___ is defined as the degree of geometric sharpness or accuracy of structural lines actually recorded in the image.

All of these are correct

3 multiple choice options

2
New cards

The ___ the matrix, the ___ the detail.

greater, greater

3 multiple choice options

3
New cards

(T/F) Unlike film-screen systems, there is no correlation between exposure level and spatial resolution.

True

4
New cards

The cassette-based system, in digital radiography uses a ___ imaging plate inside a cassette.

Photostimulable storage phosphor

3 multiple choice options

5
New cards

Direct acquisition digital radiography directly converts incoming x-rays into a(n) ___

electronic signal

3 multiple choice options

6
New cards

Indirect acquisition digital radiography uses a two-part process involving a scintillator and a photodetector. This system converts x-rays to ___ first.

Light

3 multiple choice options

7
New cards

A ___ converts incoming x-ray photons to light in an indirect system.

Scintillator

3 multiple choice options

8
New cards

The ____ is/are an indicator of potential "speed class" or is a measure of x-ray absorption efficiency.

DQE

3 multiple choice options

9
New cards

Higher DQE means that you have ___ patient dose.

lower

3 multiple choice options

10
New cards

As speed class or DQE decreases, the patient exposure increases while the likelihood of noise _____.

decreases

3 multiple choice options

11
New cards

characteristics affecting the spatial resolution for cassette-based systems include:

All of these

3 multiple choice options

12
New cards

___________refers to an image receptor's ability to respond to different exposure levels or the amount of error for optimal image acquisition.

Dynamic Range

3 multiple choice options

13
New cards

With digital imaging, an underexposure of 50% or greater results in a ____.

mottled image AND

image with noise

3 multiple choice options

14
New cards

The latent image loses about ___% of its energy in approximately 8 hours.

25%

3 multiple choice options

15
New cards

(T/F) With digital imaging, a radiograph does not have to adhere to the same rules of positioning as with film-screen systems. ( Histogram analysis and rescaling will fix it)

False

16
New cards

Misalignment may cause a ___ analysis error leading to incorrect exposure indicators.

Histogram

3 multiple choice options

17
New cards

(T/F) Digital radiography systems allows for much greater exposure range and have extremely low tolerance for patient overexposure.

False

18
New cards

A light guide Assembly:

All of these

3 multiple choice options

19
New cards

These are the two types of plate scanning mechanics:

Line scan and flying spot scan

3 multiple choice options

20
New cards

The DAP meter does the following 3 things EXCEPT

indicates the amount of exposure delivered to the image receptor

3 multiple choice options

21
New cards

Problems with Dose Area Product Meters include:

All of these are correct

3 multiple choice options

22
New cards

This replaces the visual cues of density and contrast that are used in analog imaging systems.

Exposure indicators

3 multiple choice options

23
New cards

Carestream uses an exposure index (EI) that is directly related to exposure and has a logarithmic component. Doubling the exposure would increase the (EI) by:

300

3 multiple choice options

24
New cards

This (vendor) brand of digital imaging system uses the logarithm of a histogram median or LogMean (LgM for their exposure indicators.

AgFa

3 multiple choice options

25
New cards

This/these vendor(s) utilize an S number for their exposure indicators.

Fuji & Phillips

3 multiple choice options

26
New cards

T/F: Inappropriate collimation or beam alignment can result in both histogram analysis error & rescaling error

True

27
New cards

Prior to image creation, the exposure values extracted from the PSP are subject to a process known as:

quantization

3 multiple choice options

28
New cards

_______ graphically represents a collection of exposure values extracted from the receptor.

histograms

3 multiple choice options

29
New cards

Each of the following are formats in which histograms can be analyzed EXCEPT:

photo histogram analysis

3 multiple choice options

30
New cards

With Priori Histogram Analysis, where does the standardized data set come from?

experiments of like subjects under ideal conditions

3 multiple choice options

31
New cards

Examples of histogram analysis errors:

incorrect anatomic menu selection, exposure field not detected, unexpected material in data set, inappropriate rescaling

32
New cards

The predetermined values used to create the image are known as:

the values of interest

3 multiple choice options

33
New cards

Imaging plates unused for more than _____ hours should be erased.

48

3 multiple choice options

34
New cards

What are some ways of reducing scatter?

beam limiting, use of optimal exposures, grid use, use of compression band

35
New cards

What is/are examples of beam-limiting device(s)?

All of these are correct

3 multiple choice options

36
New cards

_______ is one of the principle factors affecting the amount of scatter radiation produced?

kVp

3 multiple choice options

37
New cards

T/F: changes in kVp will not greatly affect radiographic contrast like it did with analog film-screen combos?

True

38
New cards

The Moire Effect may occur when:

All of these are correct

3 multiple choice options

39
New cards

the process of matching the captured image values to a standardized set of values is called:

automatic rescaling

3 multiple choice options

40
New cards

______ describes the concept of density as it is displayed on a soft-copy monitor.

brightness

3 multiple choice options

41
New cards

Increased _________ is considered one of the major advantages of digital receptors, and tends to counteract the lower spatial resolution of man digital imaging systems

contrast resolution

3 multiple choice options

42
New cards

smoothing is included under this type of digitized image filtering category:

low-pass filtering

3 multiple choice options

43
New cards

T/F: high-pass filtering either amplifies or deletes all but the high frequencies

true

44
New cards

T/F: Smoothing will NOT improve edge visibility

true

45
New cards

Low-pass filtering amplifies or deletes all but the ___ frequencies

low

3 multiple choice options

46
New cards

______ is a software function that reduces the appearance of noise in the image.

smoothing

3 multiple choice options

47
New cards

high-pass filtering also referred to as _________.

