1/91
Looks like no tags are added yet.
Name | Mastery | Learn | Test | Matching | Spaced | Call with Kai |
|---|
No analytics yet
Send a link to your students to track their progress
c
Who can sign and seal fire prevention plan?
a Sanitary Engineer
b Environmental Engineer
c Professional Mechanical Engineer
d Civil Engineer
c
Who can sign and seal plumbing plan?
a Sanitary Engineer
b Environmental Engineer
c Professional Mechanical Engineer
d Civil Engineer
c
In a complete set, where can you find plumbing, heating and air-conditioning plans and details?
a Plumbing
b Electrical
c Mechanical
d Architectural
d
Fire extinguishers having a gross weight not exceeding eighteen kilogram (18 kg) shall be installed so that the top of the fire extinguisher is not more ______ meters above the floor.
a 1.20
b 1.30
c 1.40
d 1.50
a
Fire extinguishers having a gross weight greater than eighteen kilogram (18 kg), except wheeled types, shall be so installed that the top of the fire extinguisher is not more than _______ meter above the floor.
a 1.00
b 1.20
c 1.50
d 2.00
b
In no case shall the clearance between the bottom of the fire extinguisher and the floor be less than _______ millimeters.
a 76
b 100
c 125
d 150
c
The following types of fire extinguishers are considered obsolete and shall be removed from service except
a soda acid
b chemical foam (excluding film-forming agents)
c Carbon dioxide
d cartridge-operated water
c
The following types of fire extinguishers are considered obsolete and shall be removed from service except
a vaporizing liquid (e.g., carbon tetrachloride)
b chemical foam (excluding film-forming agents)
c Wet chemical foam
d copper or brass shell (excluding pump tanks) joined by soft solder or rivets
c
The best and only recommended way to extinguish a class D fire extinguisher is?
a Water
b Foam
c Dry powder
d Carbon dioxide
b
The best and only recommended way to extinguish a class K fire extinguisher is?
a Water
b Wet Chemical
c Dry powder
d Carbon dioxide
c
The best and only recommended way to extinguish a class C fire extinguisher is?
a Water
b Wet Chemical
c Dry powder
d Foam
d
The not advisable way to extinguish a class A fire extinguisher is?
a Water
b Foam
c Dry powder
d Carbon dioxide
a
What does C represent in the equation?
Q= CiA
a runoff coefficient
b Maximum rate of runoff
c Average rainfall intensity
d Drainage area
c
How many btus are required to heat 10 gallons of water by 10 degrees Fahrenheit at sea level under normal atmospheric conditions?
a 100
b 83.3
c 833
d 10
b
What is the temperature in degree °C of 2 liters of water at 30 degree C after 500 calories of heat have been added to?
a 3.025
b 30.25
c 29.75
d 2.975
d
What is the size of downspout if the rainfall
intensity is 100 mm Ɵ(4”) on a 1200 m² deck roof
a 75 mm
b 100 mm
c 200 mm
d 150 mm
b
What is the size of horizontal rainwater pipe with 2% slope if the max. rainfall is 100 mm on a 206 m².
a 250 mm
b 100 mm
c 300 mm
d 375 mm
d
What is the size of gutter 2 % slope if the max rainfall 150 mm on 120 m²
a 175 mm
b 120 mm
c 200 mm
d 150 mm
b
means an ability to withstand the wear and tear of friction caused by mechanical parts and instances of repetitive scraping or rubbing.
a Corrosion resistance
b Abrasion Resistance
c Mechanical Resistance
d Fire Resistance
a
the property of a piping material that enables it not to wear away by rusting or by the action of chemicals.
a Corrosion resistance
b Abrasion Resistance
c Mechanical Resistance
d Fire Resistance
c
a characteristic of material that causes resistance of liquid to flow.
a Corrosion resistance
b Abrasion Resistance
c Flow Resistance
d Fire Resistance
a
resistance of a material to rupture caused by overpressure of air or liquid inside the pipe.
a Pressure resistance
b Abrasion Resistance
c Overpressure Resistance
d Fire Resistance
d
the capacity of a material or construction to withstand fire or give protection from it.
a Pressure resistance
b Abrasion Resistance
c Overpressure Resistance
d Fire Resistance
c
The attraction of molecules for other molecules of the same kind
a Ideal fluid
b Pilot tube
c Cohesion
d Adhesion
d
The attraction of molecules for other molecules of a different kind
a Ideal fluid
b Pilot tube
c Cohesion
d Adhesion
d
the property of a metal that permits mechanical deformation by extrusion, forging, rolling, etc. without fracturing.
a Elasticity
b Brittleness
c Ductility
d Malleability
a
the resistance of a material to deformation by compression or indentation.
a Hardness
b Brittleness
c Ductility
d Malleability
d
the property of a material which fractures under low stress without appreciable deformation.
a Elasticity
b Brittleness
c Ductility
d Malleability
c
property of a material described as capable of being stretched or deformed without fracturing.
