1/13
Looks like no tags are added yet.
Name | Mastery | Learn | Test | Matching | Spaced | Call with Kai | Chat |
|---|
No analytics yet
Send a link to your students to track their progress
between kVp ranging from 55-85, every 1 kVp =
10% radiation intensity increase
10 kVp = 100%
doubling mAs =
doubling dose/intensity
how to double kVp
increasing it by 15% (kVp x 1.15)
every 5cm part thickness change requires a
100% increase or 50% decrease in radiation
For SID changes adjust…
mAs, as SID has no effect on kVP
Every ~50 cm SID change =
2/1 or 1/2 Rad
Every ~25 cm SID change =
3/2 or 2/3 Rad
Grid Ratio and GCF

Fugi
EI name
acceptance range
change of 100%
relation to acceptance numbers
S#
100-250
doubel or half S#
inverse
Carestream
EI
1800-2200
+-300 of EI
direct
Phillips (old)
EI
350-600
each step of EI reflects a 25% change
inverse
Phillips (new)
EXI
125-500
doubel or half EXI
direct
patient size increases but same body part?
if the kVp is at the top of the range, increase mAs
if the kVp isn’t at the top, use split technique
Additive and Destructive diseases → check on LH