Image Production - Chapter 10

0.0(0)
Studied by 0 people
call kaiCall Kai
Locked
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/80

flashcard set

Earn XP

Description and Tags

Digital Image Receptors

Last updated 8:03 PM on 9/20/26
Name
Mastery
Learn
Test
Matching
Spaced
Call with Kai
Chat

No analytics yet

Send a link to your students to track their progress

81 Terms

1
New cards

Systems that use storage phosphors to temporarily store energy representing the image signal are called

Computed Radiography (CR)

2
New cards

Systems that have detectors that directly or indirectly capture and read out an electronic image signal are called

Digital Radiography (DR)

3
New cards

How do DR systems work?

The image-forming radiation is captured and transferred to a computer from the detector array for viewing at the control panel

4
New cards

The physical component consisting of multiple detectors that efficiently absorb the transmitted radiation and accurately convert it to an electrical signal for display on a computer workstation is a

Detector Array

5
New cards

What are the 2 different types of Indirect Capture?

Charge-Coupled Device (CCD)

Thin Film Transistor (TFT)

6
New cards

Which type of indirect capture uses a light-sensitive semiconducting device that generates an electrical charge when stimulated by light and stores this charge in a capacitor?

Charge-Coupled Device -CCD

7
New cards

Which type of indirect capture uses electrical components layered onto a glass substrate that includes the readout, charge collector and light-sensitive elements?

Thin Film Transistor (TFT)

8
New cards

A material that absorbs x-ray energy and emits visible light in response

Scintillator

9
New cards

A process in which several CCD detectors abut (touch) to create one larger detector

Tiling

10
New cards

True or False: Tiling is a major advantage of CCDs

False - disadvantage because it results in seams with unequal response

11
New cards

True or False: Indirect Capture methods result in higher resolution

False - loss of resolution

12
New cards

True or False: Gadolinium Oxysulfide spreads significantly more light than Cesium Iodide

True

13
New cards

What is the photodiode layer made of on the thin film transistor array?

Amorphous Silicon

14
New cards

What is the photodiode layer (photoconductor) made of in the direct capture method?

Amorphous Selenium

15
New cards

What is the main difference between Indirect and Direct capture methods?

Direct capture does not use a scintillator; it directly converts x-rays into an electrical signal

16
New cards

A graphic representation of a data set is called; Represents the number of digital pixel values versus the relative prevalence of those values in the image

Histogram

17
New cards

Which axis of the histogram represents the amount of exposure

The X axis

18
New cards

Which axis of the histogram represents the incidence of pixels for each exposure level?

The Y axis

19
New cards

A process in which a computer analyzes the histogram using processing algorithms and compares it to a preestablished histogram specific to the anatomic part being imaged

Histogram Analysis

20
New cards

Established values within histogram models that determine what part of the data set should be incorporated into the displayed image

Values of Interest (VOI)

21
New cards

What is it called when the computer adjusts the image based on the comparison of the histograms and corrects for “over or under exposure”; a process of mapping the grayscale to the VOI to present a specific display of brightness

Rescaling

22
New cards

True or False: With these systems, only those detector pixels that received x-ray exposure contribute to the image

True

23
New cards

True or False: With digital receptors, the response to exposure is nonlinear and the range of exposures is limited

False - response to exposure is linear and range of exposures is wide (wide dynamic range)

24
New cards

The range of exposure intensities that an image receptor can respond to and use to acquire image data is called

Dynamic Range

25
New cards

The range of exposures that produce acceptable images and information within an acceptable radiation dose to the patient is called

Exposure Latitude

26
New cards

Primary Display workstations are

used for official interpretation of images; Radiologist work stations

27
New cards

List the guidelines for primary workstations

Max. Luminance levels of at least 171 cd/m2

Contrast response that meets the standards of the Association of Physicists in Medicine

A minimum of 8-bit luminance resolution

Minimal veiling glare

Minimizing reflections from and levels of ambient light sources

28
New cards

What do postprocessing functions allow for?

Manual manipulation of the displayed image

29
New cards

True or False: Digital radiography uses a 6-bit dynamic range?

False - 14

30
New cards

How many shades of gray can the human eye see?

30

31
New cards

In CR systems, Fuji, Philips, and Konica use ______ numbers, and the value is _____ related to the exposure to the plate

Sensitivity (S); inversely

32
New cards

Carestream (Kodak) uses ___ numbers, and the value is _____ related to the exposure to the plate and the changes are ______ expressions.

EI (exposure index); directly related; logarithmic expressions

33
New cards

Agfa uses _____ numbers; the value is _____ related and changes are ____ expressions

log mean (lgM) numbers; directly related; logarithmic expressions;

34
New cards

What do DR systems use as an indicator of exposure?

DAP - dose-are product

35
New cards

A measure of exposure in air, followed by computation to estimate absorbed dose to the patient

Dose-area product (DAP)

36
New cards

True or False: DAP reflects both the dose to the patient and the total volume of tissue being irradiated

True

37
New cards

What is DAP measured by?

a dose meter in the collimator

38
New cards

What does the DAP value depend on and how is it expressed?

