International Organization for Standards
ISO stands for _________
International Union of Pure and Applied Chemistry
IUPAC stands for _________
Clinical and Laboratory Standards Institute
CLSI stands for _________
Substance Abuse and Mental Health Services Administration
SAMHSA stands for _________
SAMHSA
Certifies laboratories to conduct forensic drug testing for federal agencies
Liter
Is used as a reference volume
Katal or U/L
SI Unit for enzyme
Meter
SI unit for length
Kilogram
SI unit for Mass
Second
SI unit for time
Ampere
SI unit for Electric current
Kelvin
SI unit for Thermodynamic temperature
Mole
SI unit for amount of substance
Candela
SI unit for luminous intensity
Frequency
SI unit for Hertz
Newton
SI unit for Force
Degrees Celsius
SI unit for Celsius temperature
Celsius
The predominant practice for temperature measurement uses the __________
Katal
SI unit for Catalytic activity
°F = (°C x 1.8) + 32
Formula for Fahrenheit
°C = (°F - 32) x 0.556
Formula for Celsius
10-18
Scientific notation for Atto
10-15
Scientific notation for Femto
10-12
Scientific notation for Pico
10-9
Scientific Notation for Nano
10-6
Scientific notation for Micro
10-3
Scientific notation for Milli
10-2
Scientific notation for Centi
10-1
Scientific notation for Deci
10
Conversion factor for Albumin and Total Protein
17.1
Conversion factor for Bilirubin
0.357
Conversion factor for BUN
1.0
Conversion factor for Na, K, Cl
0.25
Conversion factor for Calcium
0.026
Conversion factor for Cholesterol
88.4
Conversion factor for Creatinine
0.0555
Conversion factor for Glucose
12.9
Conversion factor for Thyroxine
0.0113
Conversion factor for TAG
0.0595
Conversion factor for Uric Acid
10
Conversion factor for Hb
0.133
Conversion factor for pCO2 and pO2
0.587
Conversion factor for Ammonia
0.276
Conversion factor for Cortisol
2.27
Conversion factor for Folic acid
400-700 nm
Visible spectrum
Ultraviolet region
What region if <400 nm?
Infrared region
What region if >700 nm?
greater
The shorter the wavelength, the ________ the energy
400-500 nm
Red color absorbs ________ nm of light and transmits light of 600-650 nm
525 nm
A green colored-solution would show highest transmittance at _______
inversely
Wavelength is ________ proportional to frequency
directly
Frequency is _________ proportional to energy
Red
Violet or Red: Which has longer wavelength?
Gamma
Gamma or Microwaves: Which has higher energy?
Tungsten Light Bulb
Most commonly used light
Hollow Cathode Lamp
Light used in AAS
Deuterium discharge lamp and Mercury Arc Lamp
Most commonly used lamp for UV sources
Entrance Slit
Minimizes unwanted stray light
Stray Light
Is the most common cause of loss of linerarity
Second-Order Spectra
Most common cause of stray light
Absorbance error
Major effect of stray light
Sharp cut-off filters
Type of filter best for measuring stray light
Neutral Density Filter and Dichromate Solution
It verifies absorbance accuracy on linearity
Monochromator
Isolates specific wavelength of light
Diffraction Grating
Most common used monochroator
Prism
Monochromator that has the purest light in UV range
Didymium or Holmium Oxide Filter
Is used for verifying wavelength accuracy
Exit slit
Controls the bandpass/ bandwidth
greater
The narrower the bandpass, the ________ the photometric solution
Cuvet
Also called absorption cell/ analytical cell/ sample cell. It holds the solution.
Square cuvette
Has advantage over round cuvette
Discard
What will you do is there is scratched to optical surfaces?
Alumina silica
Most commonly used cuvette
Glass cuvettes
Cuvettes used for visible range but absorbs UV
Quartz Cuvette
Cuvettes for UV radiation
directly
In Beer’s Law, unknown substance is________ proportional to absorbed light.
Inversely
In Beer’s Law, unknown substance is________ proportional to transmitted light.
molar absorptivity
the a in A= abc represents the
path length
the b in A= abc represents the
concentration
the c in A= abc represents the
Photodetector
Detects and converts transmitted light to electricity
Photomultiplier tube
Most common type, has excellent sensitivity type of photodetector
Photovoltaic cell/ Barrier layer cell/ Photocell
Simplest detector, required no external voltage source
Photodiode
A photodetector that respond to a specific wavelength UV/ Visible
Reagent blank
It corrects for absorbance caused by the color of the reagent
100
0 absorbance = ____ transmittance
chromogens or lipemia
Reagent blank has no correction for interfering _______________
Ultracentrifugation
Used to clear the serum of plasma of chylomicrons
Saline
Sample blank is performed by substituting the _____ for reagent
inverse
In reflectometry, the intensity of light is _______ in relation to the concentration of the analyte.
opaque
100% reflectance is set with an ________ film called a white reference
Reflectometry
Principle used in Bilirubinometer and Automated Reagent Strip Reader
Flame Emission Photometry
Measure the light emitted by a single atom burned in a flame
Blue
Hottest color
yellow
Color of Sodium in FEP
violet
color of potassium in FEP
red
color of lithium and rubidium in FEP
blue
color of magnesium/ copper
AAS
Principle employed for the measurement Ca and Mg