

New cards
40

22s

Developing time for automatic processor

New cards
41

22s

Fixing time for automatic processor

New cards
42

26s

Drying time for automatic processor

New cards
43

90s

Total cycle time for automatic processing

New cards
44

15s

Wetting time for manual processing

New cards
45

30s

Rinsing time for manual processing

New cards
46

15min

Fixing time for manual processing

New cards
47

20min

Washing time for manual processing

New cards
48

30min

Drying time for manual processing

New cards
49

1hr 10min 45s

Total cycle time for manual processing

New cards
50

1mm x 4mm = 4mm2

Size of stationary target

New cards
51

15cm diameter, 17cm radius

Size of rotating target

New cards
52

2 PI 70mm x 4mm = 1760mm2

Total target area

New cards
53

3 cassette per second

Maximum exposure rate of ACC

New cards
54

24 to 48 hrs

Maintenance for perfect film-screen radiograph result in fuzzy radioraph

New cards
55

16mm and 35mm

Spot film sizes

New cards
56

100mA (usually 10-40mA)

Exposure factors for conventional tomography

New cards
57

3-6 seconds

Exposure amplitude

New cards
58

5%

Change in kVp for visible exposure difference in image for conventional tomography

New cards
59

100%

Exposure amplitude of narrow angle tomography

New cards
60

1mm solid state cadmium telluride

Size of multiple detector array in BMD

New cards
61

30mm metal brass

Height of detector collimator in BMD

New cards
62

72mm x 8mm metal brass

Size of detector collimator in BMD

New cards
63

18mm x 2.5mm lead

Size of source collimator in BMD

New cards
64

4mm lead

Size of shutter in BMD

New cards
65

35kev, 40;100kev, 40;70kev

Energies of gamma radiation emitted by the xray source in BMD

New cards
66

140kVp-high and 70 to 100kVp-low

Alternating kVp emitted by x-ray generator in BMD

New cards
67

70kev-high and 40kev-low

Separate energy emitted by rare earth filter

New cards
68

Every 3 or 6 months

Periodic maintenance

New cards

Explore top notes

note Note
studied byStudied by 8 people
... ago
5.0(1)
note Note
studied byStudied by 19 people
... ago
5.0(1)
note Note
studied byStudied by 83 people
... ago
5.0(1)
note Note
studied byStudied by 4 people
... ago
5.0(1)
note Note
studied byStudied by 7 people
... ago
5.0(1)
note Note
studied byStudied by 12 people
... ago
5.0(1)
note Note
studied byStudied by 25 people
... ago
5.0(1)
note Note
studied byStudied by 1024 people
... ago
5.0(4)

Explore top flashcards

flashcards Flashcard (32)
studied byStudied by 12 people
... ago
5.0(2)
flashcards Flashcard (38)
studied byStudied by 4 people
... ago
5.0(2)
flashcards Flashcard (49)
studied byStudied by 6 people
... ago
5.0(1)
flashcards Flashcard (71)
studied byStudied by 10 people
... ago
5.0(1)
flashcards Flashcard (64)
studied byStudied by 1 person
... ago
5.0(1)
flashcards Flashcard (20)
studied byStudied by 6 people
... ago
5.0(1)
flashcards Flashcard (26)
studied byStudied by 17 people
... ago
5.0(1)
robot