154 Terms

1
New cards

International Organization for Standards

ISO stands for _________

2
New cards

International Union of Pure and Applied Chemistry

IUPAC stands for _________

3
New cards

Clinical and Laboratory Standards Institute

CLSI stands for _________

4
New cards

Substance Abuse and Mental Health Services Administration

SAMHSA stands for _________

5
New cards

SAMHSA

Certifies laboratories to conduct forensic drug testing for federal agencies

6
New cards

Liter

Is used as a reference volume

7
New cards

Katal or U/L

SI Unit for enzyme

8
New cards

Meter

SI unit for length

9
New cards

Kilogram

SI unit for Mass

10
New cards

Second

SI unit for time

11
New cards

Ampere

SI unit for Electric current

12
New cards

Kelvin

SI unit for Thermodynamic temperature

13
New cards

Mole

SI unit for amount of substance

14
New cards

Candela

SI unit for luminous intensity

15
New cards

Frequency

SI unit for Hertz

16
New cards

Newton

SI unit for Force

17
New cards

Degrees Celsius

SI unit for Celsius temperature

18
New cards

Celsius

The predominant practice for temperature measurement uses the __________

19
New cards

Katal

SI unit for Catalytic activity

20
New cards

°F = (°C x 1.8) + 32

Formula for Fahrenheit

21
New cards

°C = (°F - 32) x 0.556

Formula for Celsius

22
New cards

10-18

Scientific notation for Atto

23
New cards

10-15

Scientific notation for Femto

24
New cards

10-12

Scientific notation for Pico

25
New cards

10-9

Scientific Notation for Nano

26
New cards

10-6

Scientific notation for Micro

27
New cards

10-3

Scientific notation for Milli

28
New cards

10-2

Scientific notation for Centi

29
New cards

10-1

Scientific notation for Deci

30
New cards

10

Conversion factor for Albumin and Total Protein

31
New cards

17.1

Conversion factor for Bilirubin

32
New cards

0.357

Conversion factor for BUN

33
New cards

1.0

Conversion factor for Na, K, Cl

34
New cards

0.25

Conversion factor for Calcium

35
New cards

0.026

Conversion factor for Cholesterol

36
New cards

88.4

Conversion factor for Creatinine

37
New cards

0.0555

Conversion factor for Glucose

38
New cards

12.9

Conversion factor for Thyroxine

39
New cards

0.0113

Conversion factor for TAG

40
New cards

0.0595

Conversion factor for Uric Acid

41
New cards

10

Conversion factor for Hb

42
New cards

0.133

Conversion factor for pCO2 and pO2

43
New cards

0.587

Conversion factor for Ammonia

44
New cards

0.276

Conversion factor for Cortisol

45
New cards

2.27

Conversion factor for Folic acid

46
New cards

400-700 nm

Visible spectrum

47
New cards

Ultraviolet region

What region if <400 nm?

48
New cards

Infrared region

What region if >700 nm?

49
New cards

greater

The shorter the wavelength, the ________ the energy

50
New cards

400-500 nm

Red color absorbs ________ nm of light and transmits light of 600-650 nm

51
New cards

525 nm

A green colored-solution would show highest transmittance at _______

52
New cards

inversely

Wavelength is ________ proportional to frequency

53
New cards

directly

Frequency is _________ proportional to energy

54
New cards

Red

Violet or Red: Which has longer wavelength?

55
New cards

Gamma

Gamma or Microwaves: Which has higher energy?

56
New cards

Tungsten Light Bulb

Most commonly used light

57
New cards

Hollow Cathode Lamp

Light used in AAS

58
New cards

Deuterium discharge lamp and Mercury Arc Lamp

Most commonly used lamp for UV sources

59
New cards

Entrance Slit

Minimizes unwanted stray light

60
New cards

Stray Light

Is the most common cause of loss of linerarity

61
New cards

Second-Order Spectra

Most common cause of stray light

62
New cards

Absorbance error

Major effect of stray light

63
New cards

Sharp cut-off filters

Type of filter best for measuring stray light

64
New cards

Neutral Density Filter and Dichromate Solution

It verifies absorbance accuracy on linearity

65
New cards

Monochromator

Isolates specific wavelength of light

66
New cards

Diffraction Grating

Most common used monochroator

67
New cards

Prism

Monochromator that has the purest light in UV range

68
New cards

Didymium or Holmium Oxide Filter

Is used for verifying wavelength accuracy

69
New cards

Exit slit

Controls the bandpass/ bandwidth

70
New cards

greater

The narrower the bandpass, the ________ the photometric solution

71
New cards

Cuvet

Also called absorption cell/ analytical cell/ sample cell. It holds the solution.

72
New cards

Square cuvette

Has advantage over round cuvette

73
New cards

Discard

What will you do is there is scratched to optical surfaces?

74
New cards

Alumina silica

Most commonly used cuvette

75
New cards

Glass cuvettes

Cuvettes used for visible range but absorbs UV

76
New cards

Quartz Cuvette

Cuvettes for UV radiation

77
New cards

directly

In Beer’s Law, unknown substance is________ proportional to absorbed light.

78
New cards

Inversely

In Beer’s Law, unknown substance is________ proportional to transmitted light.

79
New cards

molar absorptivity

the a in A= abc represents the

80
New cards

path length

the b in A= abc represents the

81
New cards

concentration

the c in A= abc represents the

82
New cards

Photodetector

Detects and converts transmitted light to electricity

83
New cards

Photomultiplier tube

Most common type, has excellent sensitivity type of photodetector

84
New cards

Photovoltaic cell/ Barrier layer cell/ Photocell

Simplest detector, required no external voltage source

85
New cards

Photodiode

A photodetector that respond to a specific wavelength UV/ Visible

86
New cards

Reagent blank

It corrects for absorbance caused by the color of the reagent

87
New cards

100

0 absorbance = ____ transmittance

88
New cards

chromogens or lipemia

Reagent blank has no correction for interfering _______________

89
New cards

Ultracentrifugation

Used to clear the serum of plasma of chylomicrons

90
New cards

Saline

Sample blank is performed by substituting the _____ for reagent

91
New cards

inverse

In reflectometry, the intensity of light is _______ in relation to the concentration of the analyte.

92
New cards

opaque

100% reflectance is set with an ________ film called a white reference

93
New cards

Reflectometry

Principle used in Bilirubinometer and Automated Reagent Strip Reader

94
New cards

Flame Emission Photometry

Measure the light emitted by a single atom burned in a flame

95
New cards

Blue

Hottest color

96
New cards

yellow

Color of Sodium in FEP

97
New cards

violet

color of potassium in FEP

98
New cards

red

color of lithium and rubidium in FEP

99
New cards

blue

color of magnesium/ copper

100
New cards

AAS

Principle employed for the measurement Ca and Mg