Flashcards covering low-flow and high-flow oxygen delivery systems, safety alerts, flow rates, FiO2 ranges, and clinical indications based on Sole's Introduction to Critical Care Nursing (9th Ed.).
Name | Mastery | Learn | Test | Matching | Spaced | Call with Kai | Chat |
|---|
No analytics yet
Send a link to your students to track their progress
What is the primary clinical purpose of administering supplemental oxygen?
Supplemental oxygen is administered to prevent or treat hypoxemia.
How are oxygen delivery systems broadly classified, and what is the basis for this classification?
Oxygen delivery systems are broadly classified into low-flow and high-flow systems based on whether the gas flow meets the patient's full inspiratory demand.
What defines a low-flow oxygen delivery system?
Low-flow systems deliver oxygen at flow rates less than the patient's total inspiratory demand, causing the patient to entrain ambient room air and resulting in variable FiO2 based on respiratory rate, tidal volume, and ventilatory pattern.
What are the flow rate and delivered FiO2 range for a standard nasal cannula?
The flow rate is 1−6L/min and the delivered FiO2 ranges from 24% to 44%.
According to the rule of thumb for a nasal cannula, how much does each 1L/min increase in flow raise the delivered FiO2?
Each 1L/min increase adds approximately 4% to FiO2 (1L/min≈24%, 2L/min≈28%, 3L/min≈32%).
Why should oxygen flow rates via a nasal cannula not exceed 6L/min?
Flow rates greater than 6L/min exceed anatomical nasopharyngeal reservoir capacity and dry mucosa without providing additional benefit.
What is the primary nursing priority regarding skin inspection for a patient on a nasal cannula?
Inspect the nares and skin behind/above ears regularly for pressure breakdown.
What are the flow rate and FiO2 parameters for a Simple Face Mask?
The flow rate is 5−12L/min and the FiO2 ranges from 30% to 60%.
What critical safety rule must be followed when setting the flow meter for a Simple Face Mask, and why?
The flow meter must be set to at least 5L/min to flush exhaled CO2 from the mask and prevent rebreathing.
How should the flow rate be titrated for a Partial-Rebreather Mask?
Set the flow meter so that the reservoir bag deflates no more than one-half (<50%) during inspiration.
What are the flow rate and FiO2 parameters for a Non-Rebreather Mask?
The flow rate is 10−15L/min and the FiO2 ranges from 60% to 80% (up to 100% in codes).
What is the function of the one-way valves on a Non-Rebreather Mask?
One-way valves located between the mask and reservoir bag, and over the exhalation port, prevent rebreathing of room air or CO2.
What defines a high-flow oxygen delivery system?
High-flow systems supply gas at flow rates that meet or exceed total inspiratory demand, delivering a precise and consistent FiO2 regardless of breathing pattern.
How does a Venturi (air-entrainment) mask deliver fixed FiO2 concentrations?
It uses color-coded jet adapters operating on the Bernoulli principle to entrain specific ratios of room air.
Why is the Venturi mask considered the choice device for hypoxemic COPD patients?
It delivers a highly accurate, fixed FiO2, preventing excess oxygen from suppressing the patient's hypoxic respiratory drive.
What specific fixed FiO2 levels can be delivered using a Venturi mask?
The Venturi mask delivers fixed FiO2 values of 24%, 28%, 31%, 35%, and 40%.
What safety alert must nurses maintain regarding the physical setup of a Venturi mask?
Ensure that entrainment ports remain unobstructed by bed linens or clothing.
What are the flow rate and FiO2 capabilities of a High-Flow Nasal Cannula (HFNC)?
The flow rate ranges from 15 to 60L/min and the FiO2 ranges from 60% to 90%+.
What physiological effects are produced by a High-Flow Nasal Cannula (HFNC)?
It delivers heated and fully humidified gas, generates low PEEP (approximately 1cm H2O per 10L/min flow), flushes upper airway CO2 dead-space, and significantly reduces work of breathing.
When is aerosol therapy indicated for oxygen administration?
Aerosol therapy is indicated to prevent mucosal drying when flow rates exceed 4L/min or when artificial airways bypass natural upper respiratory tract humidification.
How should an aerosol mask or T-piece delivery system be set up and adjusted?
Set the initial flow rate at 10L/min and adjust it so that a constant mist is visible from the exhalation port.
What flow rate and equipment setup are required for a Manual Resuscitation Bag (BVM) to deliver 100% FiO2?