The dead time or resolving time of the Geiger tube refers to the time during which :

no radiation is detected

3 multiple choice options

2
New cards

Which of the following is correct about this image?

This is an ionization chamber

3 multiple choice options

3
New cards

What would be the correct reading if the needle is pointing to 0.8 and the meter is set to X 0.1?

0.08

3 multiple choice options

4
New cards

A dose calibrator is being tested for accuracy. The expected reading is 75 uCi. The dose calibrator reads 68 uCi. What should the technologist do?

Document this value, it is a passing result

3 multiple choice options

5
New cards

Which of the following sources should NOT be used for a constancy test?

I-123

3 multiple choice options

6
New cards

Accuracy determines if your dose calibrator can find the true value. What does constancy test?

Precision

3 multiple choice options

7
New cards

A geometry test was performed. The expected reading was 2.95 mCi. The actual reading was 2.45 mCi. What correction factor should be applied?

1.2

3 multiple choice options

8
New cards

A linearity test on a dose calibrator should be performed using the highest activity that will be used in the department. How long should it be carried out if using Tc-99m?

Until it reaches 30 uCi

3 multiple choice options

9
New cards

What is the cause of the peak being out of the window in c, d, and f?

The high voltage has drifted

3 multiple choice options

10
New cards

Your well counter has an efficiency of 85%. You count a wipe and get 120 cpm with a background of 2. How do you report this result?

139 dpm

3 multiple choice options

11
New cards

A 0.2 uCi Cs-137 stick is calculated to be 7,400 Becquerels. Cs-137 has an 85% abundance at 662 keV. The well counter reads the stick as 158,000 cpm. What is the well counter efficiency?

42%

3 multiple choice options

12
New cards

What is the purpose of a collimator on a gamma camera?

To absorb photons enerting at an angle

3 multiple choice options

13
New cards

A four-quadrant bar phantom is used for spatial resolution and what other quality control test?

Linearity

3 multiple choice options

14
New cards

How many counts should be collected in a daily uniformity test?

5-15 million

3 multiple choice options

15
New cards

An integral uniformity test is performed on a daily flood. The maximum pixel count was 7498 and the minimum pixel count was 7216. What is the integral uniformity?

1.92%

3 multiple choice options

16
New cards

A line source is being used to evaluate spatial resolution. How would the graph be used to quantify the spatial resolution of the camera?

the FWHM

3 multiple choice options

17
New cards

This phantom can evaluate each of the following EXCEPT?

Linearity

3 multiple choice options

18
New cards

A small petri dish of activity placed on the camera has 83 cps/MBq. What is being evaluated?

Sensitivty

3 multiple choice options

19
New cards

How many pixels are in a 64×64 matrix?

4096

3 multiple choice options

20
New cards

An energy resolution test using Tc-99m is being conducted on a gamma camera. The FWHM is 17. What is the percent energy resolution?

12%

3 multiple choice options

21
New cards

If your FOV is 380 mm, what are the size of your pixels if you are using a 128x128 matrix?

2.97 mm

3 multiple choice options

22
New cards

You want to collect 3,000,000 in your SPECT study. Your count rate is 200,000 cpm. You have a single head camera and plan to do 64 stops. How many seconds per stop are needed?

14 seconds

3 multiple choice options

23
New cards

What type of coincidence is depicted below?

Scatter

3 multiple choice options

24
New cards

What are two sources of error in PET imaging that we cannot correct for?

Non-colinearity and Randoms

3 multiple choice options

25
New cards

A Co-57 source is going to be used for an accuracy test. One year ago, it had 2.5 mCi. What is the expected activity today?

0.98 mCi

3 multiple choice options

26
New cards

Why is Cs-137 used for constancy and accuracy testing?

It has a long half life

3 multiple choice options

27
New cards

According to nationally recognized standards, how often should a dose calibrator undergo linearity testing (in addition to installation and after repairs)?

Quarterly

3 multiple choice options

28
New cards

A linearity test can be performed using time (decay). What other method can be used in a linearity test?

Shielding

3 multiple choice options

29
New cards

This image is useful in identifying motion. What is this image called?

Sinogram

3 multiple choice options

30
New cards

Which of the following converts light into electrons?

Photocathode

3 multiple choice options