Depends on the exposure factors and field size and is expressed in centigray-meter squared

39
New cards

Represents the exposure at the detector relevant to the region being imaged and is defined by the signal-to-noise ratio

EI

40
New cards

The target reference exposure obtained from a properly exposed image receptor

Target Exposure Index

41
New cards

A measure of the deviation of the EI from projection-specific target EI values

Deviation Index

42
New cards

Which value indicates to the radiographer that proper exposure is taking place for the body part being examined by indicating above or below the ideal value determined for that part

Deviation Index

43
New cards

An expression of the radiation exposure level that is required to produce an optimal image; a measurement of the efficiency of an IR in converting the x-ray exposure it receives to a quality radiographic image

Detective Quantum Efficiency DQE

44
New cards

True or False: The lower the DQE, the lower the radiation exposure required to produce a quality image, thereby decreasing patient dose

False - the Higher the DQE

45
New cards

What happens to the image if the DQE is too high?

It results in a noisy (grainy) image because not enough photons are hitting the IR

46
New cards

An expression of how clearly a very faint object appears in the image

SNR

47
New cards

True or False: DQE is a measure of how well the SNR is preserved in an image

True

48
New cards

Any undesired fluctuation in the brightness of an image is

Image Noise (quantum noise plus the electronic components of digital imaging systems)

49
New cards

____ ___ is defined as equal to ½ the Nyquist Frequency

Spatial Resolution

50
New cards

The highest spatial frequency (number of line pairs per mm) that a digital detector can record and is determined by the sampling frequency of CR systems and the DEL spacing of DR systems

Nyquist Frequency

51
New cards

What are the 2 measures of Spatial Resolution?

Limiting Spatial Resolution (LSR)

Modulation Transfer Function (MTF)

52
New cards

The ability of a detector to resolve small structures and is measured using a bar pattern

Limiting Spatial Resolution

53
New cards

LSR is limited by

the number of pixels and pixel size

54
New cards

True or False: MTF is not as accurate as LSR

False - LSR is not as accurate as MTF because it depends on the contrast of the target and the exposure and display conditions

55
New cards

A measure of the ability of the system to preserve signal contrast (display the contrast of anatomic objects varying in size) as a function of spatial resolution and describes the fraction of each component that preserves the captured image

Modulation transfer function (MTF)

56
New cards

Which method is considered to be the ideal expression of digital detector image resolution?

MTF

57
New cards

What is the primary factor influencing radiographic contrast with digital systems?

The Lookup Table (LUT)

58
New cards

Histograms of luminance values used as a reference to evaluate the input intensities and assign predetermined grayscale values - VOI

Lookup Tables (LUTs)

59
New cards

At what stage does rescaling occur?

at the Lookup Table

60
New cards

The adjusting of the image by the computer program to present an image of predetermined brightness is called

Rescaling

61
New cards

True or False: Digital receptors are less sensitive to low energy radiation

False - more sensitive

62
New cards

What 2 ways can you effectively control scatter radiation’s effect on the image?

Collimation

Grid Use

63
New cards

How many test patterns can be used to assess display device performance?

26

64
New cards

This test looks at general image quality and for the presence of artifacts

Overall visual assessment TG18-QC

65
New cards

This test checks for a variation in the shape of the displayed image from the original image

Geometric Distortion

66
New cards

This test evaluates the ambient light contribution to the light reflected by the display monitor

Reflection TG18-AD

67
New cards

This test assesses the displayed luminance values versus the input values from the display system

Luminance Response

68
New cards

This test evaluates the image for nonuniformity and effects of viewing different angles

Luminance Dependencies

69
New cards

This test assesses the systems ability to display images of different parts of an image with high fidelity

Resolution

70
New cards

What is the average size of a digital radiography study?

38 MB

71
New cards

An electronic network for communication between the image acquisition modalities, display stations and storage

Picture Archiving and Communication System (PACS)

72
New cards

A common language used by different systems for communication

Digital Imaging and Communication in Medicine (DICOM)

73
New cards

A PACS system consists of

Acquisition (imaging modalities)

Display (viewing and workstations)

Storage (archive server)

74
New cards

A 1-megapixel monitor is sufficient for ….

A 2-megapixel monitor is sufficient for…

A 5-megapixel monitor is sufficient for …

1 - general viewing by non-interpreting physicians

2 - general interpretation by a radiologist

5 - interpretation of digital mammograms

75
New cards

What are the challenges of PACS

Storage of data over decades

Expansion and maintenance

changes in vendors

76
New cards

True or False: Vendor neutral archives (VNAs) allow for images and data from different systems and in different formats to be stored using a singular system on common infrastructure

True

77
New cards

The component of PACS that handles the workflow of the system moving images back and forth between viewing stations

Image Manager

78
New cards

Storage is classified as

Online

Nearline

Offline

79
New cards

Data are stored on magnetic hard drives with access times in milliseconds and transfer times in range of tens and hundreds of megabytes per second

Online

80
New cards

A tape or jukebox uses robotic arms to retrieve the tapes automatically and insert them into a drive to read or write data; can access data within 60 seconds and is able to transfer data at a few megabytes per second

Nearline

81
New cards

A removable tape or optical media will be stored on a shelf in a catalog and retrieved manually

Offline