Oxygen Delivery Devices & Systems Flashcards

0.0(0)
Studied by 0 people
call kaiCall Kai
Locked
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/21

flashcard set

Earn XP

Description and Tags

Flashcards covering low-flow and high-flow oxygen delivery systems, safety alerts, flow rates, FiO2 ranges, and clinical indications based on Sole's Introduction to Critical Care Nursing (9th Ed.).

Last updated 3:19 AM on 9/22/26
Name
Mastery
Learn
Test
Matching
Spaced
Call with Kai
Chat

No analytics yet

Send a link to your students to track their progress

22 Terms

1
New cards

What is the primary clinical purpose of administering supplemental oxygen?

Supplemental oxygen is administered to prevent or treat hypoxemia.

2
New cards

How are oxygen delivery systems broadly classified, and what is the basis for this classification?

Oxygen delivery systems are broadly classified into low-flow and high-flow systems based on whether the gas flow meets the patient's full inspiratory demand.

3
New cards

What defines a low-flow oxygen delivery system?

Low-flow systems deliver oxygen at flow rates less than the patient's total inspiratory demand, causing the patient to entrain ambient room air and resulting in variable FiO2 based on respiratory rate, tidal volume, and ventilatory pattern.

4
New cards

What are the flow rate and delivered FiO2 range for a standard nasal cannula?

The flow rate is 1−6 L/min1 - 6\,\text{L/min} and the delivered FiO2 ranges from 24%24\% to 44%44\%.

5
New cards

According to the rule of thumb for a nasal cannula, how much does each 1 L/min1\,\text{L/min} increase in flow raise the delivered FiO2?

Each 1 L/min1\,\text{L/min} increase adds approximately 4%4\% to FiO2 (1 L/min≈24%1\,\text{L/min} \approx 24\%, 2 L/min≈28%2\,\text{L/min} \approx 28\%, 3 L/min≈32%3\,\text{L/min} \approx 32\%).

6
New cards

Why should oxygen flow rates via a nasal cannula not exceed 6 L/min6\,\text{L/min}?

Flow rates greater than 6 L/min6\,\text{L/min} exceed anatomical nasopharyngeal reservoir capacity and dry mucosa without providing additional benefit.

7
New cards

What is the primary nursing priority regarding skin inspection for a patient on a nasal cannula?

Inspect the nares and skin behind/above ears regularly for pressure breakdown.

8
New cards

What are the flow rate and FiO2 parameters for a Simple Face Mask?

The flow rate is 5−12 L/min5 - 12\,\text{L/min} and the FiO2 ranges from 30%30\% to 60%60\%.

9
New cards

What critical safety rule must be followed when setting the flow meter for a Simple Face Mask, and why?

The flow meter must be set to at least 5 L/min5\,\text{L/min} to flush exhaled CO2\text{CO}_2 from the mask and prevent rebreathing.

10
New cards

How should the flow rate be titrated for a Partial-Rebreather Mask?

Set the flow meter so that the reservoir bag deflates no more than one-half (<50%< 50\%) during inspiration.

11
New cards

What are the flow rate and FiO2 parameters for a Non-Rebreather Mask?

The flow rate is 10−15 L/min10 - 15\,\text{L/min} and the FiO2 ranges from 60%60\% to 80%80\% (up to 100%100\% in codes).

12
New cards

What is the function of the one-way valves on a Non-Rebreather Mask?

One-way valves located between the mask and reservoir bag, and over the exhalation port, prevent rebreathing of room air or CO2\text{CO}_2.

13
New cards

What defines a high-flow oxygen delivery system?

High-flow systems supply gas at flow rates that meet or exceed total inspiratory demand, delivering a precise and consistent FiO2 regardless of breathing pattern.

14
New cards

How does a Venturi (air-entrainment) mask deliver fixed FiO2 concentrations?

It uses color-coded jet adapters operating on the Bernoulli principle to entrain specific ratios of room air.

15
New cards

Why is the Venturi mask considered the choice device for hypoxemic COPD patients?

It delivers a highly accurate, fixed FiO2, preventing excess oxygen from suppressing the patient's hypoxic respiratory drive.

16
New cards

What specific fixed FiO2 levels can be delivered using a Venturi mask?

The Venturi mask delivers fixed FiO2 values of 24%24\%, 28%28\%, 31%31\%, 35%35\%, and 40%40\%.

17
New cards

What safety alert must nurses maintain regarding the physical setup of a Venturi mask?

Ensure that entrainment ports remain unobstructed by bed linens or clothing.

18
New cards

What are the flow rate and FiO2 capabilities of a High-Flow Nasal Cannula (HFNC)?

The flow rate ranges from 1515 to 60 L/min60\,\text{L/min} and the FiO2 ranges from 60%60\% to 90%+90\%+.

19
New cards

What physiological effects are produced by a High-Flow Nasal Cannula (HFNC)?

It delivers heated and fully humidified gas, generates low PEEP (approximately 1 cm H2O1\,\text{cm H}_2\text{O} per 10 L/min10\,\text{L/min} flow), flushes upper airway CO2\text{CO}_2 dead-space, and significantly reduces work of breathing.

20
New cards

When is aerosol therapy indicated for oxygen administration?

Aerosol therapy is indicated to prevent mucosal drying when flow rates exceed 4 L/min4\,\text{L/min} or when artificial airways bypass natural upper respiratory tract humidification.

21
New cards

How should an aerosol mask or T-piece delivery system be set up and adjusted?

Set the initial flow rate at 10 L/min10\,\text{L/min} and adjust it so that a constant mist is visible from the exhalation port.

22
New cards

What flow rate and equipment setup are required for a Manual Resuscitation Bag (BVM) to deliver 100%100\% FiO2?

It must be attached to a 15 L/min15\,\text{L/min} oxygen source with an attached oxygen reservoir.