Machine Foundation Mass (Vibration Dampening)

Foundation mass that should be 10 to 20 times the weight of the machinery it is supposed to support if the unbalance forces produced by the machine can be calculated to dampen vibration.

2
New cards

Foundation Perimeter Isolation Distance

The distance of 25mm25\,\text{mm} around the perimeter of a machine foundation used to isolate it from floor slabs or building footings and eliminate transmission of vibration.

3
New cards

Foundation Bolt Pipe Sleeve Diameter

An inside diameter of a pipe sleeve surrounding foundation bolts that is at least 3 times the diameter of the anchor bolt.

4
New cards

Flooded refrigeration system

A refrigeration system in which only part of the refrigerant passing over the heat transfer is separated from the vapor and recirculated.

5
New cards

Comfortable Cooling Relative Humidity

Effective relative humidity of air maintained at 50% to 60% for comfortable cooling.

6
New cards

Ammonia Water Tank Ratio

Requirement of at least 1 liter of water for every 120 gallons of ammonia, used exclusively for ammonia absorption upon discharge.

7
New cards

Window Air Conditioner Exhaust Duct Height

Installation height of not less than 2.10m2.10\,\text{m} above floor level when exhaust ducts discharge into corridors, hallways, arcades, or sidewalks.

8
New cards

Refrigerating Plant Helmet/Mask Requirement

Safety equipment required for refrigerating plants rated for more than 35kg35\,\text{kg}.

9
New cards

Machine Room Refrigerant Storage Limit

Up to 140kilograms140\,\text{kilograms} of refrigerant stored in approved containers in a machine room at any given time.

10
New cards

Refrigeration Machinery Room Walking Space Width

An unobstructed walking space of at least 3feet3\,\text{feet} in width.

11
New cards

Refrigeration Machinery Room Walking Space Height

An unobstructed walking space of at least 6ft and 8inches6\,\text{ft and } 8\,\text{inches} in height.

12
New cards

Clean agent

Electrically non-conducting volatile or gaseous fire extinguisher that does not leave residue upon evaporation.

13
New cards

Permanent gravity ventilation openings

Openings having not less than 2sq.ft.2\,\text{sq.ft.} net free area opening directly to the outside of the building or extending by continuous duct.

14
New cards

Occupancy Ventilation Duct Temperature Limit

Ducting used for conveying air at temperatures not exceeding 150C150\,^{\circ}\text{C} through other than heating or air conditioning systems.

15
New cards

Natural Ventilation Wall Opening Ratio

Minimum permanent wall opening equal to 4% of the net occupied area for spaces provided with natural ventilation.

16
New cards

Meeting Room Outdoor Air Rate Requirement

620cfm620\,\text{cfm} required for a single zone AC unit serving an interior 2000sq.ft.2000\,\text{sq.ft.} meeting/conference room with 100 people and ceiling supply and return.

17
New cards

Liquid receiver

A vessel permanently connected to a system by inlet and outlet pipes for storage of liquid refrigerant.

18
New cards

Stop valve

A shut-off valve other than a valve for controlling the flow of refrigerant.

19
New cards

Absorption refrigeration system

A refrigeration system in which the refrigerant gas evolved in the evaporator is taken up in an absorber and released in a generator upon the application of heat.

20
New cards

Comfort Cooling Temperature Standard

Temperature of air maintained at 2023.3C20 - 23.3\,^{\circ}\text{C} for comfort cooling.

21
New cards

Comfort Cooling Relative Humidity Standard

Air humidity maintained at 55% to 60% relative humidity for comfort cooling.

22
New cards

Refrigerant Piping Open Space Clearance

Clearance height of not less than 2290mm2290\,\text{mm} above the floor when crossing an open space that affords passageway in a building.

23
New cards

Refrigerant Charging Side

The low pressure side of the system where refrigerant is added.

24
New cards

Cascade refrigeration system

A refrigeration system having two or more refrigerant circuits, each with a pressure-imposing element, condenser, and evaporator, where the evaporator of one circuit cools the condenser of another circuit.

25
New cards

Refrigerant

A substance which produces a refrigerating effect by its absorption of heat while expanding or evaporating.

26
New cards

Brine

Any liquid cooled by the refrigerant and used for the transmission of heat without a change in its state.

27
New cards

Refrigerant 12 Chemical Name

Dichlorodifluoromethane.

28
New cards

Ammonia Chemical Symbol

NH3\text{NH}_3

29
New cards

Freon 12 Chemical Symbol

CCl2F2\text{CCl}_2\text{F}_2

30
New cards

Condensate Drain Pipe Size

At least 19mm19\,\text{mm} nominal pipe size made of copper, galvanized steel, or other corrosion-resistant material.

31
New cards

Chilled water system

An indirect refrigerating system employing water as the circulating system.

32
New cards

Humidity

The ratio of the actual weight of moisture to the weight of saturated water vapor of mixture.

33
New cards

Condenser

A vessel in which vaporized refrigerant is liquefied by the removal of heat.

34
New cards

Humeter