1/21
Flashcards covering architectural design considerations, building classifications, height limits, setbacks, accessibility laws (BP 344), and the architectural design process based on the DPWH training transcript.
Name | Mastery | Learn | Test | Matching | Spaced | Call with Kai | Chat |
|---|
No analytics yet
Send a link to your students to track their progress
Architectural design is the process of shaping spaces and structures to meet human needs while achieving beauty, ________, and purpose.
stability
The 2018 edition of the ________ of the Philippines (P.D. 1096) is a primary reference code for architectural designers.
National Building Code
The law known as the Accessibility Law, which enhances the mobility of disabled persons, is ________.
Batas Pambansa Bilang 344
The Act known as the Comprehensive Fire Code of the Philippines is ________.
RA 9514
According to NBCP Rule VII, Group ________ buildings are classified as Residential Dwellings used for sleeping or living purposes.
A
Group ________ buildings are used for transient accommodation, such as hotels and apartments.
B
Institutional buildings categorized as Group ________ include facilities for care, medical treatment, or detention where occupants need supervision.
D
Group E buildings are used for ________ and Mercantile purposes, such as the transaction of business or sale of merchandise.
Business
Buildings used for the fabrication, assembly, or processing of materials are classified as Group ________.
F
Assembly buildings with an occupant load of ________ or more are classified as Group H.
1000
For commercial buildings with a Road Right of Way (RROW) of 30.00m and above, the required front setback is ________.
8.00m
The Building Height Limit (BHL) for a Residential 1 (R−1) structure is ________.
10.00m
A Commercial 3 (C−3) building has a Building Height Limit ranging from 16 to 60 storeys or ________.
48.00−180.00m
In the 2024 amendments to the IRR of BP344, ________ nosings are preferred for stairs.
Slanted
If a parking lot has a total of 51-75 slots, the required number of accessible PWD parking slots is ________.
3
A PWD ramp must have a maximum gradient of ________ to meet design regulations.
1:20
Handrails on PWD ramps must be installed on both sides at heights of ________ and ________ from the finish ramp level.
900mm and 700mm
The minimum turning space required for a PWD water closet stall is ________.
1.50×1.50m
Before starting project plans, proof of land ownership such as a ________ or a Notarized MOA must be established.
Transfer Certificate of Title
The ________ phase of the architectural design process includes activities such as preliminary site analysis.
Pre-Design
The ________ phase involves bubble diagrams and initial zoning of space and functions.
Schematic Design
Coordination between the architect, civil engineer, electrical engineer, and other specialists occurs during the ________ phase.
Design Development