edge enhancement

3 multiple choice options

48
New cards

This type of artifact, associated with edge enhancement, can mimic a pathological condition & lead to improper diagnosis.

halo artifact

3 multiple choice options

49
New cards

________ is a software function designed to even out the brightness displayed in an image.

equalization

3 multiple choice options

50
New cards

excessive equalization can cause:

degradation of digital image

3 multiple choice options

51
New cards

________ is an indicator of the potential "speed class" or a measure of x-ray absorption efficiency.

DQE

3 multiple choice options

52
New cards

Ways at reducing scatter radiation include:

All of these reduce scatter

3 multiple choice options

53
New cards

T/F: digital radiography is mAs driven

false

54
New cards

T/F: there is no need to collimate with digital imaging systems

false

55
New cards

T/F: magnification no longer occurs with digital imaging systems meaning SID and OID no longer matter.

false

56
New cards

T/F: digital systems are more sensitive to fogging by scatter and/or background radiation than analog film-screen systems

true

57
New cards

T/F: fluorescent lights do not fog PSP plates.

true

58
New cards

T/F: automatic rescaling forces a technologist to look elsewhere for signs that a proper exposure was used to produce an image.

true

59
New cards

_______ refers to the potential to gradually increase patient dose over time.

dose creep

3 multiple choice options

60
New cards

What is the evaluation of digital images based on? *

image blur, exposure indicator, brightness, image noise

61
New cards

this replaces the visual cues of density and contrast that are normally used in analog imaging systems.

exposure indicator

3 multiple choice options

62
New cards

Overexposure greater than __________% results in a loss of image contrast

100-200%

3 multiple choice options

63
New cards

What four things are image brightness and contrast in a digital image affected by? *

1. exposure field recognition

2. grid cutoff

3. off focus radiation

4. wrong menu selection

64
New cards

Image _______ is the difference between adjacent densities

contrast

3 multiple choice options

65
New cards

this term describes the concept of contrast as it is displaced on a soft-copy monitor for digital images.

dynamic range

3 multiple choice options

66
New cards

Other terms used to describe spatial resolution include the following EXCEPT:

dynamic range

3 multiple choice options

67
New cards

What are the three types of motion found with digital imaging?

1. voluntary patient motion

2. involuntary patient motion

3. equipment motion

68
New cards

Blur can be caused by two things, motion and ______.

changes in geometric factors

3 multiple choice options

69
New cards

____________ is the misrepresentation of the size or shape of the structures being examined.

distortion

3 multiple choice options

70
New cards

T/F: with digital imaging, magnification is the only type of size distortion

false

71
New cards

T/F: Quantum noise in digital images is cause by insufficient signal strength.

True

72
New cards

T/F: factors affecting shape distortion include SID and/or OID

false

73
New cards

T/F: artifacts in digital imaging be grouped by image receptor type or by the origin of artifact

True

74
New cards

T/F: Processing artifacts, caused by a dirty light guide in the plate reader, can be best described in that the line (artifact) usually runs the entire length of the plate and is parallel to the direction the plate travels through the reader.

true

75
New cards

T/F: a DEL artifact can be fixed by replacing an individual DEL or row of DEL's

false

76
New cards

the three main types of acceptance testing include the following EXCEPT:

dark noise evaluation

3 multiple choice options

77
New cards

T/F: excessive dark noise degrades the digital image

true

78
New cards

With digital imaging and image brightness uniformity, a ______% variation in pixel value is allowed.

10%

3 multiple choice options

79
New cards

this test assesses exposure levels and the relative change in pixel density

linearity and slope

3 multiple choice options

80
New cards

T/F: the laser beam function test could be used to evaluate "jitter".

true

81
New cards

T/F: Noise and low contrast resolution can be evaluated utilizing the Leeds TO.12 phantom.

true

82
New cards

SMPTE is an acronym meaning this:

Society of Motion Picture and Television Engineers

3 multiple choice options

83
New cards

it is recommended that PSP plates be erased every __ hours if it has not been used

48

3 multiple choice options

84
New cards

T/F: to ensure consistency among image appearance, all systems within a facility should use identical processing codes

true

85
New cards

Types of monitors include all of the following EXCEPT:

DEL's

3 multiple choice options

86
New cards

this term refers to the number of pixels in a matrix and the size of the display screen.

spatial resolution

3 multiple choice options

87
New cards

CRT monitors typically have an aspect ratio of ___

4:3

3 multiple choice options

88
New cards

The _______ the bit depth, the _______ the range of color values that can be displayed

greater, greater

3 multiple choice options

89
New cards

the measurement from the center of one pixel to the center of the next is called:

pixel pitch

3 multiple choice options

90
New cards

regarding modality work list, HIS stands for this:

Hospital Information System

3 multiple choice options

91
New cards

T/F: PACS is a computer-based storage, retrieval and viewing system for digital imaging systems

true

92
New cards

PACS is an acronym that stands for:

Picture Archiving and Communication System

3 multiple choice options

93
New cards

this standard ensures adaptability between different imaging systems

DICOM

3 multiple choice options

94
New cards

another digital communication standard that sets rules for transmitting text-based patient information

HL7

3 multiple choice options

95
New cards

RAID is considered this type of storage device:

near-term

3 multiple choice options

96
New cards

this storage device is the largest device available

jukebox

3 multiple choice options

97
New cards

T/F: the jukebox is utilized as near-term storage

false

98
New cards

this process of remote transmission and viewing of images is called:

teleradiology

3 multiple choice options

99
New cards

Night hawking is a term used to refer to this:

off-site reading by radiologist not employed by the hospital

3 multiple choice options

100
New cards

When should the exported data from digital images be anonymized?

- if part of medical research

- if used for educational purposes