a Elasticity
b Brittleness
c Ductility
d Malleability
a
property of a material that enables it to deform in
response to an applied force and to recover its original size and shape upon removal of the force.
a Elasticity
b Brittleness
c Ductility
d Malleability
a
This standard provides requirements for fire protection of telecommunications facilities
a NFPA 76
b NFPA 3
c NFPA 75
d NFPA 14
d
This standard provides requirements for the Installation of Sprinkler Systems
a NFPA 76
b NFPA 3
c NFPA 75
d NFPA 14
b
This standard provides requirements for Portable Fire Extinguishers
a NFPA 76
b NFPA 10
c NFPA 75
d NFPA 14
c
This standard provides requirements for the Fire Protection of Information Technology Equipment
a NFPA 76
b NFPA 10
c NFPA 75
d NFPA 14
a
This standard provides requirements for the Fire Code
a NFPA 1
b NFPA 2
c NFPA 3
d NFPA 4
c
This standard provides requirements for Commissioning of Fire Protection and Line Safety Systems
a NFPA 1
b NFPA 2
c NFPA 3
d NFPA 4
c
This standard provides requirements for the Installation of Air-conditioning and Ventilating Systems
a NFPA 75
b NFPA 76
c NFPA 90A
d NFPA 90B
d
This standard provides requirements for the Installation of Warm Air Heating and Air-conditioning Systems
a NFPA 75
b NFPA 76
c NFPA 90A
d NFPA 90B
b
The minimum diameter of a dry standpipe requiring a 2-way Siamese connection is_____. (National Building Code, PD 1096)
a 76 mm
b 100 mm
c 125 mm
d 150 mm
c
The minimum diameter of a dry standpipe requiring a 3-way Siamese connection is_____. (National Building Code, PD 1096)
a 76 mm
b 100 mm
c 125 mm
d 150 mm
d
The minimum diameter of a dry standpipe requiring a 4-way Siamese connection is_____. (National Building Code, PD 1096)
a 76 mm
b 100 mm
c 125 mm
d 150 mm
b
A red spiral line painted on a pipe section identified the pipe as
a Cast Iron pipe
b Wrought iron pipe
c Copper pipe
d Brass pipe
d
A brewery plant requires a piping system to convey beer, ale, spirituous liquor and distilled water. What kind of pipe to be used?
a Cast Iron pipe
b Wrought iron pipe
c Copper pipe
d Black tin pipe
What should be the hanger rod size (inches) for a pipe ranging 5 to 8 inches diameter
a 3/8
b 1/2
c 5/8
d 3/4
What should be the hanger rod size (inches) for a pipe ranging 1/2 to 4 inches diameter
a 3/8
b 1/2
c 5/8
d 3/4
What should be the hanger rod size (inches) for a pipe ranging 10-12 inches diameter
a 3/8
b 1/2
c 5/8
d 3/4
Each standpipe shall be provided with a means of draining. What should be size of drain connection (inches) for standpipe size up to 2 inches
a 3/8 or larger
b 3/4 or larger
c 1 1/4 or larger
d 2 only
Each standpipe shall be provided with a means of draining. What should be size of drain connection (inches) for standpipe size 2 1/2 inches to 3 1/2 inches
a 3/8 or larger
b 3/4 or larger
c 1 1/4 or larger
d 2 only
Each standpipe shall be provided with a means of draining. What should be size of drain connection (inches) for standpipe size 4 inches or larger
a 3/8 or larger
b 3/4 or larger
c 1 1/4 or larger
d 2 only
Each standpipe shall be provided with a means of draining. What should be size of drain connection (inches) for standpipe size 4 inches or larger
a 3/8 or larger
b 3/4 or larger
c 1 1/4 or larger
d 2 only
What is the minimum septic tank capacity in liters for Single Family Dwelling with 1 or 2 Bedrooms?
a 2838
b 3785
c 4542
d 5677.5
What is the minimum septic tank capacity in liters for Single Family Dwelling with 3 Bedrooms?
a 2838
b 3785
c 4542
d 5677.5
What is the minimum septic tank capacity in liters for Apartment with 2 units?
a 2838
b 3785
c 4542
d 5677.5
What is the maximum working pressure (kPa) of a Schedule 40 1 inch diameter
a 2170.4
b 2204.8
c 1515.8
d 1162.4
What is the maximum working pressure (kPa) of a Schedule 40 3 inch diameter
a 2170.4
b 2204.8
c 1515.8
d 1162.4
What is the maximum working pressure (kPa) of a Schedule 40 6 inch diameter
2170.4
2204.8
1515.8
1162.4
What is the acronym SDR stands for?
a Standard Data Release
b Stop, Drop and Roll
c Supply Demand Review
d Standard Dimension Ratio
How many water closets are required for a Secondary School with 2000 Male students
a 100
b 80
c 67
d 50
How many water closets are required for a Secondary School with 2000 Female students
a 100
b 80
c 67
d 50
How many urinals are required for a Secondary School with 2000 male students
a 27
b 58
c 67
d 50
What is safe bearing load of a soft clay soil?
a 6890 kPa
b 13780 kPa
c 20670 kPa
d 27360 kPa
What is safe bearing load of a sand soil?
a 6890 kPa
b 13780 kPa
c 20670 kPa
d 27360 kPa
What is safe bearing load of a sand and gravel soil?
a 6890 kPa
b 13780 kPa
c 20670 kPa
d 27360 kPa
Assume a 1780 kN total thrust was computed and soil condition is sand. Compute the required bearing area of the thrust block
a 0.258 sqm
b 0.129 sqm
c 0.086 sqm
d 0.065 sqm
In the figure below, identify "A"
a Flanged Elbow - Side Outlet (Outlet Up)
b Flanged Elbow - Side Outlet (Outlet Down)
c Screwed Elbow - Side Outlet (Outlet Up)
d Screwed Elbow - Side Outlet (Outlet Down)
In the figure below, identify "B"
a Flanged Elbow - Side Outlet (Outlet Up)
b Flanged Elbow - Side Outlet (Outlet Down)
c Screwed Elbow - Side Outlet (Outlet Up)
d Screwed Elbow - Side Outlet (Outlet Down)
In the figure below, identify "A"
a Flanged Plug Bull
b Screwed Plug Bull
c Flanged Reducing Flange
d Screwed Reducing Flange
In the figure below, identify "B"
a Flanged Plug Bull
b Screwed Plug Bull
c Flanged Reducing Flange
d Screwed Reducing Flange
Figure shown is the parts of trap, identify "B"
a Trap Adapter
b Tail Piece
c Trap Arm
d Trap weir
Figure shown is the parts of trap, identify "G"
a Trap Adapter
b Trap Dip
c Trap Arm
d Trap weir
Figure shown is the parts of trap, identify "I"
a Outlet
b Trap Dip
c Trap Arm
d Trap weir
Figure shown is different types of lavatory , identify "A"
a Dental Lavatory
b Pedestal lavatory
c Wall lavatory
d Handicapped lavatory
Figure shown is different types of lavatory , identify "B"
a Dental Lavatory
b Pedestal lavatory
c Wall lavatory
d Handicapped lavatory
Figure shown is different types of lavatory , identify "E"
Dental Lavatory
Pedestal lavatory
Wall lavatory
Handicapped lavatory
Figure shown is different types of water closet, identify "A"
WC (Integral tank)
WC (Tank type)
WC (Flush valve, wall-hung)
WC (Flush valve, floor outlet)
Figure shown is different types of water closet, identify "B"
WC (Integral tank)
WC (Tank type)
WC (Flush valve, wall-hung)
WC (Flush valve, floor outlet)
Figure shown is different types of water closet, identify "C"
WC (Integral tank)
WC (Tank type)
WC (Flush valve, wall-hung)
WC (Flush valve, floor outlet)
Hose connections and hose stations shall be unobstructed and shall be located not less than ____ above the floor.
1.20 m
1.0 m
0.90 m
0.80 m
Hose connections and hose stations shall be unobstructed and shall be located not more than ____ above the floor.
1.60 m
1.50 m
1.40 m
1.20 m
Class II hose length shall not be more than ____
30.0 m
30.5 m
23.0 m
22.0 m
Where using 1" hose, a listed ______ hose shall be used.
lined
nonlined
collapsible
non-collapsible
Where using 11∕2 in. hose, it shall be equipped with a listed ____ or approved storage method.
cabinet
rack
box
support
The minimum flow rate for the hydraulically most remote Class II hose connection shall be ____ gpm.
90
100
110
120
Hydraulically designed standpipe systems shall be designed to provide the waterflow rate of 100 gpm at a minimum residual pressure of ___ at the outlet of the hydraulically most remote class II hose connection.
65 psi
75 psi
80 psi
85 psi
What is the required slope for all sprinkler pipe and fittings shall be installed so that the system can be drained?
1 %
1.5 %
2 %
2.5 %
A beginner at the trade who usually serves for 3 to 5 years as a helper to a journeyman.
Apprentice plumber
Intern Plumber
OJT Plumber
Practicing Plumber
has served his apprenticeship and is competent to perform the tasks of installing and repairing the plumbing system.
Apprentice plumber
Master Plumber
Journeyman Plumber
Pipeman
a person technically and legally qualified and licensed to practice the profession of master plumbing without limitations in accordance with R.A. 1378, having passed the examinations conducted by the Professional Regulation Commission, has received a Certificate of Registration from the Board of Master Plumbing and possesses the current License to Practice. (Sec. 214.5 NPC 1999)
Apprentice plumber
Master Plumber
Journeyman Plumber
Pipeman
In the figure shown, identify "B"
Globe Valve
Gate Valve
Check Valve
Meter
In the figure shown, identify "K"
Globe Valve
Gate Valve
Check Valve
Meter
In the figure shown, identify "F"
Globe Valve
Gate Valve
Check Valve
Meter
In the figure shown, identify "J"
Reducer
Coupling
Transition piece
Flanged Joint